Teledyne Tekmar Atomx XYZ – Site Preparation Checklist

Manuals | 2017 | Agilent TechnologiesInstrumentation
Purge and Trap
Industries
Manufacturer
Teledyne LABS

Summary

Importance of the Topic


Ensuring proper laboratory setup for gas sampling accessories such as the G8160A Teledyne Tekmar Atomx XYZ is critical to maintain analytical accuracy, operator safety, and long-term instrument reliability in environmental and industrial applications.

Objectives and Overview


This checklist aims to guide laboratory managers through space planning, environmental conditioning, power allocation, and required consumables to streamline installation and commissioning of the Atomx XYZ sampling accessory. It summarizes site specifications and customer responsibilities to facilitate timely deployment.

Methodology and Instrumentation


  • The document provides a structured approach to site assessment before delivery and installation.
  • It covers key parameters: bench dimensions, environmental conditions, electrical supply, and consumable inventory.
  • Instrumentation:
    • G8160A Teledyne Tekmar Atomx XYZ gas sampling accessory


Main Results and Discussion


The site requirements defined include:
  • Bench footprint of 58.4 cm depth, 49.5 cm width, and clearance of at least 70.1 cm height to accommodate a weight of 43.1 kg.
  • Stable ambient temperature between 10 °C and 30 °C, relative humidity up to 90%, and avoidance of direct heat sources or drafts to ensure performance.
  • Dedicated power circuits providing 100–120 V or 220–240 V at 50/60 Hz, supporting a maximum consumption of 1150 W (1200 VA).
  • Preparation of operating supplies such as carrier gases, solvents, and waste containment based on vendor recommendations.
These specifications minimize installation delays and support safe operation.

Benefits and Practical Applications


  • Streamlined installation reduces downtime and labor costs.
  • Compliance with environmental and power requirements enhances data quality in air monitoring, emission testing, and analytical research.
  • Proper consumable planning avoids workflow interruptions during routine sampling campaigns.


Future Trends and Possibilities for Application


Anticipated developments include:
  • Integration of IoT-enabled sensors for real-time monitoring of environmental conditions around the instrument.
  • Automated site validation tools to confirm compliance prior to installation.
  • Expansion of modular bench designs to support multi-instrument configurations with shared utilities.


Conclusion


Adhering to the outlined site preparation checklist ensures that the Teledyne Tekmar Atomx XYZ accessory operates at peak performance from day one. A thorough preinstallation assessment contributes to reliable data generation and extends equipment service life.

References


  • Agilent Technologies. G8160A Teledyne Tekmar Atomx XYZ Site Preparation Checklist. Issued November 2017.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Teledyne Tekmar ATOMX Purge and Trap - Site Preparation Checklist
Teledyne Tekmar ATOMX Purge and Trap Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation…
Key words
atomx, atomxpurge, purgemultimatrix, multimatrixteledyne, teledynetekmar, tekmartrap, trapchecklist, checklistsite, sitecustomer, customeroperating, operatingspecial, specialconcentrator, concentratortechnologies, technologiesdescription, descriptionnotes
Teledyne Tekmar Aquatek LVA – Site Preparation Checklist
  G8161A - Teledyne Tekmar Aquatek LVA – Site Preparation Checklist Thank you for purchasing a Tekmar Aquatek LVA. To get you started and to assure a successful and timely installation, please refer to this specification or set of…
Key words
checklist, checklistsite, sitecustomer, customerrevision, revisiontechnologies, technologieslva, lvaaquatek, aquatekspecial, specialagilent, agilentpreparation, preparationparagraph, paragraphoperating, operatingresponsibilities, responsibilitiesnotes, notessection
Teledyne Tekmar Aquatek100 Purge and Trap - Site Preparation Checklist
Teledyne Tekmar Aquatek100 Purge and Trap Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation…
Key words
checklist, checklistsite, sitecustomer, customeroperating, operatingspecial, specialtechnologies, technologiesdescription, descriptionnotes, notesconsumption, consumptioninstrument, instrumentpreparation, preparationagilent, agilentweight, weightpower, powersupplies
Teledyne Tekmar Lumin Purge and Trap - Site Preparation Checklist
Teledyne Tekmar Lumin Purge and Trap Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation…
Key words
lumin, luminpurge, purgetrap, traptekmar, tekmarteledyne, teledynechecklist, checklistsite, siteconcentrator, concentratortechnologies, technologiescustomer, customeroperating, operatingspecial, specialagilent, agilentinstrument, instrumentpreparation
Other projects
LCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike