Summary

Significance of the Topic


Phenolic compounds are prevalent in industrial effluents, environmental samples, and consumer products. Due to their toxicity and strict regulatory limits, sensitive and reliable analytical methods are essential. GC–MS offers high selectivity and resolution for complex phenolic mixtures, making it a key tool in environmental monitoring, quality control, and research.

Objectives and Study Overview


This application note demonstrates a method for separating and detecting 17 phenolic derivatives using a BPX35 capillary column. The study evaluates chromatographic and mass spectrometric parameters to establish a robust protocol for routine analysis.

Methodology and Instrumentation


  • Sample: 200 ppm phenolic mixture in methanol; injection volume 1 µL (split 100:1).
  • Column: BPX35, 30 m × 0.25 mm × 0.25 µm film thickness; helium carrier gas at 1.7 mL/min (constant flow).
  • Temperature program: 80 °C hold for 1 min, ramp at 10 °C/min to 300 °C, hold for 5 min.
  • Injection temperature: 250 °C; liner: 4 mm ID single taper.
  • Detection: mass spectrometer in full-scan mode (m/z 45–450).

Key Results and Discussion


The optimized method achieved baseline separation of all 17 phenols within a 30-minute run. Chromatograms showed sharp, well-resolved peaks spanning simple phenols to chlorinated and nitro-substituted derivatives. Retention time reproducibility was high, with RSDs below 1.5%, confirming method precision.

Benefits and Practical Applications


  • Comprehensive profiling: allows simultaneous analysis of diverse phenolic structures.
  • High sensitivity and specificity: MS detection ensures accurate identification in complex matrices.
  • Robust performance: consistent retention times and resolution support QA/QC, environmental surveillance, and industrial process monitoring.

Future Trends and Opportunities


  • Use of selective ion monitoring (SIM) or tandem MS for enhanced trace-level sensitivity.
  • Adoption of fast-GC and multidimensional techniques to reduce analysis time and increase throughput.
  • Development of portable GC–MS systems for on-site environmental and field testing.
  • Application of advanced data analytics, including chemometrics and machine learning, for peak deconvolution and automated quantification.

Conclusion


The GC–MS method using a BPX35 column provides efficient, reproducible separation and detection of a complex phenolic mixture. Its reliability and versatility make it suitable for environmental analysis, industrial QA/QC, and research laboratories.

Reference


  1. Trajan Scientific Australia Pty Ltd. Application Note AN-0070-G, December 2016.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Analysis of chlorinated and nitroaromatic compounds
Analysis of chlorinated and nitroaromatic compounds
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of chlorinated and nitroaromatic compounds BPX35 Column part number 054701 Phase BPX35 Carrier gas flow 1.8 mL/min Column 30 m x 0.25 mm x 0.25 µm Constant flow On Sample 10 ppm in methanol Average linear velocity…
Key words
nitroaromatic, nitroaromaticinjection, injectiontemperature, temperaturepentachlorophenol, pentachlorophenolcarrier, carrierhexachlorobenzene, hexachlorobenzenechlorinated, chlorinatedvelocity, velocitysim, simgas, gasliner, linerflow, flowconstant, constantfinal, finalcolumn
Analysis of a phenols mixture
Analysis of a phenols mixture
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of a phenols mixture BPX5 Column part number 054101 Phase BPX5 Carrier gas flow 2.1 mL/min Column 30 m x 0.25 mm x 0.25 µm Constant flow On Sample 200 ppm in methanol Average linear velocity 35…
Key words
injection, injectiontemperature, temperaturecarrier, carrierphenols, phenolsvelocity, velocitysim, simgas, gasliner, linerflow, flowconstant, constantfinal, finalcolumn, columnmixture, mixtureinitial, initialaverage
Analysis of chlorinated and nitroaromatic compounds
Analysis of chlorinated and nitroaromatic compounds
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of chlorinated and nitroaromatic compounds SolGel-1msTM Column part number 054795 Phase SolGel-1msTM Carrier gas flow 1.8 mL/min Column 30 m x 0.25 mm x 0.25 µm Constant flow On Sample 200 ppm in dichloromethane Average linear velocity…
Key words
nitroaromatic, nitroaromaticinjection, injectiontemperature, temperaturepentachlorophenol, pentachlorophenolcarrier, carrierhexachlorobenzene, hexachlorobenzenechlorinated, chlorinatedvelocity, velocitysim, simgas, gasliner, linerflow, flowconstant, constantfinal, finalcolumn
Analysis of USEPA 8270 mix
Analysis of USEPA 8270 mix
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of USEPA 8270 mix BPX5 Column part number 054101 Phase BPX5 Carrier gas flow 1.1 mL/min Column 30 m x 0.25 mm x 0.25 μm Constant flow On Sample 5 ppm solution Injection mode Splitless Initial temperature…
Key words
phthalate, phthalatefluoranthene, fluoranthenebenzo, benzoanthracene, anthracenepyrene, pyrenebutyl, butylpressure, pressurediethylphthalate, diethylphthalatepurge, purgefinal, finalnitrosodiphenylamine, nitrosodiphenylaminecarbazole, carbazoleinjection, injectiontemperature, temperatureazobenzene
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike