Author
LECO
LECO
In 1936, the Laboratory Equipment Company introduced the first rapid carbon determinator for the American iron and steel industry. Today, almost 80 years later, LECO is recognized globally as a leader in the development of high-quality analytical instrumentation, mass spectrometers, comprehensive two-dimensional chromatography, metallography & optical equipment as well as consumables.
Tags
Article
Product
LinkedIn Logo

As Helium Prices Rise and Supply Shrinks, LECO Customers Have Reliable Alternatives

Th, 16.4.2026
| Original article from: LECO
Helium shortages are disrupting labs worldwide. Discover how LECO instruments enable reliable analysis using alternative carrier gases like hydrogen, nitrogen, and argon.
<p><strong>LECO:&nbsp;</strong>As Helium Prices Rise and Supply Shrinks, LECO Customers Have Reliable Alternatives</p>

LECO: As Helium Prices Rise and Supply Shrinks, LECO Customers Have Reliable Alternatives

Labs that rely on helium gas are facing a major crisis…unless they have LECO instruments. Due to the military conflict in the Middle East, Qatar’s Ras Laffan Industrial City, the world’s largest helium production hub, providing one-third of the world’s helium, has shut down operations. To make matters worse, the Strait of Hormuz, the shipping lane used to export helium, has also been closed, meaning even pre-filled helium containers are stuck with no viable route to customers. Naturally, the price of helium has now risen dramatically; most spot prices have doubled. A critical scarcity issue is looming as the world must now operate on roughly 5.2 million cubic meters per month less of helium. 

Why Helium Cost and Supply Matters to Labs 

Although many people may recognize helium as the gas that fills party balloons, it plays a critical role in much more serious matters. Helium has unique properties, like an extremely low boiling point, inertness, and high thermal conductivity, which makes it indispensable in several high-tech applications.  

For example, research labs may use helium as a carrier gas when performing elemental analyses or gas chromatography-mass spectrometry, which is used to separate and identify chemical compounds in samples. But research labs are often government-funded and run under strict budgets, so the price hike on helium could mean labs have to pause their research until everything falls back under control, which could be months or longer. Even well-funded labs could suffer if the supply is simply too stretched to equip the lab with what they need, as medical uses are given top priority. This could have a serious impact on accuracy and compliance with regulated methods.  

The Consequences Reach Farther 

When helium becomes unavailable or prohibitively expensive, the ripple effects are immediate and far-reaching. It affects more than just balloons and research labs: 

  • Delayed Medical Diagnostics: MRI machines, which rely on helium to cool their superconducting magnets, may be taken offline, delaying critical scans. 
  • Semiconductor Bottlenecks: Chip shortages could worsen, impacting everything from smartphones to electric vehicles and AI infrastructure. 
  • Industrial Disruption: Welding, aerospace, and fiber optics manufacturing face rising costs and potential production halts. 

LECO’s Solution: Instruments That Don’t Rely on Helium  

Amidst this pending crisis, LECO offers a practical and forward-thinking solution. This marks the 5th major helium supply crisis since 2006, and it’s likely there will be more after this. Helium supply is concentrated to just a few regions, meaning that any time there is a disruption to one of these, it can create a large effect on the industry. That’s why we designed our innovative analytical instruments to operate using alternative carrier gases.  

Depending on the instrument, alternative gases such as nitrogen, argon, or hydrogen may be used in place of helium. These gases are abundant, cost-effective, and less prone to the geopolitical volatility that plagues helium supply chains.  

LECO’s helium-free options ensure that operations stay online, efficient, and future-proof in a world where helium is becoming increasingly scarce and expensive. This flexibility is no longer a luxury—it’s a necessity. If your lab or facility is feeling the pressure of helium scarcity, now is the time to explore alternatives. This isn’t the first helium shortage, and it won’t be the last. Is your lab prepared?

LECO Instruments Supporting Non-Helium Carrier Gases 

Pegasus BT (Bench-Top GC–TOFMS, incl. BT 4D)

LECO: Pegasus BTLECO: Pegasus BT

Pegasus BTX (Next-gen BT, incl. BTX 4D)

LECO: Pegasus BTXLECO: Pegasus BTX

Pegasus HRT (High-Resolution TOF-MS, incl. 4D)

  • Supported Carrier Gases: Helium or Hydrogen
  • Notes on Usage / Limitations: High-resolution GC–TOFMS systems support H₂ as a carrier gas as well as He. Note: Strict safety protocols apply due to hydrogen’s flammability. Hydrogen use is not recommended in instruments/configurations where gas could accumulate (e.g. very long, vertical flight tubes), but LECO’s HRT instruments utilize Folded Flight Path technology, which eliminates this concern. 
  • App Note: “GC–MS Analysis with Hydrogen Carrier Gas on GC×GC-HRTOFMS (MMS Ion Source)”

LECO: Pegasus HRTLECO: Pegasus HRT

LECO 828 Series (Nitrogen/Protein/Carbon/Hydrogen)

  • Supported Carrier Gases: Helium or Argon 
  • Notes on Usage / Limitations: The LECO 828 Series supports argon as an alternative carrier gas to helium. Helium provides higher TCD sensitivity (important for low-N samples), whereas argon operation raises the nitrogen detection limit and slightly reduces low-range precision. Switching gas type simply requires updating the method and flow settings (no hardware change required).
  • App Note: “Carbon, Hydrogen, and Nitrogen in Biomass using CHN828” 

LECO 828 SeriesLECO 828 Series

LECO 928 Series (Nitrogen/Protein/Carbon/Sulfur)

  • Supported Carrier Gases: Helium or Argon 
  • Notes on Usage / Limitations: The LECO 928 Series also supports argon carrier gas as an alternative to helium. Helium use gives the best sensitivity and lowest detection limits for nitrogen, while argon use increases analysis time slightly and raises the nitrogen detection limit (due to the smaller thermal conductivity difference). The 928-series instruments have built-in settings for either gas; when switching, users adjust flow and select the appropriate carrier gas in the system settings. Users also have the option to select a larger aliquot loop in the analysis method to improve precision. 
  • App Note: “Determination of Carbon and Nitrogen in Carbon Black and Graphite”

LECO 928 SeriesLECO 928 Series

736/836 Series (Inert Gas Fusion O2/N2 /H2  analyzers)

  • Supported Carrier Gases: Helium or Argon 
  • Notes on Usage / Limitations: LECO’s inert gas fusion analyzers for oxygen and nitrogen in inorganic materials (e.g. models ON736, ON836) traditionally use helium as the carrier for the TCD measuring N2. These systems can run on argon as well, provided the appropriate He/Ar dual-purpose TCD is installed. Switching from He to Ar in these instruments is a one-time setup change; both gases are supported in the software (selectable “Gas Type” setting). When using argon, the furnace runs hotter and produces more soot, so maintenance (filter changes, cleaning) becomes more frequent. Low-level nitrogen precision is also slightly lessened with argon.  
  • App Note: “Determination of Oxygen, Nitrogen, and Hydrogen in Iron, Steel, Nickel-base, and Cobalt-base Alloys: Comparison of Analytical Performance Between Argon and Helium Carrier” 

LECO 736 SeriesLECO 736 Series

LECO 836 SeriesLECO 836 Series

DH603 Hydrogen Determinator

  • Supported Carrier Gases: Nitrogen (carrier), Helium (calibration gas) 
  • Notes on Usage / Limitations: The DH603 measures diffusible and residual hydrogen in metals by hot extraction. It does not use helium as a carrier during analysis—instead it uses nitrogen as the purge/carrier gas in the TCD system. A small helium dose is used only for calibration and system checks (to introduce a known H2 quantity via He-H2 mix). In routine operation, the furnace is purged with N2 and any hydrogen released from the sample is carried to a TCD that references against the nitrogen background. This design avoids flammable gas in the instrument entirely. 
  • App Note: “Hydrogen Determination in Steel Samples Using DH603” 

LECO: DH603 Hydrogen DeterminatorLECO: DH603 Hydrogen Determinator

LECO
LinkedIn Logo
 

Related content

Alcohol Determination of Sanitizer Gel Using Nexis GC-2060

Applications
| 2026 | Shimadzu
Instrumentation
GC
Manufacturer
Shimadzu
Industries
Pharma & Biopharma

Sensitive and Reproducible Determination of Nitrosamines by GC/MSD

Applications
| 2026 | Agilent Technologies
Instrumentation
GC/MSD, GC/SQ
Manufacturer
Agilent Technologies
Industries
Environmental

High-Throughput BTEX Analysis in Nail Products by SPME and GC/TQ

Applications
| 2026 | Agilent Technologies
Instrumentation
GC/MSD, GC/MS/MS, GC/QQQ, SPME
Manufacturer
Agilent Technologies
Industries
Materials Testing

Accurate multi-component blast furnace gas analysis maximizes iron production and minimizes coke consumption

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
GC/MSD
Manufacturer
Thermo Fisher Scientific
Industries
Energy & Chemicals

Gas Chromatograph Nexis GC-2060

Brochures and specifications
| 2026 | Shimadzu
Instrumentation
GC
Manufacturer
Shimadzu
Industries
Other
 

Related articles

GC & GC/MS Helium to Hydrogen Conversion Quick Reference Guide
Article | Science and research

GC & GC/MS Helium to Hydrogen Conversion Quick Reference Guide

This quick reference guide is set out to provide information on using and converting a instrument or a whole laboratory from helium to hydrogen.
ChromSolutions
tag
share
more
News from LabRulezGCMS Library - Week 31, 2024
Article | Application

News from LabRulezGCMS Library - Week 31, 2024

New applications and other documents by LECO, Agilent Technologies, Metrohm and Shimadzu in LabRulez Library.
LabRulez
tag
share
more
News from LabRulezGCMS Library - Week 48, 2025
Article | Application

News from LabRulezGCMS Library - Week 48, 2025

This week we bring you brochure by Agilent Technologies, poster by LECO /MDCW, and application notes by Shimadzu and Thermo Fisher Scientific!
LabRulez
tag
share
more
News from LabRulezGCMS Library - Week 04, 2026
Article | Application

News from LabRulezGCMS Library - Week 04, 2026

This week we bring you application notes by Agilent Technologies, BaySpec and Metrohm!
LabRulez
tag
share
more
 

Related content

Alcohol Determination of Sanitizer Gel Using Nexis GC-2060

Applications
| 2026 | Shimadzu
Instrumentation
GC
Manufacturer
Shimadzu
Industries
Pharma & Biopharma

Sensitive and Reproducible Determination of Nitrosamines by GC/MSD

Applications
| 2026 | Agilent Technologies
Instrumentation
GC/MSD, GC/SQ
Manufacturer
Agilent Technologies
Industries
Environmental

High-Throughput BTEX Analysis in Nail Products by SPME and GC/TQ

Applications
| 2026 | Agilent Technologies
Instrumentation
GC/MSD, GC/MS/MS, GC/QQQ, SPME
Manufacturer
Agilent Technologies
Industries
Materials Testing

Accurate multi-component blast furnace gas analysis maximizes iron production and minimizes coke consumption

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
GC/MSD
Manufacturer
Thermo Fisher Scientific
Industries
Energy & Chemicals

Gas Chromatograph Nexis GC-2060

Brochures and specifications
| 2026 | Shimadzu
Instrumentation
GC
Manufacturer
Shimadzu
Industries
Other
 

Related articles

GC & GC/MS Helium to Hydrogen Conversion Quick Reference Guide
Article | Science and research

GC & GC/MS Helium to Hydrogen Conversion Quick Reference Guide

This quick reference guide is set out to provide information on using and converting a instrument or a whole laboratory from helium to hydrogen.
ChromSolutions
tag
share
more
News from LabRulezGCMS Library - Week 31, 2024
Article | Application

News from LabRulezGCMS Library - Week 31, 2024

New applications and other documents by LECO, Agilent Technologies, Metrohm and Shimadzu in LabRulez Library.
LabRulez
tag
share
more
News from LabRulezGCMS Library - Week 48, 2025
Article | Application

News from LabRulezGCMS Library - Week 48, 2025

This week we bring you brochure by Agilent Technologies, poster by LECO /MDCW, and application notes by Shimadzu and Thermo Fisher Scientific!
LabRulez
tag
share
more
News from LabRulezGCMS Library - Week 04, 2026
Article | Application

News from LabRulezGCMS Library - Week 04, 2026

This week we bring you application notes by Agilent Technologies, BaySpec and Metrohm!
LabRulez
tag
share
more
 

Related content

Alcohol Determination of Sanitizer Gel Using Nexis GC-2060

Applications
| 2026 | Shimadzu
Instrumentation
GC
Manufacturer
Shimadzu
Industries
Pharma & Biopharma

Sensitive and Reproducible Determination of Nitrosamines by GC/MSD

Applications
| 2026 | Agilent Technologies
Instrumentation
GC/MSD, GC/SQ
Manufacturer
Agilent Technologies
Industries
Environmental

High-Throughput BTEX Analysis in Nail Products by SPME and GC/TQ

Applications
| 2026 | Agilent Technologies
Instrumentation
GC/MSD, GC/MS/MS, GC/QQQ, SPME
Manufacturer
Agilent Technologies
Industries
Materials Testing

Accurate multi-component blast furnace gas analysis maximizes iron production and minimizes coke consumption

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
GC/MSD
Manufacturer
Thermo Fisher Scientific
Industries
Energy & Chemicals

Gas Chromatograph Nexis GC-2060

Brochures and specifications
| 2026 | Shimadzu
Instrumentation
GC
Manufacturer
Shimadzu
Industries
Other
 

Related articles

GC & GC/MS Helium to Hydrogen Conversion Quick Reference Guide
Article | Science and research

GC & GC/MS Helium to Hydrogen Conversion Quick Reference Guide

This quick reference guide is set out to provide information on using and converting a instrument or a whole laboratory from helium to hydrogen.
ChromSolutions
tag
share
more
News from LabRulezGCMS Library - Week 31, 2024
Article | Application

News from LabRulezGCMS Library - Week 31, 2024

New applications and other documents by LECO, Agilent Technologies, Metrohm and Shimadzu in LabRulez Library.
LabRulez
tag
share
more
News from LabRulezGCMS Library - Week 48, 2025
Article | Application

News from LabRulezGCMS Library - Week 48, 2025

This week we bring you brochure by Agilent Technologies, poster by LECO /MDCW, and application notes by Shimadzu and Thermo Fisher Scientific!
LabRulez
tag
share
more
News from LabRulezGCMS Library - Week 04, 2026
Article | Application

News from LabRulezGCMS Library - Week 04, 2026

This week we bring you application notes by Agilent Technologies, BaySpec and Metrohm!
LabRulez
tag
share
more
 

Related content

Alcohol Determination of Sanitizer Gel Using Nexis GC-2060

Applications
| 2026 | Shimadzu
Instrumentation
GC
Manufacturer
Shimadzu
Industries
Pharma & Biopharma

Sensitive and Reproducible Determination of Nitrosamines by GC/MSD

Applications
| 2026 | Agilent Technologies
Instrumentation
GC/MSD, GC/SQ
Manufacturer
Agilent Technologies
Industries
Environmental

High-Throughput BTEX Analysis in Nail Products by SPME and GC/TQ

Applications
| 2026 | Agilent Technologies
Instrumentation
GC/MSD, GC/MS/MS, GC/QQQ, SPME
Manufacturer
Agilent Technologies
Industries
Materials Testing

Accurate multi-component blast furnace gas analysis maximizes iron production and minimizes coke consumption

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
GC/MSD
Manufacturer
Thermo Fisher Scientific
Industries
Energy & Chemicals

Gas Chromatograph Nexis GC-2060

Brochures and specifications
| 2026 | Shimadzu
Instrumentation
GC
Manufacturer
Shimadzu
Industries
Other
 

Related articles

GC & GC/MS Helium to Hydrogen Conversion Quick Reference Guide
Article | Science and research

GC & GC/MS Helium to Hydrogen Conversion Quick Reference Guide

This quick reference guide is set out to provide information on using and converting a instrument or a whole laboratory from helium to hydrogen.
ChromSolutions
tag
share
more
News from LabRulezGCMS Library - Week 31, 2024
Article | Application

News from LabRulezGCMS Library - Week 31, 2024

New applications and other documents by LECO, Agilent Technologies, Metrohm and Shimadzu in LabRulez Library.
LabRulez
tag
share
more
News from LabRulezGCMS Library - Week 48, 2025
Article | Application

News from LabRulezGCMS Library - Week 48, 2025

This week we bring you brochure by Agilent Technologies, poster by LECO /MDCW, and application notes by Shimadzu and Thermo Fisher Scientific!
LabRulez
tag
share
more
News from LabRulezGCMS Library - Week 04, 2026
Article | Application

News from LabRulezGCMS Library - Week 04, 2026

This week we bring you application notes by Agilent Technologies, BaySpec and Metrohm!
LabRulez
tag
share
more
Other projects
LCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike