Agilent 7000B Triple Quadrupole GC/MS System
Brochures and specifications | 2012 | Agilent TechnologiesInstrumentation
Gas chromatography coupled with tandem mass spectrometry (GC-MS/MS) is a cornerstone technique in analytical chemistry for the sensitive and selective detection of trace organic compounds. The introduction of reliable metrics such as Instrument Detection Limit (IDL) provides a more accurate measure of system performance compared to traditional signal-to-noise ratios, ensuring robust quantification in environmental, food safety, and pharmaceutical applications.
The primary aim of the Agilent 7000B Triple Quadrupole GC/MS System is to deliver high sensitivity, reproducibility, and throughput in quantitative analyses. This system integrates a triple quadrupole mass spectrometer with advanced ion sources (EI, PCI, NCI) and is coupled to the Agilent 7890A gas chromatograph. Key objectives include achieving low femtogram-level detection limits, broad dynamic range, and rapid multiple reaction monitoring (MRM) capabilities.
The system operates in MS/MS mode with two proprietary gold-coated quadrupoles flanking a linear hexapole collision cell. Ionization techniques available include:
Key instrumental parameters:
The GC system (Agilent 7890A) features split/splitless and multi-mode inlets, an autosampler, and precise temperature control up to 450 °C.
Instrument Detection Limits measured at installation demonstrate exceptional sensitivity:
The system exhibits stable mass calibration (<±0.10 u over 24 h) and robust dynamic range, enabling reliable quantification across diverse sample matrices. Simultaneous acquisition of GC detector signals further enhances analytical throughput.
By combining high sensitivity with rapid MRM acquisition, the 7000B system supports:
The use of IDL ensures consistent system performance validation, critical for regulated laboratories.
Advancements may include:
The Agilent 7000B GC/MS system exemplifies modern triple quadrupole technology, offering outstanding sensitivity, precision, and flexibility for a wide range of trace analysis tasks. Its emphasis on IDL-based performance metrics and robust instrumentation makes it a valuable platform for analytical laboratories aiming for reliable quantification at femtogram levels.
GC/MSD, GC/MS/MS, GC/QQQ
IndustriesManufacturerAgilent Technologies
Summary
Importance of the topic
Gas chromatography coupled with tandem mass spectrometry (GC-MS/MS) is a cornerstone technique in analytical chemistry for the sensitive and selective detection of trace organic compounds. The introduction of reliable metrics such as Instrument Detection Limit (IDL) provides a more accurate measure of system performance compared to traditional signal-to-noise ratios, ensuring robust quantification in environmental, food safety, and pharmaceutical applications.
Objectives and overview
The primary aim of the Agilent 7000B Triple Quadrupole GC/MS System is to deliver high sensitivity, reproducibility, and throughput in quantitative analyses. This system integrates a triple quadrupole mass spectrometer with advanced ion sources (EI, PCI, NCI) and is coupled to the Agilent 7890A gas chromatograph. Key objectives include achieving low femtogram-level detection limits, broad dynamic range, and rapid multiple reaction monitoring (MRM) capabilities.
Methodology and instrumentation
The system operates in MS/MS mode with two proprietary gold-coated quadrupoles flanking a linear hexapole collision cell. Ionization techniques available include:
- Electron Ionization (EI) with a high-sensitivity extraction source
- Positive Chemical Ionization (PCI)
- Negative Chemical Ionization (NCI)
Key instrumental parameters:
- Mass range: m/z 10–1050
- Resolution: 0.7–2.5 Da (default tune), adjustable to 0.4–4.0 Da
- Dynamic range: >106
- Scan rate: up to 6250 u/s
- MRM transitions/sec: up to 500
- Ion source temperature: 106–350 °C
- Collision energy: up to 60 eV
The GC system (Agilent 7890A) features split/splitless and multi-mode inlets, an autosampler, and precise temperature control up to 450 °C.
Key results and discussion
Instrument Detection Limits measured at installation demonstrate exceptional sensitivity:
- EI MRM IDL: ≤12 fg octafluoronaphthalene (99% confidence)
- PCI MRM S/N: >2500:1 for benzophenone at 5 pg/µL
- Typical EI scan S/N: >300:1 for 1 pg/µL octafluoronaphthalene
The system exhibits stable mass calibration (<±0.10 u over 24 h) and robust dynamic range, enabling reliable quantification across diverse sample matrices. Simultaneous acquisition of GC detector signals further enhances analytical throughput.
Benefits and practical applications
By combining high sensitivity with rapid MRM acquisition, the 7000B system supports:
- Trace-level pesticide and contaminant monitoring
- Residue analysis in food and environmental samples
- Drug metabolism and forensic toxicology studies
The use of IDL ensures consistent system performance validation, critical for regulated laboratories.
Future trends and applications
Advancements may include:
- Integration with comprehensive two-dimensional GC (GC×GC) for enhanced separation
- Automated data analysis using machine learning
- Further miniaturization of ion sources for lower gas consumption
- Online coupling with sample preparation techniques for high-throughput screening
Conclusion
The Agilent 7000B GC/MS system exemplifies modern triple quadrupole technology, offering outstanding sensitivity, precision, and flexibility for a wide range of trace analysis tasks. Its emphasis on IDL-based performance metrics and robust instrumentation makes it a valuable platform for analytical laboratories aiming for reliable quantification at femtogram levels.
References
- Agilent Technologies Inc. Agilent 7000B Triple Quadrupole GC/MS System Data Sheet, 5989-9625EN, 2012.
- Agilent Technologies Inc. 7890A GC Data Sheet.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent 7000B Triple Quadrupole GC/MS System - Data Sheet
2011|Agilent Technologies|Brochures and specifications
Agilent 7000B Triple Quadrupole GC/MS System Data Sheet Agilent is leading the way by introducing IDL, Instrument Detection Limit, as a new metric for meaningful indication of system sensitivity. In MS/MS baselines with very little noise, the dubious selection of…
Key words
mrm, mrmpci, pcifilaments, filamentsnci, ncielectronic, electronicmodes, modesidl, idlpneumatic, pneumaticmore, morecollision, collisiontriple, triplesheet, sheetaxis, axiscustomary, customaryquadrupole
Agilent 7000C Triple QuadrupoleGC/MS System - Data Sheet
2013|Agilent Technologies|Brochures and specifications
Agilent 7000C Triple Quadrupole GC/MS System Data Sheet The 7890B Gas Chromatograph and 7000C Mass Spectrometer is the most sensitive GC/MS/MS system with the lowest, 4 fg Octafluoronaphthalene Instrument Detection Level (IDL) specification. The 4fg IDL is demonstrated upon installation,…
Key words
mrm, mrmidl, idlfilaments, filamentspci, pcisystem, systemcollision, collisionsheet, sheetaxis, axisquadrupole, quadrupolehed, hediris, irisspecifications, specificationstradition, traditionagilent, agilentdual
Agilent 7000D Triple Quadrupole GC/MS System - Data Sheet
2016|Agilent Technologies|Brochures and specifications
Agilent 7000D Triple Quadrupole GC/MS System Data Sheet The Agilent 7890B Gas Chromatograph combined with an Agilent 7000D Mass Spectrometer is the best choice for routine GC/MS/MS analysis with a low 4 fg Octafluoronaphthalene Instrument Detection Level (IDL) specification. The…
Key words
mrm, mrmparameter, parametervalue, valuefilaments, filamentsramps, rampstransition, transitionpci, pciidl, idlspecifications, specificationscollision, collisionaxis, axisproprietary, proprietarysystem, systemvent, ventsource
Agilent 7010B Triple Quadrupole GC/MS System - Data Sheet
2016|Agilent Technologies|Brochures and specifications
Agilent 7010B Triple Quadrupole GC/MS System Data Sheet The Agilent 7890B Gas Chromatograph combined with an Agilent 7010B Mass Spectrometer is the most sensitive GC/MS/MS system with the lowest, 0.5 fg Octafluoronaphthalene Instrument Detection Limit (IDL) specification. The 0.5 fg…
Key words
mrm, mrmparameter, parametervalue, valuefilaments, filamentsramps, rampstransition, transitionpci, pciidl, idlspecifications, specificationscollision, collisionaxis, axisproprietary, proprietarysystem, systemvent, ventsource