Monitoring volatile organic compounds (VOCs) in water is critical for environmental safety, regulatory compliance and public health. Trace-level detection of chlorinated and aromatic hydrocarbons ensures early identification of contamination events and supports decision-making in water quality management.
This application note demonstrates the use of EPA Method 524 implemented on the CDS 7000 Purge & Trap system coupled to a GC/MS platform. The objective is to achieve reliable, high-resolution analysis of 61 priority VOCs at a 20 ppb concentration in drinking water matrices within a 20-minute run time.
The procedure follows EPA Method 524 steps:
The combined system produced a complete chromatogram in under 20 minutes, resolving the first six gaseous compounds (e.g., dichlorodifluoromethane, chloromethane, vinyl chloride) with sharp peaks and minimal tailing. Overall, all 61 EPA Method 524 target analytes ranging up to naphthalene were detected reliably at the 20 ppb level. The water elimination trap effectively prevented moisture interference, and the bake-out step maintained trap performance over successive runs.
This approach offers:
Emerging developments may include advanced sorbent materials for broader VOC coverage, automated sampler integration for 24/7 monitoring, miniaturized purge & trap modules for field deployment, and integration with artificial intelligence algorithms for real-time data interpretation.
The CDS 7000 Purge & Trap system coupled with GC/MS reliably implements EPA Method 524 for rapid, sensitive detection of VOCs in water. It delivers reproducible results, streamlined workflow and supports regulatory compliance efforts.
GC/MSD, Purge and Trap, GC/SQ
IndustriesEnvironmental
ManufacturerAgilent Technologies, CDS Analytical
Summary
Significance of the Topic
Monitoring volatile organic compounds (VOCs) in water is critical for environmental safety, regulatory compliance and public health. Trace-level detection of chlorinated and aromatic hydrocarbons ensures early identification of contamination events and supports decision-making in water quality management.
Aims and Study Overview
This application note demonstrates the use of EPA Method 524 implemented on the CDS 7000 Purge & Trap system coupled to a GC/MS platform. The objective is to achieve reliable, high-resolution analysis of 61 priority VOCs at a 20 ppb concentration in drinking water matrices within a 20-minute run time.
Methodology and Instrumentation Used
The procedure follows EPA Method 524 steps:
- Sample Purge: 10 mL of water purged with helium at 40 mL/min for 11 minutes.
- Water Elimination: Upstream trap removes moisture before analyte collection.
- Sorbent Trap: Multi-bed sorbent collects VOCs, followed by desorb-preheat at 245 °C.
- Thermal Desorption: Trap heated to 250 °C for 2 minutes, then baked at 260 °C for 10 minutes to prepare for the next sample.
- GC/MS Conditions: Agilent 6890 GC with 5975B MS, Varian CP 624 CB column (30 m×0.25 mm, 1.4 µm film). Carrier flow 1.3 mL/min, split 40:1. Temperature program: 40 °C hold 5 min, ramp 10 °C/min to 180 °C.
Major Results and Discussion
The combined system produced a complete chromatogram in under 20 minutes, resolving the first six gaseous compounds (e.g., dichlorodifluoromethane, chloromethane, vinyl chloride) with sharp peaks and minimal tailing. Overall, all 61 EPA Method 524 target analytes ranging up to naphthalene were detected reliably at the 20 ppb level. The water elimination trap effectively prevented moisture interference, and the bake-out step maintained trap performance over successive runs.
Benefits and Practical Applications of the Method
This approach offers:
- High throughput analysis suitable for routine monitoring and compliance testing.
- Low detection limits appropriate for regulatory thresholds.
- Robust trap design minimizing carryover and downtime.
- Compatibility with existing GC/MS infrastructure in environmental and QA/QC laboratories.
Future Trends and Potential Applications
Emerging developments may include advanced sorbent materials for broader VOC coverage, automated sampler integration for 24/7 monitoring, miniaturized purge & trap modules for field deployment, and integration with artificial intelligence algorithms for real-time data interpretation.
Conclusion
The CDS 7000 Purge & Trap system coupled with GC/MS reliably implements EPA Method 524 for rapid, sensitive detection of VOCs in water. It delivers reproducible results, streamlined workflow and supports regulatory compliance efforts.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
EPA Metthod 524 Ussiing tthe CDS 7000 Purrge & Trrap
|Agilent Technologies|Applications
JSB is an authorised partner of #116 EPA Method 524 Using the CDS 7000 Purge & Trap The analysis of water for volatile organic contaminants using purge and trap…
Key words
jsb, jsbwet, wettrap, trapchloroporpane, chloroporpaneeindhoven, eindhovenzoex, zoexauthorised, authorisedupstream, upstreamorganic, organicheadquarters, headquartersireland, irelandpurged, purgedpartner, partnersales, salesbelgium
CDS 7000C PAL System Purge and Trap Plugin
2016|CDS Analytical|Brochures and specifications
Leaders In GC Sample Introduction Technology CDS 7000C PAL System Purge and Trap Plugin • The Industries First Purge and Trap Concentrator for PAL Autosamplers 465 Limestone Road, Oxford, PA 19363-0277, USA Tel: 800-541-6593 Fax: 610-932-4158 www.cdsanalytical.com CDS A Introduction…
Key words
trap, trapbenzene, benzeneplugin, pluginpurge, purgexylene, xylenesparge, spargeheated, heatedinternal, internalpal, palzoom, zoommodule, modulereference, referencevessle, vesslesilconert, silconertsorbant
Purge and Trap Sample Introduction Instruments
2017|CDS Analytical|Brochures and specifications
Leaders In GC Sample Introduction Technology • Purge and Trap Sample Introduction Instruments Reliable Purge and Trap Concentrator with 2nd Generation Autosampler Options for both Water and Soil Samples 465 Limestone Road, Oxford, PA 19363-0277, USA Tel: 800-541-6593 Fax: 610-932-4158…
Key words
programmable, programmabletrap, trapbenzene, benzeneautosampler, autosamplersoil, soilpathway, pathwaypurge, purgesample, samplepanel, panelxylene, xylenefoam, foamrinses, rinsescds, cdsaliquots, aliquotszoom
Optimizing the Analysis of Volatile Organic Compounds
2003|Restek|Guides
Technical Guide 1 Optimizing the Analysis of Volatile Organic Compounds Inside: EPA Method Definitions State GRO Methods Contract Laboratory Program (CLP) The Love Canal Scandal Purge and Trap Theory Sequences and Flow Paths of the Purge and Trap Unit Purge…
Key words
pack, packxylene, xylenertx, rtxtert, tertpid, pidpurge, purgebutylbenzene, butylbenzeneelcd, elcdeach, eachchloride, chloridetrap, trapbenzene, benzenedata, dataacetate, acetatevgc