Agilent Intuvo 9000 GC System Columns and Supplies
Brochures and specifications | 2019 | Agilent TechnologiesInstrumentation
Gas chromatography (GC) is a vital analytical tool for trace-level separations in environmental, forensic, food, and petrochemical laboratories. Advances in GC instrumentation directly improve throughput, data quality, and operational costs. The Agilent Intuvo 9000 GC System represents a significant innovation by integrating fast direct heating, intuitive hardware interfaces, and a suite of dedicated columns and consumables designed to simplify workflows and reduce downtime.
This document presents key design features, consumable products, and performance advantages of the Agilent Intuvo 9000 GC System. It reviews the system’s architecture, specialized columns and supplies, and supporting accessories, aiming to inform analysts and lab managers about how Intuvo re-imagines GC operations for enhanced productivity and reliability.
The Intuvo 9000 GC System employs solid-state direct oven heating and rapid cooling to achieve up to 2× faster analyses while consuming only 25% of the power of conventional GC. The system automatically monitors over 100 internal touchpoints, displaying real-time instrument health on a built-in touchscreen. Key instrumentation and accessories include:
Intuvo’s planar column design and smart connections eliminate column trimming and ferrule assembly errors. Guard Chips extend column life by filtering out matrix residues without retention time shifts. Click-and-run fittings provide audible feedback and consistent installation torque. The system’s built-in diagnostics reduce troubleshooting time, while direct heating ensures uniform temperature profiles and rapid cycle times.
Laboratories benefit from:
Upcoming developments may include deeper integration with laboratory information management systems (LIMS), AI-driven predictive maintenance algorithms, expanded custom column offerings via online configurators, and broader support for advanced detectors (e.g., infrared, vacuum ultraviolet). The modular architecture positions Intuvo for rapid adaptation to emerging applications, such as biofuel analysis and microplastic detection.
The Agilent Intuvo 9000 GC System transforms traditional gas chromatography by combining rapid direct heating, intuitive consumables, and embedded diagnostics. It offers a cost-effective premium solution that simplifies operation, extends column life, and enhances data reliability across a wide range of applications.
GC
IndustriesManufacturerAgilent Technologies
Summary
Significance of the Topic
Gas chromatography (GC) is a vital analytical tool for trace-level separations in environmental, forensic, food, and petrochemical laboratories. Advances in GC instrumentation directly improve throughput, data quality, and operational costs. The Agilent Intuvo 9000 GC System represents a significant innovation by integrating fast direct heating, intuitive hardware interfaces, and a suite of dedicated columns and consumables designed to simplify workflows and reduce downtime.
Objectives and Overview of the Document
This document presents key design features, consumable products, and performance advantages of the Agilent Intuvo 9000 GC System. It reviews the system’s architecture, specialized columns and supplies, and supporting accessories, aiming to inform analysts and lab managers about how Intuvo re-imagines GC operations for enhanced productivity and reliability.
Methodology and Used Instrumentation
The Intuvo 9000 GC System employs solid-state direct oven heating and rapid cooling to achieve up to 2× faster analyses while consuming only 25% of the power of conventional GC. The system automatically monitors over 100 internal touchpoints, displaying real-time instrument health on a built-in touchscreen. Key instrumentation and accessories include:
- Agilent Intuvo 9000 GC with integrated touchscreen and EPC modules
- Intuvo Guard Chips and Jumper Chips for ferrule-free, no-trim column protection
- Intuvo Flow Chips supporting split/splitless, backflush, dual detectors, and MS configurations
- Smart ID-enabled Intuvo columns coated with Ultra Inert, low-bleed, polysiloxane, WAX/PEG, high-temperature, and specialty phases
- Detector tails and ferrule-free gaskets for leak-free face seals
- Ultra Inert inlet liners with touchless preconditioned packaging
- Agilent Blue Line autosampler syringes, nonstick BTO septa, Gas Clean filters, ADM Flow Meter, and installation kits
Main Results and Discussion
Intuvo’s planar column design and smart connections eliminate column trimming and ferrule assembly errors. Guard Chips extend column life by filtering out matrix residues without retention time shifts. Click-and-run fittings provide audible feedback and consistent installation torque. The system’s built-in diagnostics reduce troubleshooting time, while direct heating ensures uniform temperature profiles and rapid cycle times.
Benefits and Practical Applications
Laboratories benefit from:
- Reduced training requirements and simplified method transfers
- Higher throughput with faster ramp rates and minimal cooldown times
- Lower operating costs due to reduced power consumption and fewer consumable replacements
- Enhanced data quality via Ultra Inert columns and low-bleed components
- Streamlined maintenance through automated health checks and modular replaceable chips
Future Trends and Opportunities
Upcoming developments may include deeper integration with laboratory information management systems (LIMS), AI-driven predictive maintenance algorithms, expanded custom column offerings via online configurators, and broader support for advanced detectors (e.g., infrared, vacuum ultraviolet). The modular architecture positions Intuvo for rapid adaptation to emerging applications, such as biofuel analysis and microplastic detection.
Conclusion
The Agilent Intuvo 9000 GC System transforms traditional gas chromatography by combining rapid direct heating, intuitive consumables, and embedded diagnostics. It offers a cost-effective premium solution that simplifies operation, extends column life, and enhances data reliability across a wide range of applications.
Reference
- Agilent Technologies. Agilent Intuvo 9000 GC System Catalog and Consumables Guide. Publication 5991-9325EN (2019).
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent Inert Flow Path Solutions - Quick Reference Guide
2021|Agilent Technologies|Guides
Quick Reference Guide Agilent Inert Flow Path Solutions Agilent’s 7890B, 8890, and 8860 Inert Flow Path Split/Splitless Inlet option ensures the inertness of flow path surfaces, allowing analytes to safely pass from injector to detector. For best trace level analysis,…
Key words
intuvo, intuvoinert, inertfilm, filmlength, lengthtemp, tempultra, ultralimits, limitsferrule, ferruleultimetal, ultimetalgold, goldagilent, agilentflexible, flexiblemetal, metalwool, woolpath
Detect Every Peak and Minimize Degradative Buildup in Your GC Flow Path - Agilent Inert Flow Path solutions
2020|Agilent Technologies|Brochures and specifications
Detect Every Peak and Minimize Degradative Buildup in Your GC Flow Path Agilent Inert Flow Path solutions Ensuring an Inert Flow Path from Injection Through Detection Is Critical—and Now, Easy to Achieve As regulatory agencies drive limits of detection lower…
Key words
inert, inertagilent, agilentultra, ultrapath, pathliners, linersultimetal, ultimetalplus, plusflow, flowinlet, inletinertness, inertnessdeactivation, deactivationyour, yourmetal, metalflexible, flexiblegold
8890 Gas Chromatography (GC) System with 7693A Automatic Liquid Sampler (Essential Instrument Supplies)
2025|Agilent Technologies|Others
Essential Instrument Supplies Agilent technical experts have compiled a list of recommended supplies that you should consider using with your new instrument in order to keep your lab operational without any disruptions and to achieve optimal performance. 8890 Gas Chromatography…
Key words
recommendation, recommendationintuvo, intuvotop, tophydroinert, hydroinertferrules, ferrulescolumn, columnspecific, specificinlet, inletrecommended, recommendedrough, roughmsds, msdsmanagement, managementliners, linerssepta, septabto
Optimizing the performance of your Shimadzu gc with agilent columns & Supplies
2015|Agilent Technologies|Brochures and specifications
Optimizing the perfOrmance Of yOur Shimadzu gc with agilent cOlumnS & SupplieS Agilent gC SupplieS for ShimAdzu table of contents introduction...........................................................................3 improve the performance of your Shimadzu Qp2010 with agilent gc Supplies..................4 inert flow path components .............................................5 Ultra Inert Inlet…
Key words
ptfe, ptfeshimadzu, shimadzuagilent, agilentsilicone, siliconepolypropylene, polypropyleneunit, unitsepta, septacolumns, columnslength, lengthfilm, filmdescription, descriptiontemp, tempitalicized, italicizedclosures, closuresinert