Agilent 7250 GC/Q-TOF - Data Sheet

Brochures and specifications | 2017 | Agilent TechnologiesInstrumentation
GC/MSD, GC/MS/MS, GC/HRMS, GC/TOF
Industries
Manufacturer
Agilent Technologies

Summary

Significance of the Topic



The Agilent 7250 GC/Q-TOF system combines gas chromatography with high-resolution quadrupole time-of-flight mass spectrometry to address the need for highly sensitive and selective analysis of complex mixtures. Its accurate mass measurements and fast spectral acquisition support confident identification of unknown compounds and deconvolution of coeluting peaks in applications spanning environmental analysis, forensics, pharmaceuticals, and metabolomics.

Objectives and Study Overview



This document summarizes the key performance features of the Agilent 7250 GC/Q-TOF coupled with the Agilent 7890B Gas Chromatograph. It focuses on demonstrating system sensitivity, mass accuracy, resolution, MS/MS capabilities, and acquisition speed to support both qualitative structure elucidation and quantitative workflows.

Methodology and Instrumentation



The analytical configuration comprises:
  • Electron Ionization modes: Conventional 70 eV and low-energy EI (5–200 eV)
  • Inert non-coated ion source (100–350 °C) with quick-vent nitrogen purge
  • Gold-coated quartz quadrupole (20–1,050 m/z) offering selectable resolution (0.4–4.0 Da)
  • Hexapole collision cell with He/N₂ (4:1) for MS/MS (up to 60 eV)
  • 3 m TOF flight path and microchannel plate detector with 160 Gbit/s ADC sampling
  • Four-stage turbomolecular pumping system and SWARM autotune
  • Agilent MassHunter software suite for acquisition, qualitative and quantitative data analysis, and reporting
  • Agilent 7890B GC featuring split/splitless and multimode inlets, versatile autosampling, electronic pneumatic control, and oven range ambient +4 °C to 450 °C

Main Results and Discussion



Highlighted performance metrics:
  • Acquisition rates up to 50 Hz to capture narrow chromatographic peaks in full scan mode
  • Instrument detection limit below 60 fg OFN (octafluoronaphthalene) at m/z 271.9867
  • Mass resolution >25 000 (FWHM) and mass accuracy better than 2 ppm RMS
  • Dynamic electronic range exceeding 10⁵ counts
The combination of rapid data acquisition, accurate mass measurement, and SureMass deconvolution software effectively resolves coeluting analytes that are inseparable by unit-resolution MS. MS/MS fragmentation further enhances selectivity and minimizes matrix interferences.

Benefits and Practical Applications


  • Ultra-trace detection capabilities for environmental and toxicological analyses
  • High-resolution accurate mass for reliable unknown identification
  • MS/MS structural elucidation to reduce false positives and confirm compound identity
  • Fast throughput compatible with narrow GC peaks and complex sample matrices
  • Advanced deconvolution improving quantitative reliability in challenging separations

Future Trends and Opportunities


  • Integration with AI-driven data processing and automated identification workflows
  • Expansion to comprehensive two-dimensional GC × GC–Q-TOF for enhanced separation power
  • Growth of accurate-mass spectral libraries for rapid compound matching
  • Emerging applications in exposomics, food authenticity verification, and new psychoactive substances screening

Conclusion



The Agilent 7250 GC/Q-TOF, paired with the 7890B GC and MassHunter software, delivers outstanding sensitivity, selectivity, and mass accuracy. Its high-resolution capabilities, rapid acquisition, and MS/MS functionality make it an indispensable platform for advanced analytical challenges across research, quality control, and regulated laboratories.

References


  • Agilent Technologies, Agilent 7250 GC/Q-TOF Data Sheet, 2017.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Agilent 7200B Series GC/Q-TOF System - Data Sheet
Agilent 7200B Series GC/Q-TOF System - Data Sheet
2014|Agilent Technologies|Brochures and specifications
Agilent 7200B Series GC/Q-TOF System Data Sheet The Agilent 7200B Series Q-TOF GC/MS System with Agilent MassHunter Software offers outstanding sensitivity, selectivity, and mass spectral information. High resolution and accurate mass allows identification of unknown compounds in the most complex…
Key words
mass, masstof, tofturbomolecular, turbomolecularpci, pcirough, roughquadrupole, quadrupolepneumatic, pneumaticion, ionsource, sourcecollision, collisioninseparable, inseparableresolution, resolutionpump, pumpfull, fullisolation
Agilent 7200 Series Q-TOF GC/MS System - Data Sheet
Agilent 7200 Series Q-TOF GC/MS System - Data Sheet
2012|Agilent Technologies|Brochures and specifications
Agilent 7200 Series Q-TOF GC/MS System Data Sheet The Agilent 7200 Series Q-TOF GC/MS System with MassHunter software offers outstanding sensitivity, selectivity, and mass spectral information. High resolution and accurate mass allows trace-level identification of unknown compounds, in addition to…
Key words
mass, masstof, tofpci, pcisource, sourcesnr, snrquadrupole, quadrupolefilaments, filamentsflow, flowpneumatic, pneumaticaccuracy, accuracyion, ionoctofluoronaphthalene, octofluoronaphthalenecollision, collisiononly, onlygoldcoated
Agilent 7000B Triple Quadrupole GC/MS System
Agilent 7000B Triple Quadrupole GC/MS System
2012|Agilent Technologies|Brochures and specifications
Agilent 7000B Triple Quadrupole GC/MS System Data Sheet Agilent is leading the way by introducing IDL, Instrument Detection Limit, as a new metric for meaningful indication of system sensitivity. In MS/MS baselines with very little noise, the dubious selection of…
Key words
mrm, mrmpci, pciidl, idlfilaments, filamentsnci, ncielectronic, electronicmodes, modespneumatic, pneumaticmore, morecollision, collisiontriple, triplesheet, sheetaxis, axisquadrupole, quadrupolecustomary
Agilent 7000B Triple Quadrupole GC/MS System - Data Sheet
Agilent 7000B Triple Quadrupole GC/MS System - Data Sheet
2011|Agilent Technologies|Brochures and specifications
Agilent 7000B Triple Quadrupole GC/MS System Data Sheet Agilent is leading the way by introducing IDL, Instrument Detection Limit, as a new metric for meaningful indication of system sensitivity. In MS/MS baselines with very little noise, the dubious selection of…
Key words
mrm, mrmpci, pcifilaments, filamentsnci, ncielectronic, electronicmodes, modesidl, idlpneumatic, pneumaticmore, moretriple, triplecollision, collisionsheet, sheetaxis, axisquadrupole, quadrupolecustomary
Other projects
LCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike