Base neutrals
Applications | 2011 | Agilent TechnologiesInstrumentation
GC/MSD, GC columns, Consumables
IndustriesEnvironmental
ManufacturerAgilent Technologies
Key wordsneutrals, courtesy, base, printed, injector, usa, authors, size, program, environmental, technique, identification, carrier, pressure, solvent, detector, note, temperature, peak, conditions, gas, application, introduction, column, sample
Similar PDF
Base neutrals - Base neutrals to EPA 8270
2011|Agilent Technologies|Applications
Base neutrals Base neutrals to EPA 8270 Application Note Environmental Authors Introduction Agilent Technologies, Inc. Using GC/MS, an Agilent FactorFour VF-200ms column separates 13 base neutrals according to EPA8270 in 20 minutes. Conditions Technique : GC Column : Agilent FactorFour…
Key words
neutrals, neutralscourtesy, courtesybase, baseprinted, printedinjector, injectorusa, usaauthors, authorssize, sizeprogram, programenvironmental, environmentaltechnique, techniqueidentification, identificationcarrier, carrierpressure, pressuresolvent
Nitro- and chlorinated aromatics - Separation of nitro-and halogenated aromatic compounds (base neutrals)
2011|Agilent Technologies|Applications
Nitro- and chlorinated aromatics Separation of nitro-and halogenated aromatic compounds (base neutrals) Application Note Environmental Authors Introduction Agilent Technologies, Inc. Separation of 14 nitro-and halogenated aromatic compounds (base neutrals) by Agilent VF-1701ms in 20 minutes. Conditions Technique : GC-capillary Column…
Key words
nitro, nitroneutrals, neutralshalogenated, halogenatedaromatics, aromaticschlorinated, chlorinatedcourtesy, courtesyaromatic, aromaticbase, baseprinted, printedinjector, injectorusa, usaauthors, authorssize, sizeenvironmental, environmentaltechnique
Base neutrals
2011|Agilent Technologies|Applications
Base neutrals Application Note Environmental Authors Introduction Agilent Technologies, Inc. Analysis of 14 halogenated base neutrals using Agilent FactorFour VF-1301ms in 22 minutes. Conditions Technique : GC-capillary Column : Agilent FactorFour VF-1301ms, 0.25 mm x 30 m fused silica (df…
Key words
neutrals, neutralscourtesy, courtesybase, baseprinted, printedinjector, injectorusa, usaauthors, authorsenvironmental, environmentaltechnique, techniquecarrier, carrieridentification, identificationdetector, detectornote, notetemperature, temperaturepeak
GC Analysis of Basic and Neutral Compounds on Agilent J&W FactorFour VF-35ms with EZ-Guard
2010|Agilent Technologies|Applications
GC Analysis of Basic and Neutral Compounds on Agilent J&W FactorFour VF-35ms with EZ-Guard Application Note Author Introduction Peter Heijnsdijk Agilent Technologies, Inc. Contamination from complex matrices can reduce column lifetimes and increase costs. The remedy is to use an…
Key words
neutral, neutralmulticomponent, multicomponentbasic, basicheijnsdijk, heijnsdijklifetime, lifetimefactorfour, factorfourcontamination, contaminationmanufactures, manufacturescolumn, columnpeter, peterlifetimes, lifetimesvolatility, volatilityuptime, uptimeextends, extendsmethylene