Learn how to safely operate GC columns at high temperatures. Discover the effects of overheating, key temperature limits, and why Zebron™ and Inferno™ columns offer superior thermal stability.
We, 12.11.2025
Phenomenex
Article | Academy
Using Phase Ratio to Reduce Run Time
Learn how column length, internal diameter, and film thickness work together to optimize phase ratio in GC. Discover how adjusting these parameters reduces run time while maintaining separation efficiency.
We, 5.11.2025
Phenomenex
Article | Academy
GC Technical Tip: Retention Times Prolonged or Shortened
Learn how to diagnose and fix retention time shifts in GC. This guide explains common column performance issues, their causes, and practical remedies for consistent chromatographic results.
We, 29.10.2025
Phenomenex
Article | Academy
Good Column Selection: Polarity vs Selectivity
Understanding GC column polarity and selectivity is key to achieving optimal separations. Learn how to choose the right stationary phase for your compounds and improve chromatographic performance.
We, 22.10.2025
Phenomenex
Article | Academy
Phenomenex technical tip for Baseline problems - offset
Learn how to fix baseline offset in gas chromatography. Identify causes like voltage changes, contamination, or gas flow issues and apply targeted maintenance for stable results.
We, 15.10.2025
Phenomenex
Article | Academy
Peak Shape Problems in Gas Chromatography
Negative peaks in GC can affect your analysis accuracy. Learn about the main causes, from detector overload to contamination, and how to correct them effectively.
We, 8.10.2025
Phenomenex
Article | Academy
Peak Shape Problems: Sensitivity Loss
Learn how to identify and fix sensitivity loss in GC. Discover key causes, from column contamination to injector leaks, and apply remedies for reliable, accurate results.
We, 1.10.2025
Phenomenex
Article | Academy
I am getting low recovery in my SPE method, how do I fix the problem?
Practical troubleshooting guide for low recovery in SPE methods. Learn how to identify problems with solvents, flow rate, pH, or sorbent choice step by step.
We, 17.9.2025
Phenomenex
Article | Academy
Over-Drying of Silica-Based SPE Cartridges Can Lead to Poor Sample Recovery
Over-drying silica-based SPE cartridges during conditioning can reduce analyte retention and recovery. Learn best practices to avoid losses and ensure reproducible results.
We, 3.9.2025
Phenomenex
Article | Academy
Peak Shape Problems: No Peaks
Missing peaks in GC runs? This technical tip reviews key causes like syringe, inlet, detector, or column issues, with practical solutions to restore results.