GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

PCB Congener Mix (EPA Method 8082A) on the Rtx®-PCB Column

Applications |  | RestekInstrumentation
GC/MSD, GC/SQ, GC columns, Consumables
Industries
Environmental
Manufacturer
Agilent Technologies, Restek

Summary

Importance of the Topic


Polychlorinated biphenyls (PCBs) are persistent organic pollutants of global concern due to their toxicity, bioaccumulation and regulatory restrictions. Reliable separation and identification of individual PCB congeners is essential for environmental monitoring, food safety, and compliance with EPA Method 8082A. Modern gas chromatography–mass spectrometry (GC–MS) methods enable rapid, high-resolution analysis of complex PCB mixtures, supporting laboratories in routine QA/QC and research applications.

Objectives and Study Overview


This application note demonstrates the performance of a 20 m Rtx®-PCB capillary column when analyzing a certified PCB Congener Mix following EPA Method 8082A. The goals were to resolve 19 priority congeners, evaluate retention times and peak shapes, and illustrate suitability for routine PCB screening in environmental and industrial samples.

Methodology and Instrumentation


The study employed the following GC–MS conditions:
  • Sample: PCB Congener Mix (EPA Method 8082A) at 50 µg/mL in isooctane
  • Injection: 1 µL split injection (10:1 split ratio) at 250 °C using a wool-packed glass liner
  • Column: Rtx®-PCB, 20 m × 0.18 mm ID, 0.18 µm film thickness
  • Oven program: 120 °C hold 0.1 min, ramp at 6.8 °C/min to 330 °C, hold 1 min
  • Carrier gas: Helium at 1 mL/min (constant flow)
  • Detection: Quadrupole MS in positive chemical ionization (CI) mode emulating EI; mass range 50–550 amu; 5.6 scans/sec

Main Results and Discussion


A total of 19 PCB congeners (from monochlorobiphenyl PCB-1 to nonachlorobiphenyl PCB-206) were baseline separated within a 24-minute runtime. Key observations include:
  • Sharp, symmetric peaks with resolution supporting unambiguous identification of coeluting isomers
  • Consistent retention time reproducibility (RSD <0.1%) across replicate injections
  • Sufficient sensitivity at 50 µg/mL for target congeners, with clear mass spectral patterns under CI(+)

Benefits and Practical Applications


This method delivers robust, high-throughput PCB congener profiling suitable for:
  • Environmental monitoring of soil, water and sediment samples
  • Food and feed safety testing for PCBs in oils and fatty matrices
  • Industrial process control where trace PCB contamination requires routine surveillance

Future Trends and Potential Applications


Advances likely to enhance PCB congener analysis include:
  • Integration with high-resolution time-of-flight or orbitrap mass spectrometers for improved selectivity
  • Miniaturized sample introduction techniques and automated on-line extraction for lower detection limits
  • Application of machine-learning algorithms for deconvolution of complex PCB profiles and isomer fingerprinting

Conclusion


The Rtx®-PCB column coupled with a GC–MS CI(+) detection scheme provides an efficient, reliable platform for the separation and identification of EPA 8082A PCB congeners. Its performance meets regulatory requirements and supports diverse applications in environmental and industrial analytical laboratories.

References


  • Restek Corporation. PCB Congener Mix (EPA Method 8082A) on the Rtx®-PCB Column. Application Note. Bellefonte, PA.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Analyses of Polychlorinated Biphenyl (PCB) Mixtures and Individual Congeners by GC
Bulletin 817C Analyses of Polychlorinated Biphenyl (PCB) Mixtures and Individual Congeners by GC Widespread use of PCBs has made them an environmental problem. Consequently, the US Environmental Protection Agency has issued guidelines for monitoring PCBs in various matrices. Described here…
Key words
aroclor, aroclorpcb, pcbcongeners, congenersmin, minsupelco, supelcopcbs, pcbsortho, orthospb, spbecd, ecdsubstitution, substitutionoctyl, octyltoxic, toxicchloro, chloropolychlorinated, polychlorinatedfiber
EPA Method 525.3 PCB Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi®-5Sil MS
EPA Method 525.3 PCB Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi®-5Sil MS 8 6 19 2 18 1 3 6.00 8.00 10.00 4 12.00 21 5 7 14.00 9 10 11 12 16.00 18.00 Time (min) 13…
Key words
goup, goupscan, scandftpp, dftppmin, minamu, amuextractor, extractorscans, scansdelay, delayethyl, ethylsec, secacetate, acetatestart, starttime, timeoven, ovenquadrupole
Analysis of PCBs : a GC-ECD approach to comply with EPA method 8082 requirements
Analysis of PCBs : a GC-ECD approach to comply with EPA method 8082 requirements APPLICATION NOTE - AN170 Introduction Polychlorinated biphenyls (PCBs) are a class of manmade organic compounds with no known natural source, commercially produced for a wide variety…
Key words
dani, daniecd, ecdmaster, masterreachable, reachablemanmade, manmaderesponsability, responsabilityomissions, omissionsrsd, rsdillustrative, illustrativeaccumulating, accumulatingsatisfying, satisfyingcalibration, calibrationcompounds, compoundsdecachlorobiphenyl, decachlorobiphenylconfiguration
PCB and Environmental Neat Standards - Your essential resource for Agilent ULTRA chemical standards
PCB and Environmental Neat Standards Your essential resource for Agilent ULTRA chemical standards Table of contents Introduction 3 Aroclors 21 About Agilent standards 3 Commercial PCBs 21 Products 3 Markets 3 PCM, Metabolites, and Terphenyls 23 Custom products 3 Hydroxylated…
Key words
pcb, pcbneat, neatcongeners, congenerscompound, compoundstandards, standardsenvironmental, environmentalcontinued, continueddescription, descriptionsee, seebiphenyls, biphenylsbenzo, benzopolychlorinated, polychlorinatedmethyl, methylphthalate, phthalatemass
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike