Phthalic acid esters
Applications | | GL SciencesInstrumentation
Phthalic acid esters are ubiquitous plasticizers used in a variety of consumer products and industrial materials. Due to their potential as endocrine disruptors and presence in indoor environments and food packaging, reliable methods for their detection and quantitation are critical for health and regulatory monitoring.
This application note describes the evaluation of an InertCap 1MS capillary column in gas chromatography coupled to mass spectrometry (GC/MS) for the analysis of six key phthalic acid esters. The goal is to achieve effective separation, sensitive detection and accurate quantification of di-n-butyl phthalate, benzyl butyl phthalate, di(2-ethylhexyl) phthalate, di-n-octyl phthalate, diisononyl phthalate and diisodecyl phthalate.
Sample solutions of phthalate esters at 1000 micrograms per milliliter in hexane were introduced by split injection (1 microliter). The GC oven was programmed from 50 °C to 300 °C at 20 °C per minute. Mass spectrometric detection was performed in full scan mode from 45 to 500 m/z. Quantification relied on characteristic fragments and retention times under the selected conditions.
The InertCap 1MS column achieved baseline separation for all six phthalate esters with sharp peak shapes, reflecting the inert surface chemistry. Key diagnostic ions include m/z 149 for di-n-butyl phthalate, 279 for diisononyl phthalate, 293 for di(2-ethylhexyl) phthalate and 307 for diisodecyl phthalate. Retention times increased with alkyl chain length, demonstrating predictable chromatographic behavior. The method showed consistent reproducibility and potential for low microgram level quantification.
Advances in inert column technology and high resolution mass spectrometry will further improve trace-level detection of phthalates. Emerging ambient ionization techniques and hyphenated methods such as comprehensive two-dimensional GC and supercritical fluid chromatography coupled to MS offer enhanced separation of complex isomeric mixtures. Regulatory shifts towards alternative plasticizers and tighter limits will drive demand for more sensitive and rapid screening tools.
The InertCap 1MS GC/MS method provides reliable, reproducible separation and quantification of major phthalic acid esters. Its robust peak performance and sensitivity make it well suited for environmental, industrial and regulatory applications.
GC/MSD, GC columns, Consumables
IndustriesManufacturerGL Sciences
Summary
Importance of the Topic
Phthalic acid esters are ubiquitous plasticizers used in a variety of consumer products and industrial materials. Due to their potential as endocrine disruptors and presence in indoor environments and food packaging, reliable methods for their detection and quantitation are critical for health and regulatory monitoring.
Study Objectives and Overview
This application note describes the evaluation of an InertCap 1MS capillary column in gas chromatography coupled to mass spectrometry (GC/MS) for the analysis of six key phthalic acid esters. The goal is to achieve effective separation, sensitive detection and accurate quantification of di-n-butyl phthalate, benzyl butyl phthalate, di(2-ethylhexyl) phthalate, di-n-octyl phthalate, diisononyl phthalate and diisodecyl phthalate.
Methodology
Sample solutions of phthalate esters at 1000 micrograms per milliliter in hexane were introduced by split injection (1 microliter). The GC oven was programmed from 50 °C to 300 °C at 20 °C per minute. Mass spectrometric detection was performed in full scan mode from 45 to 500 m/z. Quantification relied on characteristic fragments and retention times under the selected conditions.
Instrumentation
- Gas chromatograph coupled to a quadrupole mass spectrometer
- InertCap 1MS capillary column, 0.25 mm internal diameter, 15 m length, 0.10 μm film thickness
- Oven temperature program: initial 50 °C, ramp 20 °C/min to 300 °C
- Carrier gas: helium at 60 cm/s
- Injection: split mode, 54.3 mL/min split flow
- MS detection: scan range 45–500 m/z, interface temperature 300 °C
Main Results and Discussion
The InertCap 1MS column achieved baseline separation for all six phthalate esters with sharp peak shapes, reflecting the inert surface chemistry. Key diagnostic ions include m/z 149 for di-n-butyl phthalate, 279 for diisononyl phthalate, 293 for di(2-ethylhexyl) phthalate and 307 for diisodecyl phthalate. Retention times increased with alkyl chain length, demonstrating predictable chromatographic behavior. The method showed consistent reproducibility and potential for low microgram level quantification.
Benefits and Practical Applications
- Environmental monitoring of semivolatile organic compounds in air and water
- Quality control of plasticizers in polymer manufacturing
- Regulatory compliance testing for toys and food contact materials
- Assessment of consumer exposure to endocrine disruptors
Future Trends and Possibilities
Advances in inert column technology and high resolution mass spectrometry will further improve trace-level detection of phthalates. Emerging ambient ionization techniques and hyphenated methods such as comprehensive two-dimensional GC and supercritical fluid chromatography coupled to MS offer enhanced separation of complex isomeric mixtures. Regulatory shifts towards alternative plasticizers and tighter limits will drive demand for more sensitive and rapid screening tools.
Conclusion
The InertCap 1MS GC/MS method provides reliable, reproducible separation and quantification of major phthalic acid esters. Its robust peak performance and sensitivity make it well suited for environmental, industrial and regulatory applications.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Phthalic acid esters
|GL Sciences|Applications
InertSearch for GC TM InertCap® Applications Gas Chromatography Chromatogram Phthalic acid ester atmosphere クロマトグラム フタル酸エステル 大気 GL Sciences Inc. Inc Cas. Cas No. No GC Plasticizer ジーエルサイエンス株式会社 イナートサーチ イナートキャップ 可塑剤 GC GA177 InertCap 5MS/Sil D Dimethyl phthalate Dimethyl phthalate (DMP)…
Key words
phthalate, phthalateフタル, フタルphthalic, phthalicester, esteracid, aciddioctyl, dioctylbutyl, butyldiallyl, diallylheptyl, heptyldicyclohexyl, dicyclohexyldiisobutyl, diisobutylオクチル, オクチルdiheptyl, diheptyldiisopropyl, diisopropyldiphenyl
Phthalic acid esters by the GB/T 21911-2008
|GL Sciences|Applications
InertSearch for GC TM InertCap® Applications Phthalic acid esters by the GB/T 21911-2008 Data No. GA178-0644 6.0 (x100,000) 5.5 5.0 2 4.5 3 4 0 4.0 3.5 1 4 3.0 7 8 5 2.5 2.0 9 10 6 13 11…
Key words
phthalate, phthalatehth, hthdep, depinertcap, inertcapジシクロヘキシル, ジシクロヘキシルジシクロヘキシルフタレ, ジシクロヘキシルフタレdith, dithフタルサンジエチル, フタルサンジエチルphth, phthフタル, フタルhold, holdmin, minnonyl, nonylphthalic, phthalicdiisobutyl
Phthalic acid esters by the GB/T 21911-2008
|GL Sciences|Applications
InertSearch for GC TM InertCap® Applications Phthalic acid esters by the GB/T 21911-2008 Data No. GA179-0644 6.0 (x100,000) 5.5 5.0 2 3 4.5 4.0 1 4 3.5 8 3.0 2.5 5 2 0 2.0 6 13 9 10 7 15…
Key words
hth, hthphthalate, phthalatephth, phthhold, holdinertcap, inertcaphexyl, hexyliddi, iddiジブチ, ジブチdib, diblli, llinonyl, nonyldioctyl, dioctyldiisobutyl, diisobutylpentyl, pentyldibutyl
Analysis of Phthalate Esters in Children's Toys Using GC-MS
2011|Shimadzu|Applications
C146-E152 Analysis of Phthalate Esters in Children's Toys Using GC-MS GC/MS Technical Report No.4 Yuki Sakamoto, Katsuhiro Nakagawa, Haruhiko Miyagawa Abstract As of February 2009, the US Consumer Product Safety Improvement Act, Section 108, mandated that all manufacturers of children’s…
Key words
phthalate, phthalatesim, simscan, scandnop, dnopdidp, didpdinp, dinpbbp, bbpdbp, dbpistd, istddehp, dehpfasst, fassttoys, toysmeasurements, measurementsdiethylhexyl, diethylhexylterephthalic