EPA Method 525.3 Internal and Surrogate Standards on Rxi®-5Sil MS

Applications |  | RestekInstrumentation
GC/MSD, GC/SQ, GC columns, Consumables
Industries
Environmental
Manufacturer
Agilent Technologies, Restek

Summary

Significance of the Method


Accurate quantification of trace organic contaminants in water is essential for environmental monitoring and regulatory compliance. The use of internal and surrogate standards in EPA Method 525.3 enhances data quality by correcting for extraction losses, instrument drift, and matrix effects. Standardized procedures ensure reliable detection of pesticides, PCBs, PAHs, and other priority pollutants at low concentration levels.

Objectives and Overview


This application note illustrates the chromatographic separation and mass spectral detection of internal and surrogate standards on a 30 m Rxi®-5Sil MS column. The goals are to demonstrate retention behavior, peak resolution, and reproducibility under EPA Method 525.3 conditions.

Methodology and Instrumentation


The method employs an Agilent 7890B gas chromatograph coupled to a 5977A mass selective detector operated in scan mode. A 30 meter Rxi-5Sil MS column with 0.25 mm internal diameter and 0.25 micrometer film thickness was used. Sample preparation follows EPA Method 525.3 protocols with ethyl acetate as diluent and spiking of surrogate and internal standards at 2 micrograms per milliliter.

Used Instrumentation


  • Gas chromatograph Agilent 7890B with pulsed splitless injection
  • Mass spectrometer Agilent 5977A MSD in scan mode
  • Rxi-5Sil MS column, 30 m x 0.25 mm ID x 0.25 µm film
  • Premium 4 mm single taper inlet liner with wool

Main Results and Discussion


Retention times for seven standards ranged from approximately 7 to 26 minutes. Early eluting compounds included 1,3-dimethyl-2-nitrobenzene and acenaphthene-d10, while high boiling point analytes such as benzo[a]pyrene-d12 eluted near 26 minutes. Chromatographic peaks exhibited sharp shapes and baseline separation, confirming the suitability of the temperature program: initial hold at 70 °C, ramp to 200 °C at 10 °C per minute, then to 320 °C at 7 °C per minute. He carrier gas at 1.2 mL per minute constant flow supported efficient mass transfer and minimal peak broadening.

Benefits and Practical Applications


This configuration allows reliable quantitation of a broad range of EPA target analytes in drinking, ground, and surface water matrices. The use of isotopically labeled standards ensures accurate recovery correction and quality assurance in routine monitoring, QA QC laboratories, and environmental research.

Future Trends and Potential Uses


Advancements in stationary phases may further improve resolution of complex mixtures, while high resolution mass spectrometry could enhance selectivity and sensitivity. Miniaturized GC interfaces and automated sample preparation systems promise higher throughput and reduced solvent consumption. Emerging microextraction techniques will complement standard protocols for ultra trace analysis.

Conclusion


The combination of a 30 m Rxi-5Sil MS column with a pulsed splitless injection and MS detection provides robust performance for EPA Method 525.3 analyses. The selected internal and surrogate standards cover a wide polarity and volatility range, ensuring comprehensive monitoring of priority contaminants in water.

Reference


EPA Method 525.3 Internal and Surrogate Standards on Rxi-5Sil MS, Restek Corporation 2024

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
EPA Method 525.3 PCB Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi®-5Sil MS
EPA Method 525.3 PCB Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi®-5Sil MS 8 6 19 2 18 1 3 6.00 8.00 10.00 4 12.00 21 5 7 14.00 9 10 11 12 16.00 18.00 Time (min) 13…
Key words
goup, goupscan, scandftpp, dftppmin, minamu, amuextractor, extractorscans, scansdelay, delayethyl, ethylsec, secacetate, acetatestart, starttime, timeoven, ovenquadrupole
EPA Method 525.3 OPP Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi®-5Sil MS
EPA Method 525.3 OPP Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi®-5Sil MS 5 m/z = 127.00 m/z = 109.00 m/z = 192.00 4 10 11 6 23 22 24 2 12 7 3 1 17 9 6.00…
Key words
goup, goupscan, scandftpp, dftppmin, minamu, amuextractor, extractorscans, scansdelay, delayethyl, ethylsec, secacetate, acetatestart, starttime, timeoven, ovenquadrupole
EPA Method 525.3 OCP Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi®-5Sil MS
EPA Method 525.3 OCP Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi®-5Sil MS 8,9 11 3 32 16,17 1 6 5 7 4 36 10 12 13 2 6.00 31 20,21 8.00 10.00 12.00 14.00 14 15 16.00…
Key words
goup, goupscan, scandftpp, dftppmin, minamu, amuextractor, extractorscans, scansdelay, delayethyl, ethylsec, secacetate, acetatestart, starttime, timeoven, ovenquadrupole
EPA Method 525.3 ONP Calibration Standard (with 525.3 Internal and Surrogate Standards) on the Rxi®-5Sil MS
EPA Method 525.3 ONP Calibration Standard (with 525.3 Internal and Surrogate Standards) on the Rxi®-5Sil MS 21 23 m/z 200.00 m/z 215.00 m/z 214.00 m/z 229.00 Cyanazine Trailing Factor = 1.34 19 m/z 201.00 m/z 173.00 m/z 225.00 m/z 68.00…
Key words
goup, goupscan, scanmin, mindftpp, dftpppeaks, peaksamu, amuextractor, extractorscans, scansdelay, delayethyl, ethylsec, secacetate, acetatestart, starttime, timeoven
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike