Analysis of a phenols mixture

Applications | 2016 | Trajan ScientificInstrumentation
GC/MSD, GC columns, Consumables
Industries
Manufacturer
Trajan Scientific

Summary

Significance of the topic


Phenolic compounds are widespread pollutants and valuable industrial intermediates. Their structural diversity, including chlorinated, methylated and nitro-substituted derivatives, poses analytical challenges. Reliable profiling of phenol mixtures supports environmental monitoring, quality control in chemical manufacturing and compliance with regulatory standards.

Objectives and Study Overview


This application note presents a gas chromatography–mass spectrometry (GC-MS) method for simultaneous separation and identification of eighteen phenolic analytes. The focus is on achieving rapid analysis, clear peak resolution and reproducible detection across a broad range of substituents at a concentration of 200 ppm in methanol.

Methodology and Instrumentation


The procedure employs a BPX5 capillary column (30 m×0.25 mm ID, 0.25 μm film thickness) with helium as carrier gas under constant flow (2.1 mL/min). The oven temperature program begins at 80 °C (1 min hold), ramps at 10 °C/min to 300 °C, and holds for 5 min. Samples (1 μL) are injected in split mode (100:1) via a single taper liner at 250 °C. Mass spectrometric detection is conducted in full‐scan mode over m/z 45–450, providing comprehensive spectral information for all target phenols.

Instrumentation Used


  • GC column: BPX5, 054101, 30 m×0.25 mm×0.25 μm
  • Carrier gas: Helium, 36.2 psi, constant flow 2.1 mL/min
  • Injection: Split 100:1, 1 μL, inlet temperature 250 °C, 4 mm ID single taper liner
  • Temperature program: 80 °C (1 min) → 10 °C/min → 300 °C (5 min)
  • Detector: Mass spectrometer, full scan m/z 45–450

Main Results and Discussion


The method achieved baseline separation for all eighteen phenolic compounds, including phenol, chlorophenols, cresols, xylenols and nitrophenols. Retention times were sufficiently spaced to avoid coelution, and peak shapes were symmetrical with consistent signal-to-noise ratios. Full-scan spectra enabled unambiguous identification based on molecular ions and characteristic fragment ions.

Advantages and Practical Applications


  • High resolution and selectivity for a diverse phenol mixture.
  • Fast analysis time under 30 minutes per run.
  • Robust quantitation at 200 ppm with split injection.
  • Applicability to environmental water testing, industrial process monitoring and quality assurance in chemical production.

Future Trends and Potential Applications


Integration with high-resolution accurate-mass spectrometry could enhance identification of unknown phenolic contaminants. Automation of sample preparation, including solid-phase microextraction, will further streamline workflows. Green extraction solvents and rapid chromatography techniques may reduce analysis time and environmental impact.

Conclusion


A BPX5 GC-MS method was successfully developed for comprehensive analysis of a complex phenol mixture. The approach offers reliable separation, clear mass spectral data and practicality for routine laboratory applications.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Analysis of USEPA 8270 mix
Analysis of USEPA 8270 mix
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of USEPA 8270 mix BPX5 Column part number 054101 Phase BPX5 Carrier gas flow 1.1 mL/min Column 30 m x 0.25 mm x 0.25 μm Constant flow On Sample 5 ppm solution Injection mode Splitless Initial temperature…
Key words
phthalate, phthalatefluoranthene, fluoranthenebenzo, benzopyrene, pyreneanthracene, anthracenebutyl, butylpressure, pressurediethylphthalate, diethylphthalatepurge, purgefinal, finalnitrosodiphenylamine, nitrosodiphenylaminecarbazole, carbazoleazobenzene, azobenzenebenzidine, benzidineinjection
Analysis of chlorinated and nitroaromatic compounds
Analysis of chlorinated and nitroaromatic compounds
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of chlorinated and nitroaromatic compounds SolGel-1msTM Column part number 054795 Phase SolGel-1msTM Carrier gas flow 1.8 mL/min Column 30 m x 0.25 mm x 0.25 µm Constant flow On Sample 200 ppm in dichloromethane Average linear velocity…
Key words
nitroaromatic, nitroaromaticinjection, injectiontemperature, temperaturecarrier, carrierpentachlorophenol, pentachlorophenolhexachlorobenzene, hexachlorobenzenechlorinated, chlorinatedvelocity, velocitysim, simgas, gasliner, linerflow, flowconstant, constantfinal, finalcolumn
Analysis of a phenols mixture
Analysis of a phenols mixture
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of a phenols mixture BPX35 Column part number 054701 Phase BPX35 Carrier gas flow 1.7 mL/min Column 30 m x 0.25 mm x 0.25 µm Constant flow On Sample 200 ppm in methanol Average linear velocity 35…
Key words
injection, injectiontemperature, temperaturecarrier, carrierphenols, phenolsvelocity, velocitysim, simgas, gasliner, linerflow, flowconstant, constantfinal, finalcolumn, columnmixture, mixtureinitial, initialaverage
Analysis of USEPA 8270 mix
Analysis of USEPA 8270 mix
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of USEPA 8270 mix SolGel-1msTM Column part number 054795 Phase SolGel-1msTM Carrier gas flow 1.1 mL/min Column 30 m x 0.25 mm x 0.25 μm Constant flow On Sample 10 ppm in methanol Injection mode Splitless Initial…
Key words
phthalate, phthalatefluoranthene, fluoranthenebenzo, benzopyrene, pyreneanthracene, anthracenebutyl, butylpressure, pressurediethylphthalate, diethylphthalatepurge, purgefinal, finalnitrosodiphenylamine, nitrosodiphenylaminecarbazole, carbazoleazobenzene, azobenzenebenzidine, benzidineinjection
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike