GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

GCxGC-TOFMS Analysis of Mouse Plasma Extracts to Determine Metabolite Profiles From a Traumatic Brain Injury Study

Posters | 2013 | LECOInstrumentation
GCxGC, GC/MSD, GC/TOF
Industries
Metabolomics, Clinical Research
Manufacturer
Agilent Technologies, GERSTEL, LECO

Summary

Importance of the Topic


Comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GCxGC-TOFMS) offers unprecedented resolving power for volatile and semi-volatile metabolites in complex biological samples. In the context of traumatic brain injury (TBI), detailed metabolite profiling can reveal biomarkers associated with disease progression and recovery. The high peak capacity and deconvolution capabilities of GCxGC-TOFMS make it particularly valuable for distinguishing subtle biochemical changes in plasma extracts that one-dimensional methods may overlook.

Study Objectives and Overview


This work aimed to evaluate a GCxGC-TOFMS platform for comparative metabolomic analysis of mouse plasma from TBI and control groups. By applying optimized chromatographic separation and mass spectral deconvolution, the study sought to identify small molecule differences that could serve as potential biomarkers of neural injury. Four TBI and four healthy control plasma samples were prepared, derivatized, and analyzed in triplicate to ensure robust data acquisition.

Methodology and Instrumentation


Plasma extracts were spiked with an internal standard mixture, precipitated with methanol, dried, and derivatized with N,O-bis(trimethylsilyl)trifluoroacetamide plus 1% TMCS at 60 °C. Analytical runs were carried out on a LECO Pegasus 4D GCxGC-TOFMS system featuring a primary Rxi-5SilMS column (30 m × 0.25 mm × 0.25 μm) and a secondary Rxi-17Sil-MS column (1.25 m × 0.25 mm × 0.25 μm). A dual-stage quad-jet modulator with a 4 s modulation period enabled enhanced chromatographic resolution over a 56.5 min temperature program. TOFMS detection covered m/z 45–700 at 200 spectra/s, with an acquisition delay of 450 s and an ion source temperature of 230 °C.

Instrumentation Used


  • Gas chromatograph: Agilent 7890 with LECO dual-stage quad-jet thermal modulator and GERSTEL MPS2 autosampler
  • Primary column: Rxi-5SilMS (30 m × 0.25 mm i.d. × 0.25 μm)
  • Secondary column: Rxi-17Sil-MS (1.25 m × 0.25 mm i.d. × 0.25 μm)
  • Mass spectrometer: LECO Pegasus 4D TOFMS
  • Carrier gas: Helium at 1.5 mL/min
  • Derivatization reagent: BSTFA plus 1% TMCS

Main Results and Discussion


GCxGC delivered a peak capacity exceeding 1000 with signal-to-noise ratios above 300, facilitating consistent detection of over one thousand features per sample. True Signal Deconvolution successfully resolved coeluting analytes within 80 ms windows. Comparative analysis highlighted sixteen metabolites with significant abundance changes between TBI and controls, predominantly trimethylsilyl-derivatized amino acids such as alanine, valine, isoleucine, serine, threonine, methionine, proline, aspartic acid and glutamic acid, together with sugar derivatives and inositol phosphates. Elevated levels of excitatory amino acids in TBI samples align with known neuropathological responses.

Benefits and Practical Applications


  • Enhanced chromatographic resolution enables detection of low-abundance metabolites obscured in one-dimensional GC
  • High-throughput triplicate analyses provide robust relative quantitation for biomarker discovery
  • Accurate deconvolution of mass spectra supports confident library matching in complex matrices
  • Applicability extends to disease profiling, pharmaceutical research and quality control in bioanalysis

Future Trends and Potential Applications


  • Integration with advanced data analytics and machine learning for pattern recognition
  • Automation of sample preparation and derivatization to boost throughput
  • Coupling with other omics platforms for multi-dimensional biochemical insight
  • Clinical translation for monitoring metabolic states and therapeutic efficacy

Conclusion


This study demonstrates that GCxGC-TOFMS is a powerful analytical platform for comprehensive profiling of small molecules in plasma. The approach successfully differentiates metabolic signatures associated with traumatic brain injury, showcasing its potential for biomarker discovery and mechanistic investigations of disease.

References


  • A Scafidi, J OBrien, I Hopkins, C Robertson, G Fiskum, M McKenna; Journal of Neurochemistry, 2009, 109, 189-197. Delayed Cerebral Oxidative Glucose Metabolism After Traumatic Brain Injury in Young Rats
  • P Nilsson, L Hillered, U Ponten, U Ungerstedt; Journal of Cerebral Blood Flow and Metabolism, 1990, 10, 631-637. Changes in Cortical Extracellular Levels of Energy-Related Metabolites and Amino Acids Following Concussive Brain Injury in Rats

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Evaluation of Metabolite Variation by a Pooled Sample Approach between Normal Control and Traumatic Brain Injury Mice Using GCxGC-TOFMS with Data Analysis Using a Software Driven Reference Feature
Evaluation of Metabolite Variation by a Pooled Sample Approach between Normal Control and Traumatic Brain Injury Mice Using GCxGC-TOFMS with Data Analysis Using a Software Driven Reference Feature John Heim, Joe Binkley, and Liz Humston-Fulmer | LECO Corporation, Saint Joseph,…
Key words
pooled, pooledtraumatic, traumaticgcxgc, gcxgcmetabolite, metabolitebrain, braintofms, tofmsinjury, injurytbi, tbimainlib, mainlibnormal, normalpools, poolsreference, referencecontrol, controlctrl, ctrlvariations
Anti-Doping Control Using Comprehensive Multidimensional Gas Chromatography Time-of-Flight Mass Spectrometry (GCxGC-TOFMS) for Enhanced Detection of Anabolic Steroids in Urine
® Delivering the Right Results Anti-Doping Control Using Comprehensive Multidimensional Gas Chromatography Time-of-Flight Mass Spectrometry (GCxGC-TOFMS) for Enhanced Detection of Anabolic Steroids in Urine John Heim, Doug Staples, and Joe Binkley • LECO Corporation, St. Joseph, MI Steroid Standards were…
Key words
gcxgc, gcxgctofms, tofmsanabolic, anabolicsteroids, steroidssteroid, steroidsteering, steeringcapacity, capacityenhanced, enhancedanalyte, analytecomprehensive, comprehensivedimensional, dimensionalturbomolecular, turbomolecularflight, flightdoping, dopingmens
Enhanced Detection and Separation of Anabolic Steroids for Anti-Doping Control Screening by Comprehensive Two- Dimensional Gas Chromatography Time-of-Flight Mass Spectrometry (GCxGC-TOFMS)
® Enhanced Detection and Separation of Anabolic Steroids for Anti-Doping Control Screening by Comprehensive TwoDimensional Gas Chromatography Time-of-Flight Mass Spectrometry (GCxGC-TOFMS) John Heim • LECO Corporation; Saint Joseph, Michigan USA Key Words: GCxGC-TOFMS, Anabolic Steroids, World Anti-Doping Agency Stanozolol (Winstrol),…
Key words
gcxgc, gcxgcanabolic, anabolictofms, tofmssteroid, steroidsteroids, steroidsdimensional, dimensionalstanozolol, stanozololmass, massfive, fiveflight, flightcomprehensive, comprehensivepractical, practicaltrace, tracedoping, dopingurine
Utilization of GCxGC-TOFMS to Screen for Potential Metabolite Differences in Pooled Samples from Lean, Fat, and Obese Zucker Rat Plasma
Utilization of GCxGC-TOFMS to Screen for Potential Metabolite Differences in Pooled Samples from Lean, Fat, and Obese Zucker Rat Plasma John Heim, Jeff Patrick, and Joe Binkley • Saint Joseph, MI USA OBJECTIVES Demonstrate the enhanced detection and increased peak…
Key words
pooled, pooledobese, obeselean, leanfat, fatgcxgc, gcxgcreplib, replibtofms, tofmsuniquemass, uniquemasspool, poolname, nameburied, buriedpools, poolssimilarity, similarityresolves, resolvesglucopyranose
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike