Base neutrals
Applications | 2011 | Agilent TechnologiesInstrumentation
In environmental monitoring, base neutrals represent a class of halogenated compounds that can pose significant ecological and health risks. Accurate and efficient analysis of these species is essential for compliance with regulatory standards and for assessing pollution levels in various matrices.
This application note demonstrates a rapid gas chromatographic method for the separation and detection of fourteen halogenated base neutral compounds in under twenty two minutes. The focus lies on method optimization using a high resolution capillary column to achieve complete resolution of target analytes.
All fourteen halogenated base neutral compounds, including various dichlorobenzenes, trichlorobenzenes, hexachlorinated species and nitro and azo compounds, were separated with baseline resolution within a twenty two minute analysis time. The retention order reflected increasing molecular weight and halogen substitution pattern. Peak shapes indicated efficient interaction with stationary phase and minimal tailing.
Advancements may focus on integration with mass selective detectors for improved sensitivity and selectivity, development of novel stationary phases for challenging compound classes and miniaturized systems for field deployable analysis.
The presented method using a high performance capillary column delivers fast and reliable separation of a diverse set of base neutral analytes, meeting the demands of environmental laboratories for efficiency and accuracy.
GC, GC columns, Consumables
IndustriesEnvironmental
ManufacturerAgilent Technologies
Summary
Importance of base neutral analysis
In environmental monitoring, base neutrals represent a class of halogenated compounds that can pose significant ecological and health risks. Accurate and efficient analysis of these species is essential for compliance with regulatory standards and for assessing pollution levels in various matrices.
Objectives and study overview
This application note demonstrates a rapid gas chromatographic method for the separation and detection of fourteen halogenated base neutral compounds in under twenty two minutes. The focus lies on method optimization using a high resolution capillary column to achieve complete resolution of target analytes.
Methodology
- Capillary gas chromatography technique
- Temperature program starting at 45 C with three minute initial hold followed by ten C per minute ramp to 280 C
- Injector split mode with one microliter injection volume and split ratio of one hundred to one
- Carrier gas helium at sixty kilo pascal
Instrumentation
- Gas chromatograph equipped with a high efficiency capillary column of thirty meter length, quarter millimeter internal diameter and film thickness of zero point twenty five micrometer
- Flame ionization detector for compound detection
Main results and discussion
All fourteen halogenated base neutral compounds, including various dichlorobenzenes, trichlorobenzenes, hexachlorinated species and nitro and azo compounds, were separated with baseline resolution within a twenty two minute analysis time. The retention order reflected increasing molecular weight and halogen substitution pattern. Peak shapes indicated efficient interaction with stationary phase and minimal tailing.
Benefits and practical applications
- High throughput screening of environmental samples for halogenated base neutrals
- Enhanced method robustness and reproducibility suitable for routine laboratory use
- Reduced analysis time supports increased sample throughput and lower per sample cost
Future trends and opportunities
Advancements may focus on integration with mass selective detectors for improved sensitivity and selectivity, development of novel stationary phases for challenging compound classes and miniaturized systems for field deployable analysis.
Conclusion
The presented method using a high performance capillary column delivers fast and reliable separation of a diverse set of base neutral analytes, meeting the demands of environmental laboratories for efficiency and accuracy.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Nitro- and chlorinated aromatics - Separation of nitro-and halogenated aromatic compounds (base neutrals)
2011|Agilent Technologies|Applications
Nitro- and chlorinated aromatics Separation of nitro-and halogenated aromatic compounds (base neutrals) Application Note Environmental Authors Introduction Agilent Technologies, Inc. Separation of 14 nitro-and halogenated aromatic compounds (base neutrals) by Agilent VF-1701ms in 20 minutes. Conditions Technique : GC-capillary Column…
Key words
nitro, nitroneutrals, neutralshalogenated, halogenatedaromatics, aromaticschlorinated, chlorinatedcourtesy, courtesyaromatic, aromaticbase, baseprinted, printedinjector, injectorusa, usaauthors, authorsenvironmental, environmentalsize, sizetechnique
Base neutrals
2011|Agilent Technologies|Applications
Base neutrals Application Note Environmental Authors Introduction Agilent Technologies, Inc. Using GC/MS, an Agilent FactorFour VF-200ms column separates 14 base neutrals in 20 minutes. Conditions Technique : GC Column : Agilent FactorFour VF-200ms, 0.25mm x 30 m (df = 1.0…
Key words
neutrals, neutralscourtesy, courtesybase, baseprinted, printedinjector, injectorusa, usaauthors, authorsprogram, programenvironmental, environmentalsize, sizetechnique, techniquecarrier, carrieridentification, identificationpressure, pressuresolvent
Base neutrals
2011|Agilent Technologies|Applications
Base neutrals Application Note Environmental Authors Introduction Agilent Technologies, Inc. Analysis of 14 base neutrals by gas chromatography using an Agilent FactorFour VF-1301ms column in less than 40 minutes. Conditions Technique : GC-capillary Column : Agilent FactorFour VF-1301ms, 0.25 mm…
Key words
neutrals, neutralscourtesy, courtesybase, baseprinted, printedinjector, injectorusa, usaauthors, authorsenvironmental, environmentaltechnique, techniquecarrier, carrieridentification, identificationdetector, detectornote, notepeak, peaktemperature
GC Analysis of Basic and Neutral Compounds on Agilent J&W FactorFour VF-35ms with EZ-Guard
2010|Agilent Technologies|Applications
GC Analysis of Basic and Neutral Compounds on Agilent J&W FactorFour VF-35ms with EZ-Guard Application Note Author Introduction Peter Heijnsdijk Agilent Technologies, Inc. Contamination from complex matrices can reduce column lifetimes and increase costs. The remedy is to use an…
Key words
neutral, neutralmulticomponent, multicomponentbasic, basicheijnsdijk, heijnsdijklifetime, lifetimefactorfour, factorfourcontamination, contaminationcolumn, columnmanufactures, manufacturespeter, peterlifetimes, lifetimesvolatility, volatilityextends, extendsuptime, uptimemethylene