EPA Method 525.3 PCB Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi®-5Sil MS
Applications | | RestekInstrumentation
GC/MSD, GC/SQ, GC columns, Consumables
IndustriesEnvironmental
ManufacturerAgilent Technologies, Restek
Summary
Importance of Topic
- Reliable calibration of polychlorinated biphenyls (PCBs) is essential for accurate environmental monitoring and regulatory compliance.
- Standardized methods such as EPA Method 525.3 ensure consistency across laboratories and long-term data comparability.
Aims and Overview of the Study
- To present a calibration standard for PCB congeners using EPA Method 525.3 on an Rxi-5Sil MS column.
- To demonstrate retention time separation, surrogate and internal standard performance, and overall method robustness.
Methodology and Instrumentation
- Sample: EPA Method 525.3 PCB calibration standard prepared in ethyl acetate at 2 µg/mL.
- Column: Rxi-5Sil MS, 30 m × 0.25 mm ID, 0.25 µm film thickness.
- Injection: 1 µL pulsed splitless injection (30 psi pulse, 1 min hold) at 275 °C with wool-packed liner.
- Oven Program: 70 °C (1 min) to 200 °C at 10 °C/min, then to 320 °C at 7 °C/min (3 min hold).
- Carrier Gas: Helium at constant flow of 1.2 mL/min.
- Detector: Quadrupole GC–MS in full scan mode (45–550 amu at 5.5 scans/sec) with transfer line at 280 °C, source at 350 °C, quadrupole at 200 °C, EI ionization.
Main Results and Discussion
- Twenty-one peaks, including internal standards (IS), surrogate standards (SS), and PCB congeners, were baseline separated between 7.03 and 26.27 min.
- Surrogates 1,3-Dimethyl-2-nitrobenzene and triphenyl phosphate defined early and mid elution, while benzo[a]pyrene-D12 marked the late region.
- Retention time repeatability was within acceptable limits for quantitative analysis of mono- through heptachlorobiphenyls.
Benefits and Practical Applications
- Ensures precise quantitation of PCBs in water, soil, and air matrices for environmental compliance.
- Improves detection reliability through use of isotopically labeled internal and surrogate standards.
- Facilitates method transferability between laboratories following EPA guidelines.
Future Trends and Potential Applications
- Integration with high-resolution mass spectrometry for enhanced congener identification and quantitation.
- Development of automated data processing pipelines to streamline PCB monitoring workflows.
- Expansion to emerging persistent organic pollutants with similar GC–MS protocols.
Conclusion
- The EPA Method 525.3 calibration standard on an Rxi-5Sil MS column delivers robust separation and accurate quantitation of PCB congeners.
- Use of multiple internal and surrogate standards enhances method reliability for environmental analyses.
Reference
- EPA Method 525.3: Determination of Organic Compounds in Drinking Water by Solid Phase Extraction and GC-MS.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
EPA Method 525.3 Full Analyte List on Rxi®-5Sil MS
|Agilent Technologies|Applications
EPA Method 525.3 Full Analyte List on Rxi®-5Sil MS Peaks 1. Diisopropyl methylphosphonate (DIMP) 2. Isophorone 3. 1,3-Dimethyl-2-nitrobenzene (SS) 4. Dichlorvos 5. Hexachlorocyclopentadiene (HCCPD) 6. S-Ethyl dipropylthiocarbamate (EPTC) 7. Mevinphos I 8. Mevinphos II 9. Butylate 10. Vernolate 11. Dimethylphthalate…
Key words
min, mingoup, goupscan, scanpeaks, peaksdftpp, dftppamu, amuextractor, extractorscans, scansdelay, delayethyl, ethylsec, secacetate, acetatestart, starttime, timeoven
PCB Congener Mix (EPA Method 8082A) on the Rtx®-PCB Column
|Agilent Technologies|Applications
PCB Congener Mix (EPA Method 8082A) on the Rtx®-PCB Column Peaks 1. 2-Chlorobiphenyl (PCB-1) 2. 2,3-Dichlorobiphenyl (PCB-5) 3. 2,2',5-Trichlorobiphenyl (PCB-18) 4. 2,4',5-Trichlorobiphenyl (PCB-31) 5. 2,2',5,5'-Tetrachlorobiphenyl (PCB-52) 6. 2,2',3,5'-Tetrachlorobiphenyl (PCB-44) 7. 2,3',4,4'-Tetrachlorobiphenyl (PCB-66) 8. 2,2',4,5,5'-Pentachlorobiphenyl (PCB-101) 9. 2,2',3,4,5'-Pentachlorobiphenyl (PCB-87) Peaks 10.…
Key words
pos, posisooctane, isooctanescan, scanpeaks, peaksamu, amuscans, scansmin, minsec, secgroup, groupstart, starttime, timeoven, ovenquadrupole, quadrupoletransfer, transferline
Extraction of Semi-volatile Organic Compounds in Drinking Water with NEW Atlantic® ReadyDisk DVB Solid Phase Extraction Disks in Compliance with EPA Method 525.3
2019|Agilent Technologies|Applications
Application Note AN900 Extraction of Semi-volatile Organic Compounds in Drinking Water with NEW Atlantic ReadyDisk DVB | Page 1 ® Extraction of Semi-volatile Organic Compounds in Drinking Water with NEW Atlantic ReadyDisk DVB Solid Phase Extraction Disks in Compliance with…
Key words
readydisk, readydiskatlantic, atlanticdvb, dvbdisks, diskssoak, soaktime, timebenzo, benzophthalate, phthalateextraction, extractionhch, hchstep, stepsolvent, solventsaturation, saturationwere, wereendosulfan
PCB and Environmental Neat Standards - Your essential resource for Agilent ULTRA chemical standards
2019|Agilent Technologies|Brochures and specifications
PCB and Environmental Neat Standards Your essential resource for Agilent ULTRA chemical standards Table of contents Introduction 3 Aroclors 21 About Agilent standards 3 Commercial PCBs 21 Products 3 Markets 3 PCM, Metabolites, and Terphenyls 23 Custom products 3 Hydroxylated…
Key words
pcb, pcbneat, neatcongeners, congenerscompound, compoundstandards, standardsenvironmental, environmentalcontinued, continueddescription, descriptionsee, seebiphenyls, biphenylsbenzo, benzopolychlorinated, polychlorinatedmethyl, methylphthalate, phthalatemass