GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

GC AND GC/MS - Your Essential Resource for Columns & Supplies

Brochures and specifications | 2016 | Agilent TechnologiesInstrumentation
GC columns, Consumables
Industries
Manufacturer
Agilent Technologies

Summary

Essential Gas Chromatography and GC/MS Supplies for Reliable Trace-Level Analysis



Význam tématu


Gas chromatography (GC) and GC coupled to mass spectrometry (GC/MS) remain foundational analytical techniques across environmental, food, pharmaceutical and forensic laboratories. Achieving low detection limits, robust quantitation and consistent retention times demands not only high-performance instruments but also rigorously controlled columns, inlet liners, seals and accessories. Advances in inert flow paths and low-bleed consumables directly impact sensitivity, reproducibility and instrument uptime, especially for active or labile analytes at trace levels.

Cíle a přehled katalogu


This catalog presents Agilent’s comprehensive portfolio of GC and GC/MS systems, columns and supplies, including Ultra Inert deactivated liners and columns, Bulk GC supplies, CrossLab compatibility products, autosampler components, headspace and purge-and-trap consumables, and thermal desorption tubes. The objective is to help users minimize downtime, maintain system inertness, maximize sensitivity and simplify routine maintenance.

Použitá instrumentace


  • Agilent GC systems: 7890B, 7820A, 6850 Series II
  • Agilent GC/MS detectors: 5977 Series, 5975T LTM, 7000C/7010 triple quadrupole, 7200 Q-TOF
  • Autosamplers: 7693A ALS, 7697A and 7693 Headspace Samplers
  • Purge-and-trap: Stratum PTC and Atomx Concentrators
  • Thermal Desorption: Markes UNITY and standard TD tubes
  • Columns: Agilent J&W Ultra Inert GC columns, mass spec grade columns, LTM modules

Metodika a klíčové vlastnosti


The catalog details consumable design and selection criteria:
  • Ultra Inert deactivation chemistry for inlet liners and columns to reduce active analyte adsorption and bleed
  • Precision liner dimensions, dedicated glass wool placement and exclusive Touchless packaging with pre-cleaned O-rings for consistent installation
  • Graphite/polyimide, polyimide and UltiMetal Plus ferrule options for robust, leak-free capillary connections including Self-Tightening column nuts
  • Premium non-stick septa (BTO, Advanced Green, Long-Life) tested up to 400 °C
  • Agilent CrossLab supplies for non-Agilent instruments, backed by a 90-day compatibility warranty
  • Headspace consumables: crimp and screw caps, high-performance septa rated to 300 °C
  • Purge-and-trap traps and spargers for environmental VOC/SVOC sampling
  • Markes TD tubes and cold traps for a wide analyte range (C2–C40, sulfur, greenhouse gases)

Hlavní výsledky a diskuse


Performance testing demonstrates:
  • Ultra Inert liners with glass wool maintain analyte recovery and reproducibility across hundreds of injections, reducing endrin breakdown compared to standard liners
  • Touchless packaging speeds liner replacement and eliminates contamination from manual O-ring handling
  • Self-Tightening nuts maintain column seals through thermal cycling, reducing re-tightening and leaks
  • High-temperature headspace septa yield minimal bleed and background at 300 °C, improving trace VOC analysis

Přínosy a praktické využití metody


Implementing these consumables in routine GC and GC/MS workflows leads to:
  • Lower detection limits and improved data quality for active compounds in environmental, food safety, pharmaceutical and forensic testing
  • Reduced instrument downtime through longer-life liners, ferrules and septa
  • Easier maintenance and faster column changes using standardized, preconditioned parts
  • Expanded compatibility to non-Agilent systems via CrossLab supplies
  • Streamlined headspace, purge-and-trap and thermal desorption setups for volatile and semivolatile analysis

Budoucí trendy a možnosti využití


Future directions in GC/GC-MS consumables and accessories include:
  • Further inert flow path innovations to support ever-lower detection limits and labile compound analysis
  • Integration of smart packaging and RFID tracking for real-time inventory management and traceability
  • Growing adoption of multi-dimensional GC and rapid-cycle systems requiring tailored consumables
  • Expansion of CrossLab compatibility offerings as laboratories diversify their instrument portfolios
  • Advances in automated sample introduction and data-driven maintenance scheduling

Závěr


High-quality consumables are as critical as the instrument itself to achieve reliable, trace-level GC and GC/MS results. Agilent’s extensive catalog offers rigorously tested, user-friendly solutions—from Ultra Inert liners and columns to automated headspace septa and CrossLab supplies—to optimize performance, reproducibility and lab efficiency.

Reference


None

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Optimizing the performance of your Shimadzu gc with agilent columns & Supplies
Optimizing the performance of your Shimadzu gc with agilent columns & Supplies
2015|Agilent Technologies|Brochures and specifications
Optimizing the perfOrmance Of yOur Shimadzu gc with agilent cOlumnS & SupplieS Agilent gC SupplieS for ShimAdzu table of contents introduction...........................................................................3 improve the performance of your Shimadzu Qp2010 with agilent gc Supplies..................4 inert flow path components .............................................5 Ultra Inert Inlet…
Key words
ptfe, ptfeshimadzu, shimadzuagilent, agilentsilicone, siliconepolypropylene, polypropyleneunit, unitsepta, septacolumns, columnslength, lengthfilm, filmdescription, descriptiontemp, tempitalicized, italicizedclosures, closuresinert
Agilent GC AND GC/MS Columns Catalog
Agilent GC AND GC/MS Columns Catalog
2016|Agilent Technologies|Others
Buy online: www.agilent.com/chem/store Contact us: www.agilent.com/chem/contactus THE ESSENTIAL CHROMATOGRAPHY & SPECTROSCOPY CATALOG For more information This information is subject to change without notice. © Agilent Technologies, Inc. 2016 Printed in Canada March 8, 2016 5991-5213EN GC AND GC/MS Your Essential…
Key words
agilent, agilentcolumns, columnslength, lengthfilm, filmrinsable, rinsableultimetal, ultimetalltm, ltmcolumn, columnitalicized, italicizedbonded, bondedchromosorb, chromosorbtest, testdescriptions, descriptionsmesh, meshlinked
Detect Every Peak and Minimize Degradative Buildup in Your GC Flow Path - Agilent Inert Flow Path solutions
Detect Every Peak and Minimize Degradative Buildup in Your GC Flow Path Agilent Inert Flow Path solutions Ensuring an Inert Flow Path from Injection Through Detection Is Critical—and Now, Easy to Achieve As regulatory agencies drive limits of detection lower…
Key words
inert, inertagilent, agilentultra, ultrapath, pathliners, linersultimetal, ultimetalplus, plusflow, flowinlet, inletinertness, inertnessdeactivation, deactivationyour, yourmetal, metalflexible, flexiblegold
Agilent GC AND GC/MS - Catalog Consumables and Spare Parts
Buy online: www.agilent.com/chem/store Contact us: www.agilent.com/chem/contactus THE ESSENTIAL CHROMATOGRAPHY & SPECTROSCOPY CATALOG For more information This information is subject to change without notice. © Agilent Technologies, Inc. 2016 Printed in Canada March 8, 2016 5991-5213EN GC AND GC/MS Your Essential…
Key words
supplies, suppliesagilent, agilentparts, partscrosslab, crosslabdescription, descriptionoem, oemnut, nutinlet, inletliners, linerssepta, septaferrule, ferrulecolumn, columnneedle, needlestick, stickassembly
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike