GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Solid Phase Microextraction/Capillary GC: Rapid, Sensitive Detection of Gasoline in Fire Debris

Applications | 1998 | MerckInstrumentation
GC, SPME, Consumables
Industries
Forensics , Homeland Security
Manufacturer
Merck

Summary

Significance of the Topic


The rapid and reliable detection of gasoline residues in fire debris is essential in forensic investigations of arson. Traditional sampling methods are often time-consuming, require toxic organic solvents, and can incur losses during sample handling. Headspace solid phase microextraction (SPME) combined with capillary gas chromatography (GC) provides a solvent-free, efficient alternative that enhances sensitivity, reduces analysis time, and minimizes operator exposure to hazardous chemicals.

Objectives and Study Overview


This study aimed to develop and validate a simple, cost-effective, and highly sensitive headspace SPME/GC method for the analysis of gasoline in fire debris. The goals were to compare its performance against conventional passive headspace concentration, to determine detection limits, and to evaluate applicability to minute gasoline volumes under realistic forensic conditions.

Methodology and Instrumentation


The method employed a 100 micrometer polydimethylsiloxane-coated SPME fiber for headspace sampling. Key steps included:
  • Thermal equilibration of samples (0.04–5 µL of gasoline) at 40 °C for 30 min.
  • Headspace fiber exposure for 20 min without solvent extraction.
  • Thermal desorption in the GC injector (220 °C, splitless for 3 min), followed by split 50:1.

The GC conditions were as follows:
  • Column: 30 m × 0.25 mm ID, 0.25 µm PDMS film.
  • Oven program: 35 °C (2 min), ramp to 220 °C at 10 °C/min (2 min hold), then to 300 °C at 30 °C/min (5 min hold).
  • Carrier gas: Helium at 1 mL/min.
  • Detector: Flame ionization detector at 300 °C.

Instrumentation Used


The analysis utilized a manual SPME fiber holder with a 100 µm PDMS fiber assembly. A Hamilton heated syringe cleaner was used to thermally clean the fiber between runs. The GC system was equipped with a PDMS capillary column and FID, all supplied by Supelco/Sigma-Aldrich.

Main Results and Discussion


Comparison with passive headspace concentration showed significant enhancements in detector response for key gasoline components:
  • Ethylbenzene: 1.0-fold increase.
  • n-Butylbenzene: 3.8-fold increase.
  • 2-Methylnaphthalene: 11.2-fold increase.

SPME/GC produced identifiable chromatograms from as little as 0.04 µL of gasoline, outperforming passive sampling limits of 0.1 µL. The technique eliminated sample handling losses, since the entire extracted analyte load is introduced directly into the column. Analysis time was reduced from approximately 16 hours (passive sampling) to under 20 minutes per sample, and per-sample cost was cut by more than half.

Benefits and Practical Applications


This SPME/GC approach offers multiple advantages for forensic and industrial analyses:
  • Solvent-free extraction enhances laboratory safety and reduces disposal costs.
  • Rapid headspace sampling enables high throughput screening of fire debris.
  • Improved sensitivity and low detection limits facilitate identification of trace flammable residues.
  • Minimal sample handling reduces risk of cross-contamination and analyte loss.

Future Trends and Potential Applications


Advances in fiber coatings and instrumental automation will further broaden SPME applications in forensic, environmental, and food analyses. Combining headspace and immersion sampling strategies can selectively target volatile and nonvolatile compounds as needed. Integration with mass spectrometry promises enhanced compound identification and quantification. Ongoing developments include:
  • Customized fiber phases for tailored selectivity.
  • Robotic autosampling for unattended high throughput.
  • Miniaturized GC systems for on-site forensic screening.

Conclusion


Headspace SPME coupled with capillary GC represents a rapid, sensitive, and economical solution for the detection of gasoline in fire debris. By eliminating solvents, reducing analysis time, and improving detection limits, this method enhances forensic laboratory efficiency and safety. Its adaptability to other volatile and semi-volatile analytes underscores its value across multiple analytical fields.

References


  • Furton, K. G.; Almirall, J. R.; Bruna, J. C. Journal of Forensic Sciences, in press.
  • Yang, X.; Peppard, T. Journal of Agricultural and Food Chemistry 1994, 42, 1925–1930.
  • Zhang, Z.; Pawliszyn, J. Analytical Chemistry 1993, 65, 1843–1852.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
SPME/GC for Forensic Applications: Explosives, Fire Debris, and Drugs of Abuse
Bulletin 922 SPME/GC for Forensic Applications: Explosives, Fire Debris, and Drugs of Abuse Solid phase microextraction is a fast, solventless alternative to conventional sample extraction techniques. In SPME, analytes establish equilibria among the sample matrix, the headspace above the sample,…
Key words
spme, spmefiber, fibersupelco, supelcourine, urineheadspace, headspacecocaine, cocainesampling, samplingdescription, descriptionexplosives, explosivesamphetamine, amphetaminemicroextraction, microextractionamphetamines, amphetaminesmanual, manualanalytes, analytesdebris
Solid Phase Microextraction of Semivolatile Compounds
Application Note 6 Solid Phase Microextraction of Semivolatile Compounds An SPME fiber coated with 7µm of polydimethylsiloxane is ideal for extracting semivolatile compounds from water. The SPME technology eliminates the use of solvents in extracting water samples for organic compound…
Key words
benzo, benzobutylphthalate, butylphthalatemanual, manualsampling, samplinganthracene, anthracenefluoranthene, fluoranthenespme, spmediethylphthalate, diethylphthalatedimethylphthalate, dimethylphthalatepyrene, pyrenesemivolatile, semivolatiledibenz, dibenzmicroextraction, microextractionoctylphthalate, octylphthalateghi
Solid Phase Microextraction: Theory and Optimization of Conditions
Bulletin 923 Solid Phase Microextraction: Theory and Optimization of Conditions Solid phase microextraction, a simple, effective adsorption/ desorption technique, eliminates the need for solvents or complicated apparatus for concentrating volatile or nonvolatile compounds in liquid samples or headspace. SPME is…
Key words
spme, spmefiber, fibercoating, coatingholder, holderanalyte, analytepdms, pdmsdesorption, desorptionsampling, samplingsupelco, supelcohplc, hplcdescription, descriptionextraction, extractionpolar, polarnonpolar, nonpolarcarboxen
Monitor BTEX Compounds and Fuels in Water, Using Solid Phase Microextraction and Capillary GC
Application Note 81 Monitor BTEX Compounds and Fuels in Water, Using Solid Phase Microextraction and Capillary GC BTEX compounds, kerosene, diesel fuel, or gasoline in water or aqueous suspensions of soil can be monitored by solid phase microextraction (SPME) and…
Key words
btex, btexmanual, manualsampling, samplingspme, spmesuspensions, suspensionsvarian, variangasoline, gasolinefuels, fuelssoil, soilxylene, xylenehydrocarbons, hydrocarbonsassortment, assortmentaqueous, aqueouseach, eachkerosene
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike