Analysis of PCBs : a GC-ECD approach to comply with EPA method 8082 requirements

Applications |  | DANI InstrumentsInstrumentation
GC
Industries
Environmental
Manufacturer
DANI Instruments

Summary

Importance of the Topic


Polychlorinated biphenyls (PCBs) remain among the most persistent environmental pollutants due to their chemical stability and lipophilicity. Their widespread historical use in electrical fluids, flame retardants and plasticizers has led to global contamination. Monitoring PCB levels is critical for protecting human health and ecosystems, as these compounds bioaccumulate and impact immune, reproductive and endocrine systems.

Objectives and Study Overview


This application note describes the implementation of a gas chromatography–electron capture detection (GC-ECD) method in accordance with EPA Method 8082 for rapid, sensitive analysis of PCB congeners. The study evaluates chromatographic separation, calibration linearity and repeatability using a standard PCB mixture spanning a broad concentration range.

Methodology and Instrumentation


Standard solutions of 19 PCB congeners were prepared in n-hexane at concentrations between 5 and 500 ng/mL. Decachlorobiphenyl served as internal standard and was added automatically by a liquid autosampler. Chromatographic separation was achieved on a Restek Rxi-5MS capillary column (20 m × 0.18 mm × 0.18 µm) with helium carrier gas at constant flow (0.8 mL/min). The oven program ramped from 120 °C to 300 °C at 12 °C/min, with a 4-minute hold. Injector temperature was set at 280 °C, split ratio 1:20, and injection volume 1 µL. The ECD operated at 320 °C with a carrier flow of 30 mL/min and acquisition rate of 25 Hz.

Used Instrumentation


  • Gas chromatograph equipped with electron capture detector (GC-ECD)
  • Restek Rxi-5MS capillary column (20 m × 0.18 mm × 0.18 µm)
  • DANI Master AS liquid autosampler
  • Helium as carrier gas

Main Results and Discussion


Chromatographic separation of all congeners was completed in under 15 minutes, demonstrating rapid analysis suitable for high-throughput laboratories. Calibration curves over seven concentration levels (5–500 ng/mL) exhibited excellent linearity, with R² values ranging from 0.9964 to 0.9999. Repeatability tests (five injections at 200 ng/mL) produced relative standard deviations below 3% for peak area and height, and under 0.04% for retention time, confirming the method’s precision. Detection limits are within the parts-per-billion range, meeting EPA requirements.

Benefits and Practical Applications


  • High specificity and sensitivity for trace-level PCBs
  • Rapid analysis (sub-15-minute runtime) for increased sample throughput
  • Robust repeatability suitable for regulatory compliance
  • Automated internal standard addition for improved accuracy

Future Trends and Applications


Advances in detector technology and column chemistries may further lower detection limits and enhance congener resolution. Integration with mass spectrometry (GC-MS) could provide confirmatory analysis and structural information. Miniaturized and field-deployable GC systems promise on-site PCB monitoring, while green chemistry approaches aim to reduce solvent use and energy consumption.

Conclusion


The GC-ECD method detailed here fulfills EPA Method 8082 criteria, offering rapid, reliable and sensitive analysis of PCB congeners. Its proven linearity, precision and low detection limits make it a valuable tool for environmental monitoring and quality control laboratories.

References


  • U.S. Environmental Protection Agency. Method 8082A: Polychlorinated Biphenyls (PCBs) by Gas Chromatography with Electron Capture Detection. 2007.
  • DANI Analitica. Application Note AN170: Analysis of PCBs – A GC-ECD Approach to Comply with EPA Method 8082 Requirements.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
PCB and Environmental Neat Standards - Your essential resource for Agilent ULTRA chemical standards
PCB and Environmental Neat Standards Your essential resource for Agilent ULTRA chemical standards Table of contents Introduction 3 Aroclors 21 About Agilent standards 3 Commercial PCBs 21 Products 3 Markets 3 PCM, Metabolites, and Terphenyls 23 Custom products 3 Hydroxylated…
Key words
pcb, pcbneat, neatcongeners, congenerscompound, compoundstandards, standardsenvironmental, environmentalcontinued, continueddescription, descriptionsee, seebiphenyls, biphenylsbenzo, benzopolychlorinated, polychlorinatedmethyl, methylphthalate, phthalatemass
Analyses of Polychlorinated Biphenyl (PCB) Mixtures and Individual Congeners by GC
Bulletin 817C Analyses of Polychlorinated Biphenyl (PCB) Mixtures and Individual Congeners by GC Widespread use of PCBs has made them an environmental problem. Consequently, the US Environmental Protection Agency has issued guidelines for monitoring PCBs in various matrices. Described here…
Key words
aroclor, aroclorpcb, pcbcongeners, congenersmin, minsupelco, supelcopcbs, pcbsortho, orthospb, spbecd, ecdsubstitution, substitutionoctyl, octyltoxic, toxicchloro, chloropolychlorinated, polychlorinatedfiber
Determination of Polychlorinated Biphenyls (PCBs) in Soils and Solid Waste by Accelerated Solvent Extraction and GC-MS/MS
CONSULENZE AMBIENTALI SPA Determination of Polychlorinated Biphenyls (PCBs) in Soils and Solid Waste by Accelerated Solvent Extraction and GC-MS/MS Fabrizio Galbiati, Thermo Fisher Scientific (Schweiz) AG, Reinach, Switzerland Luca Teli, Consulenze Ambientali SpA, Scanzorosciate, Italy Custom e r A ppli…
Key words
extraction, extractionaccelerated, acceleratedsolvent, solventpcb, pcbase, asepcbs, pcbsbiphenyls, biphenylspolychlorinated, polychlorinatedheptachlorobiphenyls, heptachlorobiphenylshexachlorobiphenyls, hexachlorobiphenylspentachlorobiphenyls, pentachlorobiphenylstetrachlorobiphenyls, tetrachlorobiphenylscleanup, cleanupfish, fishconsulenze
Analysis of Polychlorinated Biphenyls on the Agilent 8890 GC/5977B GC/MSD by Following the China HJ 743-2015 Method
Application Note Environmental Analysis of Polychlorinated Biphenyls on the Agilent 8890 GC/5977B GC/MSD by Following the China HJ 743-2015 Method Author Jie Zhang Agilent Technologies, Inc. Abstract This Application Note describes using the Agilent 8890 GC/5977B GC/MSD to analyze 18…
Key words
pcb, pcbsoil, soilpcbs, pcbsecology, ecologybiphenyls, biphenylspolychlorinated, polychlorinatedmsd, msddftpp, dftppcounts, countsenvironment, environmentfactor, factorrelative, relativetransformers, transformersresponse, responserecovery
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike