Summary

Significance of the Topic


Phthalic acid esters are widely used as plasticizers and their residues can pose health risks. Reliable analysis is crucial for compliance with food and environmental regulations and for quality control in industrial processes.

Objectives and Study Overview


This study demonstrates the application of GB/T 21911 2008 standard for the quantitation of 16 phthalate esters by GC MS using an inert capillary column. It aims to achieve baseline separation within a 22.5 minute run and ensure method robustness.

Methodology and Instrumentation


The sample is prepared at 1 microgram per milliliter in hexane and injected in splitless mode. The chromatographic system uses an InertCap 5MS/Sil column (30 meter length, 0.25 millimeter inner diameter, 0.25 micrometer film thickness) with helium carrier gas at 36.5 centimeter per second. Temperature program starts at 60 Celsius with a one minute hold, ramps at 20 Celsius per minute to 220 Celsius, then 5 Celsius per minute to 280 Celsius with a four minute final hold. Detection is performed by mass spectrometry scanning from 35 to 500 mass to charge ratio.

Used Instrumentation


  • Gas chromatograph coupled to quadrupole mass spectrometer
  • InertCap 5MS/Sil capillary column
  • Helium carrier gas
  • Splitless injector and MS transfer line at 280 Celsius

Main Results and Discussion


The method achieved baseline resolution of all 16 phthalate esters within a 22.5 minute run. The inert column surface minimized adsorption and peak tailing, enhancing sensitivity and reproducibility. Retention times increased with alkyl chain length and substitutions.

Benefits and Practical Applications


  • Compliance with national and international regulations for phthalate analysis in food packaging and environmental samples
  • High throughput with short run times
  • Robustness suitable for routine QC and research laboratories
  • Broad applicability to various sample matrices

Future Trends and Opportunities


Further improvements may include coupling to high resolution mass analyzers for confirmatory analysis, development of greener sample preparation techniques, automation of sample handling and expansion to other plasticizer classes.

Conclusion


The described GC MS method provides a rapid, sensitive and reliable tool for the analysis of 16 phthalic acid esters. The inert column chemistry and optimized temperature program ensure reproducibility and regulatory compliance.

Reference


GB/T 21911 2008 standard Data No GA178 0644 GL Sciences Inc.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Phthalic acid esters by the GB/T 21911-2008
InertSearch for GC TM InertCap® Applications Phthalic acid esters by the GB/T 21911-2008 Data No. GA179-0644 6.0 (x100,000) 5.5 5.0 2 3 4.5 4.0 1 4 3.5 8 3.0 2.5 5 2 0 2.0 6 13 9 10 7 15…
Key words
hth, hthphthalate, phthalatephth, phthhold, holdinertcap, inertcaphexyl, hexyliddi, iddiジブチ, ジブチdib, diblli, llinonyl, nonyldioctyl, dioctyldiisobutyl, diisobutylpentyl, pentyldibutyl
Phthalic acid esters
Phthalic acid esters
|GL Sciences|Applications
InertSearch for GC TM InertCap® Applications Gas Chromatography Chromatogram Phthalic acid ester atmosphere クロマトグラム フタル酸エステル 大気 GL Sciences Inc. Inc Cas. Cas No. No GC Plasticizer ジーエルサイエンス株式会社 イナートサーチ イナートキャップ 可塑剤 GC GA177 InertCap 5MS/Sil D Dimethyl phthalate Dimethyl phthalate (DMP)…
Key words
phthalate, phthalateフタル, フタルphthalic, phthalicester, esteracid, aciddioctyl, dioctylbutyl, butylheptyl, heptyldiallyl, diallyldicyclohexyl, dicyclohexyldiisobutyl, diisobutyldiheptyl, diheptylオクチル, オクチルdiisopropyl, diisopropyldiphenyl
Phthalic acid esters
Phthalic acid esters
|GL Sciences|Applications
InertSearch for GC TM InertCap® Applications Phthalic acid esters Data No. GA146-0875 (x1,000,000) 4.5 TIC 3 4.0 4 3.5 2 1 3.0 2.5 2.0 5 1.5 6 1.0 0.5 0.0 5.0 7.5 10.0 12.5 15.0 17.5 20.0 (x1,000,000) 6.0 149.00…
Key words
フタル, フタルphthalate, phthalatephthalic, phthalicoctyl, octylester, esterdidp, didpacid, acidbutyl, butylinertsearch, inertsearchinertcap, inertcapジイソデシル, ジイソデシルジイソノニル, ジイソノニルジイソノニルフタラート, ジイソノニルフタラートビニル, ビニルホルモン
Identification and Quantification of 19 Phthalic Acid Esters in Chinese Liquors Using GC-MS/MS
PO-CON1339E Identification and Quantification of 19 Phthalic Acid Esters in Chinese Liquors Using GC-MS/MS ASMS 2013 TP-748 Jiangtao Xing, Peng Gao, Furong Wang, Jun Fan, Shin-ichi Kawano Shimadzu Global COE, Shimadzu (China) Co., Ltd., China Identification and Quantification of 19…
Key words
phthalic, phthalicester, esteracid, acidliquors, liquorschinese, chinesebranched, branchedisomers, isomerspaes, paeschain, chaindiallyl, diallyldipentyl, dipentyldihexyl, dihexyldiisodecyl, diisodecyldipropyl, dipropyldiisononyl
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike