Optimizing the performance of your Shimadzu gc with agilent columns & Supplies
Brochures and specifications | 2015 | Agilent TechnologiesInstrumentation
High-performance gas chromatography (GC) is essential for accurate trace-level analysis in environmental testing, food safety, forensic investigations, and industrial QA/QC. Optimized flow path inertness, low-bleed columns, and reliable sample preparation directly impact sensitivity, reproducibility, and instrument uptime. Ensuring peak GC performance reduces false negatives, lowers maintenance, and extends column and detector life.
This work evaluates how Agilent GC supplies—inlet liners, flow-path components, J&W capillary columns, gas filters, and sample prep consumables—enhance the performance of Shimadzu GC and GC/MS systems. Comparative studies demonstrate improvements in signal response, bleed profiles, and chromatographic stability when replacing OEM parts with Agilent equivalents.
Comparative experiments were conducted on a Shimadzu QP-2010 GC/MS platform using:
Retention profiles, total ion chromatograms, signal-to-noise ratios, and bleed levels were measured under equivalent temperature and carrier-gas conditions.
Replacing Shimadzu OEM liners and ferrules with Agilent Ultra Inert components yielded:
Agilent J&W Ultra Inert columns matched selectivity of standard phases while providing consistent inertness for active compounds, verified by rigorous multi-probe testing that includes acidic, basic, and polar test molecules.
The growing demand for ultra-trace analysis will drive further innovations in ultra-inert surface chemistries and high-efficiency column formats (sub-0.18 mm ID, thinner films). Integration of smart diagnostics and remote monitoring will enable predictive maintenance. Expanding QuEChERS and SPE workflows to novel food matrices and emerging contaminants will continue to streamline sample preparation. Adoption of multi-dimensional GC and GC×GC with optimized Agilent supply chains offers next-generation resolution and sensitivity.
Adopting Agilent GC supplies on Shimadzu instruments substantially improves chromatographic performance, sensitivity, and operational efficiency. Upgrading to Ultra Inert liners, Self-Tightening nuts, advanced columns, gas filters, and validated sample-prep consumables delivers clear benefits for routine and trace analyses, while reducing downtime and total cost of ownership.
Agilent Publication 5991-5522EN: “Optimizing the performance of your Shimadzu GC with Agilent GC supplies”
Sample Preparation, GC columns, Consumables
IndustriesManufacturerAgilent Technologies, Shimadzu
Summary
Significance of the Topic
High-performance gas chromatography (GC) is essential for accurate trace-level analysis in environmental testing, food safety, forensic investigations, and industrial QA/QC. Optimized flow path inertness, low-bleed columns, and reliable sample preparation directly impact sensitivity, reproducibility, and instrument uptime. Ensuring peak GC performance reduces false negatives, lowers maintenance, and extends column and detector life.
Objectives and Overview
This work evaluates how Agilent GC supplies—inlet liners, flow-path components, J&W capillary columns, gas filters, and sample prep consumables—enhance the performance of Shimadzu GC and GC/MS systems. Comparative studies demonstrate improvements in signal response, bleed profiles, and chromatographic stability when replacing OEM parts with Agilent equivalents.
Methodology and Instrumentation Used
Comparative experiments were conducted on a Shimadzu QP-2010 GC/MS platform using:
- Standard OEM flow-path components versus Agilent Ultra Inert liners, Self-Tightening column nuts, Ultra Inert ferrules, and deactivated fused-silica tubing
- Agilent J&W low-bleed columns such as DB-UI 8270D, DB-5, DB-1, DB-35ms, and specialty phases (DB-EUPAH for PAHs, CP-Sil PONA CB for hydrocarbons)
- Agilent GC gas Clean filters (oxygen, moisture, organics, CO₂ removal)
- Agilent Bond Elut SPE and QuEChERS kits for sample cleanup
Retention profiles, total ion chromatograms, signal-to-noise ratios, and bleed levels were measured under equivalent temperature and carrier-gas conditions.
Main Results and Discussion
Replacing Shimadzu OEM liners and ferrules with Agilent Ultra Inert components yielded:
- Up to 30–50% higher signal response for semivolatiles and pesticides, enabling lower detection limits and more reliable integration
- Significantly reduced column bleed at elevated temperatures, improving late-eluting analyte quantitation and extending column life
- Stable leak-free seals over >150 thermal cycles with Self-Tightening column nuts, minimizing retightening and associated downtime
- Cleaner carrier gas via gas Clean filters, protecting columns and detectors from contamination
Agilent J&W Ultra Inert columns matched selectivity of standard phases while providing consistent inertness for active compounds, verified by rigorous multi-probe testing that includes acidic, basic, and polar test molecules.
Benefits and Practical Uses of the Method
- Enhanced sensitivity and reproducibility at trace-level concentrations for environmental semivolatiles, PAHs, pesticides, food contaminants, and forensic analytes
- Extended column and detector lifetime, reducing consumable costs and maintenance frequency
- Streamlined workflow by consolidating GC supplies and service support under a single vendor
- Compatibility with existing Shimadzu hardware without method revalidation, thanks to identical selectivity profiles
Future Trends and Opportunities for Use
The growing demand for ultra-trace analysis will drive further innovations in ultra-inert surface chemistries and high-efficiency column formats (sub-0.18 mm ID, thinner films). Integration of smart diagnostics and remote monitoring will enable predictive maintenance. Expanding QuEChERS and SPE workflows to novel food matrices and emerging contaminants will continue to streamline sample preparation. Adoption of multi-dimensional GC and GC×GC with optimized Agilent supply chains offers next-generation resolution and sensitivity.
Conclusion
Adopting Agilent GC supplies on Shimadzu instruments substantially improves chromatographic performance, sensitivity, and operational efficiency. Upgrading to Ultra Inert liners, Self-Tightening nuts, advanced columns, gas filters, and validated sample-prep consumables delivers clear benefits for routine and trace analyses, while reducing downtime and total cost of ownership.
Reference
Agilent Publication 5991-5522EN: “Optimizing the performance of your Shimadzu GC with Agilent GC supplies”
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
GC AND GC/MS - Your Essential Resource for Columns & Supplies
2016|Agilent Technologies|Brochures and specifications
Buy online: www.agilent.com/chem/store Contact us: www.agilent.com/chem/contactus THE ESSENTIAL CHROMATOGRAPHY & SPECTROSCOPY CATALOG For more information This information is subject to change without notice. © Agilent Technologies, Inc. 2014 Printed in Canada October XX, 2014 5991-5213EN GC AND GC/MS Your Essential…
Key words
agilent, agilentsupplies, suppliescolumns, columnslength, lengthparts, partscrosslab, crosslabcolumn, columnfilm, filmsuggested, suggesteddescription, descriptionrinsable, rinsableoem, oemultimetal, ultimetaltips, tipsnut
Agilent GENERAL CHROMATOGRAPHY catalog
2012|Agilent Technologies|Others
Buy online: www.agilent.com/chem/store Contact us: www.agilent.com/chem/contactus This information is subject to change without notice. © Agilent Technologies, Inc. 2012 Printed in Canada October 31, 2012 5991-1056EN Scan the QR code with your smartphone for more information THE ESSENTIAL CHROMATOGRAPHY &…
Key words
ptfe, ptfesilicone, siliconesepta, septacrosslab, crosslabvials, vialsneedle, needleagilent, agilentreplacement, replacementdescription, descriptionplunger, plungerclosures, closuressyringes, syringesunit, unitfixed, fixedclear
Agilent GC AND GC/MS - Catalog Consumables and Spare Parts
2016|Agilent Technologies|Others
Buy online: www.agilent.com/chem/store Contact us: www.agilent.com/chem/contactus THE ESSENTIAL CHROMATOGRAPHY & SPECTROSCOPY CATALOG For more information This information is subject to change without notice. © Agilent Technologies, Inc. 2016 Printed in Canada March 8, 2016 5991-5213EN GC AND GC/MS Your Essential…
Key words
supplies, suppliesagilent, agilentparts, partscrosslab, crosslabdescription, descriptionoem, oemnut, nutinlet, inletliners, linerssepta, septaferrule, ferrulecolumn, columnneedle, needlestick, stickassembly
Agilent GC AND GC/MS Columns Catalog
2016|Agilent Technologies|Others
Buy online: www.agilent.com/chem/store Contact us: www.agilent.com/chem/contactus THE ESSENTIAL CHROMATOGRAPHY & SPECTROSCOPY CATALOG For more information This information is subject to change without notice. © Agilent Technologies, Inc. 2016 Printed in Canada March 8, 2016 5991-5213EN GC AND GC/MS Your Essential…
Key words
agilent, agilentcolumns, columnslength, lengthfilm, filmrinsable, rinsableultimetal, ultimetalltm, ltmcolumn, columnitalicized, italicizedbonded, bondedchromosorb, chromosorbtest, testdescriptions, descriptionsmesh, meshlinked