Utilization of GCxGC-TOFMS to Screen for Potential Metabolite Differences in Pooled Samples from Lean, Fat, and Obese Zucker Rat Plasma
Posters | 2011 | LECOInstrumentation
Comprehensive two-dimensional gas chromatography combined with time-of-flight mass spectrometry (GCxGC-TOFMS) addresses challenges in metabolite profiling of complex biological matrices such as blood plasma. By dramatically increasing chromatographic peak capacity and improving resolution of coeluting compounds, this technique enables sensitive detection and reliable identification of low-abundance metabolites. Such capabilities are essential for biomarker discovery, metabolic phenotyping, and quality control in research and clinical laboratories.
This study employed GCxGC-TOFMS to compare pooled plasma samples from lean, fatty, and diabetic obese Zucker rats. The goal was to screen for semi-quantitative differences in derivatized small molecule metabolites across health states, demonstrating the method’s capacity for fast screening of large sample sets and identifying potential biomarkers related to obesity and metabolic disorders.
GCxGC-TOFMS offers rapid, high-resolution screening of complex sample sets, reducing analysis time and sample consumption. The enhanced separation and fast acquisition facilitate reliable library matching and semi-quantitative comparisons across sample pools. This approach is well suited for metabolic phenotyping, biomarker discovery, and quality control in pharmaceutical and clinical research.
This proof-of-concept study demonstrates that GCxGC-TOFMS is an effective screening tool for detecting semi-quantitative metabolite variations in pooled plasma samples. Its enhanced chromatographic resolution and rapid mass spectral acquisition enable discovery of potential biomarkers associated with metabolic states, providing a valuable resource for research in health and disease.
GCxGC, GC/MSD, GC/TOF
IndustriesMetabolomics
ManufacturerLECO
Summary
Significance of the Topic
Comprehensive two-dimensional gas chromatography combined with time-of-flight mass spectrometry (GCxGC-TOFMS) addresses challenges in metabolite profiling of complex biological matrices such as blood plasma. By dramatically increasing chromatographic peak capacity and improving resolution of coeluting compounds, this technique enables sensitive detection and reliable identification of low-abundance metabolites. Such capabilities are essential for biomarker discovery, metabolic phenotyping, and quality control in research and clinical laboratories.
Objectives and Study Overview
This study employed GCxGC-TOFMS to compare pooled plasma samples from lean, fatty, and diabetic obese Zucker rats. The goal was to screen for semi-quantitative differences in derivatized small molecule metabolites across health states, demonstrating the method’s capacity for fast screening of large sample sets and identifying potential biomarkers related to obesity and metabolic disorders.
Methodology
- Sample preparation involved protein removal using 5000 MWCO filters, drying under vacuum, and derivatization with BSTFA at 60°C overnight.
- GCxGC separation utilized an Agilent 7890 GC with a dual-stage thermal modulator, primary Rxi-5Sil MS column (30 m×0.25 mm×0.25 µm) and secondary Rxi-17Sil MS column (1.24 m×0.15 mm×0.15 µm), helium carrier gas at 1.5 mL/min.
- Temperature program: 70°C (0.5 min) to 305°C at 6°C/min; secondary column ramp offset +5°C; total run time 44.7 min.
- TOFMS detection was performed on a LECO Pegasus 4D at 150 spectra/s over 45–750 m/z, ion source 240°C, electron energy –70 eV.
- Data processing included signal deconvolution and library searches against Max Planck, Fiehn Rtx5, and NIST spectral libraries.
Instrumentation
- Gas chromatograph: Agilent 7890 GC with LECO dual-stage quad-jet thermal modulator.
- Mass spectrometer: LECO Pegasus 4D TOFMS.
Key Findings and Discussion
- Twelve metabolites exhibited significant peak area variations among lean, fatty, and obese pools. Leucine was absent in lean but enriched in fatty and obese samples.
- Penta-TMS-Glucopyranose levels increased progressively from lean to fatty to obese groups, consistent with altered glucose metabolism.
- Derivatized glycine was detected only in fatty and obese pools, indicating pathway shifts linked to lipid accumulation.
- N,O-TMS-Proline showed upregulation in fatty plasma followed by downregulation in obese diabetic samples, suggesting complex regulation.
- Tris-TMS-L-Threonine exhibited a similar trend of increase in fatty and decrease in obese pools.
- Overlay of 2D contour plots demonstrated resolution of coeluting analytes that one-dimensional GC could not separate.
Benefits and Practical Applications
GCxGC-TOFMS offers rapid, high-resolution screening of complex sample sets, reducing analysis time and sample consumption. The enhanced separation and fast acquisition facilitate reliable library matching and semi-quantitative comparisons across sample pools. This approach is well suited for metabolic phenotyping, biomarker discovery, and quality control in pharmaceutical and clinical research.
Future Trends and Potential Applications
- Integration with high-resolution accurate mass spectrometry and advanced data analytics (e.g., machine learning) for deeper metabolomic insights.
- Development of targeted quantitation workflows and expanded spectral libraries for diverse biological matrices.
- Automation of sample preparation and data processing to support high-throughput studies.
- Applications in clinical diagnostics, nutritional research, environmental metabolomics, and personalized medicine.
Conclusion
This proof-of-concept study demonstrates that GCxGC-TOFMS is an effective screening tool for detecting semi-quantitative metabolite variations in pooled plasma samples. Its enhanced chromatographic resolution and rapid mass spectral acquisition enable discovery of potential biomarkers associated with metabolic states, providing a valuable resource for research in health and disease.
References
- Max Planck Mass Spectral Library
- Fiehn Rtx5 Mass Spectral Library
- NIST Mass Spectral Library
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Characterization of Electron Ionization and Chemical Ionization on a Novel High Resolution Gas Chromatography Time-of-Flight Mass Spectrometer—Tools for the Identification of Unknown Metabolites
|Agilent Technologies|Posters
Utilization of GCxGC-TOFMS to Screen for Potential Metabolite Differences in Pooled Samples from Lean, Fat, and Obese Zucker Rat Plasma John Heim, Jeff Patrick, and Joe Binkley • Saint Joseph, MI USA OBJECTIVES Demonstrate the enhanced detection and increased peak…
Key words
pooled, pooledobese, obeselean, leanfat, fatgcxgc, gcxgcreplib, replibtofms, tofmsuniquemass, uniquemasspool, poolname, namepools, poolsburied, buriedsimilarity, similarityresolves, resolvesglucopyranose
Utilization of GCxGC-TOFMS to Screen for Potential Metabolite Differences in Pooled Plasma Samples from Lean, Fat, and Obese Rats
2011|Agilent Technologies|Applications
Utilization of GCxGC-TOFMS to Screen for Potential Metabolite Differences in Pooled Plasma Samples from Lean, Fat, and Obese Rats LECO Corporation; Saint Joseph, Michigan USA Keywords: GCxGC, Metabolomics, Biomarkers 1. Introduction 2. Experimental Conditions This GCxGC-TOFMS research presents the comparison…
Key words
pooled, pooledobese, obeselean, leanfat, fatpools, poolsgcxgc, gcxgcuniquemass, uniquemasspool, pooltofms, tofmsname, namesimilarity, similarityzucker, zuckermetabolite, metaboliteglucopyranose, glucopyranosetms
Evaluation of Metabolite Variation by a Pooled Sample Approach between Normal Control and Traumatic Brain Injury Mice Using GCxGC-TOFMS with Data Analysis Using a Software Driven Reference Feature
2013|Agilent Technologies|Posters
Evaluation of Metabolite Variation by a Pooled Sample Approach between Normal Control and Traumatic Brain Injury Mice Using GCxGC-TOFMS with Data Analysis Using a Software Driven Reference Feature John Heim, Joe Binkley, and Liz Humston-Fulmer | LECO Corporation, Saint Joseph,…
Key words
pooled, pooledtraumatic, traumaticgcxgc, gcxgcmetabolite, metabolitebrain, braintofms, tofmsinjury, injurytbi, tbimainlib, mainlibnormal, normalpools, poolsreference, referencecontrol, controlctrl, ctrlvariations
GCxGC-TOFMS Analysis of Mouse Plasma Extracts to Determine Metabolite Profiles From a Traumatic Brain Injury Study
2013|Agilent Technologies|Posters
GCxGC-TOFMS Analysis of Mouse Plasma Extracts to Determine Metabolite Profiles From a Traumatic Brain Injury Study John Heim, Liz Humston-Fulmer, and Joe Binkley | LECO Corporation, Saint Joseph, MI USA INTRODUCTION METHODS Comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry has…
Key words
gcxgc, gcxgctofms, tofmstraumatic, traumaticbrain, braincomprehensive, comprehensivemouse, mousevolatile, volatiledimensional, dimensionalflight, flightinjury, injurydifferentiate, differentiateheptatms, heptatmsosphate, osphatetatms, tatmsillustrates