Volatile Organics US EPA Method 8021 Rtx®-VRX
Applications | | RestekInstrumentation
Volatile organic compounds (VOCs), including chlorinated hydrocarbons and aromatic solvents, pose significant environmental and health risks due to their persistence and toxicity. Reliable detection and quantification of these compounds in water are critical for regulatory compliance, pollution control, and safeguarding public health.
This study demonstrates a validated analytical protocol based on US EPA Method 8021 for simultaneous analysis of a comprehensive suite of VOCs in aqueous samples. The objectives include achieving low detection limits, broad analyte coverage, and robust chromatographic resolution.
The analytical workflow employs purge-and-trap sample concentration followed by capillary gas chromatography and dual detection. Key methodological parameters:
Baseline separation was achieved for over 60 VOCs, including chloromethane, dichloroethanes, trichloroethylene, benzene, toluene, xylenes, and naphthalene. The method yielded detection limits in the low ppb range, with consistent retention times and detector responses, demonstrating suitability for trace-level monitoring in wastewater.
Emerging developments include miniaturized purge-and-trap systems, real-time online monitoring, and coupling with mass spectrometry for enhanced selectivity. Integration with advanced data analytics and machine learning promises faster interpretation and proactive environmental management.
The described EPA Method 8021 configuration offers a robust, sensitive, and versatile platform for the analysis of volatile organics in aqueous matrices, meeting the needs of environmental laboratories and regulatory compliance programs.
Acknowledgement: µGold Tandem PID/HALL 2000 and Finnigan 9001 GC provided courtesy of Thermo Finnigan GC & GC/MS Division.
GC, Purge and Trap, GC columns, Consumables
IndustriesEnvironmental
ManufacturerThermo Fisher Scientific, Restek, Teledyne LABS
Summary
Volatile Organics Analysis by US EPA Method 8021
Significance of the Topic
Volatile organic compounds (VOCs), including chlorinated hydrocarbons and aromatic solvents, pose significant environmental and health risks due to their persistence and toxicity. Reliable detection and quantification of these compounds in water are critical for regulatory compliance, pollution control, and safeguarding public health.
Objectives and Study Overview
This study demonstrates a validated analytical protocol based on US EPA Method 8021 for simultaneous analysis of a comprehensive suite of VOCs in aqueous samples. The objectives include achieving low detection limits, broad analyte coverage, and robust chromatographic resolution.
Methodology and Instrumentation
The analytical workflow employs purge-and-trap sample concentration followed by capillary gas chromatography and dual detection. Key methodological parameters:
- Sample volume: 5 mL of reagent-grade water spiked with a multi-component VOC standard at 20 ppb.
- Purge conditions: 11 min at 40 mL/min for VOC liberation, followed by a 1 min dry purge (MCS bypass).
- Trap configuration: Vocarb 3000 sorbent, preheated to 245 °C, desorbed at 250 °C for 2 min, and baked at 260 °C for 8 min.
- GC conditions: Rtx-VRX column (75 m × 0.45 mm ID, 2.55 µm), initial oven at 35 °C (12 min), ramp to 60 °C at 5 °C/min, then to 220 °C at 17 °C/min.
- Carrier gas: helium at 9 mL/min.
- Detectors: µGold Tandem Photoionization Detector (PID) with makeup gas and HALL 2000 Electrolytic Conductivity Detector (ELCD).
Key Results and Discussion
Baseline separation was achieved for over 60 VOCs, including chloromethane, dichloroethanes, trichloroethylene, benzene, toluene, xylenes, and naphthalene. The method yielded detection limits in the low ppb range, with consistent retention times and detector responses, demonstrating suitability for trace-level monitoring in wastewater.
Benefits and Practical Applications
- Low detection limits support stringent regulatory requirements for water quality monitoring.
- Broad analyte coverage enables comprehensive environmental and industrial screening.
- High reproducibility and throughput facilitate routine QA/QC operations.
Future Trends and Potential Applications
Emerging developments include miniaturized purge-and-trap systems, real-time online monitoring, and coupling with mass spectrometry for enhanced selectivity. Integration with advanced data analytics and machine learning promises faster interpretation and proactive environmental management.
Conclusion
The described EPA Method 8021 configuration offers a robust, sensitive, and versatile platform for the analysis of volatile organics in aqueous matrices, meeting the needs of environmental laboratories and regulatory compliance programs.
Reference
Acknowledgement: µGold Tandem PID/HALL 2000 and Finnigan 9001 GC provided courtesy of Thermo Finnigan GC & GC/MS Division.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Volatile Organics US EPA Method 502.2 Rtx®-502.2
|Thermo Fisher Scientific|Applications
Volatile Organics US EPA Method 502.2 Rtx®-502.2 for more info A confirmational analysis can be found on www.restek.com/chromatograms Search for chromatogram number GC_EV00006 54/55 69 16 14 17 25 Rtx®-502.2 75m, 0.45mm ID, 2.55µm (cat.# 10986) 14 67 21 42/43…
Key words
butylbenzene, butylbenzenechloride, chloridexylene, xylenebenzene, benzenetert, tertelcd, elcdconfirmational, confirmationalpid, pidfluorobenzene, fluorobenzeneisopropyltoluene, isopropyltolueneinfo, infoallyl, allyldibromomethane, dibromomethanedichlorodifluoromethane, dichlorodifluoromethanebromobenzene
Optimizing the Analysis of Volatile Organic Compounds
2003|Restek|Guides
Technical Guide 1 Optimizing the Analysis of Volatile Organic Compounds Inside: EPA Method Definitions State GRO Methods Contract Laboratory Program (CLP) The Love Canal Scandal Purge and Trap Theory Sequences and Flow Paths of the Purge and Trap Unit Purge…
Key words
pack, packxylene, xylenertx, rtxtert, tertpid, pidbutylbenzene, butylbenzenepurge, purgeelcd, elcdeach, eachchloride, chloridetrap, trapbenzene, benzenedata, dataacetate, acetatevgc
Volatile Organics Confirmational Analysis EPA Method 502.2 Rtx®-1
|Thermo Fisher Scientific|Applications
Volatile Organics Confirmational Analysis EPA Method 502.2 Rtx®-1 1. dichlorodifluoromethane 2. chloromethane 3. vinyl chloride 4. bromomethane 5. chloroethane 6. trichlorofluoromethane 7. Freon® 113 8. 1,1-dichloroethene 9. allyl chloride 10. methylene chloride 11. methyl tert-butyl ether 12. trans-1,2-dichloroethene 13. 1,1-dichloroethane…
Key words
elcd, elcdfinnigan, finniganconfirmational, confirmationalpid, pidelectrolytic, electrolyticorganics, organicscourtesy, courtesyconductivity, conductivityvolatile, volatilethermo, thermoprovided, provideddetector, detectoranalysis
Volatile Organics EPA Method 8021A/502.2 - Rtx®-502.2
|Thermo Fisher Scientific|Applications
Volatile Organics EPA Method 8021A/502.2 Rtx®-502.2 Confirmational column to the Rtx®-VGC. Rtx®-502.2 49 51 75m, 0.45mm ID, 2.55µm (cat.# 10986) 30 9 38 46,47 60 50 57 14,13 35 39,40 10 6 63 58 48 32 16 64 66 2…
Key words
organics, organicsconcentrator, concentratorpress, pressconnector, connectortight, tightconnection, connectionvolatile, volatiledirect, directcolumns, columnscolumn, columnfrom