US EPA Method 625 Semivolatiles by GC-MS on the Supelco SLB™-5ms
Applications | 2008 | MerckInstrumentation
The analysis of semivolatile organic compounds in industrial and municipal wastewater is critical for environmental monitoring and regulatory compliance. US EPA Method 625 provides a standardized protocol to quantify a broad range of base-neutral and acid semivolatiles, ensuring reliable detection of priority pollutants.
This report demonstrates the application of EPA Method 625 on a Supelco SLB-5ms capillary GC column coupled with single-quadrupole mass spectrometry. Key objectives include:
The method employs liquid-liquid extraction into methylene chloride followed by splitless GC-MS analysis. Instrumental conditions:
The method achieved baseline resolution of all target compounds—including phenols, nitrophenols, chlorinated benzenes, polycyclic aromatic hydrocarbons, and phthalates—within a single run. Surrogate recoveries (e.g., 2-fluorobiphenyl, nitrobenzene-d5) and responses of internal standards (e.g., acenaphthene-d10) met EPA performance criteria, highlighting the method’s robustness and reproducibility.
This protocol supports comprehensive monitoring of wastewater discharges, facilitating compliance with environmental regulations. The SLB-5ms column’s selectivity, combined with MS detection, delivers high sensitivity for trace-level semivolatiles. Fast analysis times and consistent performance make it ideal for routine quality assurance in environmental laboratories.
Emerging developments may include:
The application of US EPA Method 625 on a Supelco SLB-5ms GC-MS system delivers reliable, sensitive quantitation of semivolatile pollutants in wastewater. Its demonstrated reproducibility and broad analyte coverage make it a valuable tool for environmental monitoring and regulatory compliance.
US EPA Method 625: Semivolatile Organic Compounds by GC/MS.
GC/MSD, GC columns, Consumables
IndustriesEnvironmental
ManufacturerMerck
Summary
Importance of the Topic
The analysis of semivolatile organic compounds in industrial and municipal wastewater is critical for environmental monitoring and regulatory compliance. US EPA Method 625 provides a standardized protocol to quantify a broad range of base-neutral and acid semivolatiles, ensuring reliable detection of priority pollutants.
Study Objectives and Overview
This report demonstrates the application of EPA Method 625 on a Supelco SLB-5ms capillary GC column coupled with single-quadrupole mass spectrometry. Key objectives include:
- Efficient separation of 79 semivolatile analytes and 6 internal standards
- Evaluation of method sensitivity and selectivity in wastewater matrices
- Verification of surrogate and internal standard performance
Methodology and Instrumentation
The method employs liquid-liquid extraction into methylene chloride followed by splitless GC-MS analysis. Instrumental conditions:
- Column: SLB-5ms, 30 m × 0.25 mm I.D., 0.25 µm film thickness
- Oven program: 40 °C (2 min), 22 °C/min to 240 °C, then 10 °C/min to 330 °C (5 min hold)
- Injection: 1 µL, pulsed at 15 psi until 0.10 min, splitless for 0.50 min
- Carrier gas: Helium at 1 mL/min for initial 10 min, then 1.5 mL/min
- MS conditions: Transfer line at 330 °C, scan range m/z 40–450
Main Results and Discussion
The method achieved baseline resolution of all target compounds—including phenols, nitrophenols, chlorinated benzenes, polycyclic aromatic hydrocarbons, and phthalates—within a single run. Surrogate recoveries (e.g., 2-fluorobiphenyl, nitrobenzene-d5) and responses of internal standards (e.g., acenaphthene-d10) met EPA performance criteria, highlighting the method’s robustness and reproducibility.
Benefits and Practical Applications
This protocol supports comprehensive monitoring of wastewater discharges, facilitating compliance with environmental regulations. The SLB-5ms column’s selectivity, combined with MS detection, delivers high sensitivity for trace-level semivolatiles. Fast analysis times and consistent performance make it ideal for routine quality assurance in environmental laboratories.
Future Trends and Possibilities
Emerging developments may include:
- Integration with high-resolution mass spectrometry for enhanced compound identification
- Automated sample preparation workflows to increase throughput
- Adoption of greener extraction solvents to reduce environmental impact
Conclusion
The application of US EPA Method 625 on a Supelco SLB-5ms GC-MS system delivers reliable, sensitive quantitation of semivolatile pollutants in wastewater. Its demonstrated reproducibility and broad analyte coverage make it a valuable tool for environmental monitoring and regulatory compliance.
References
US EPA Method 625: Semivolatile Organic Compounds by GC/MS.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Analysis of US EPA Method 8270D Semivolatiles Using SLB-5ms
2006|Merck|Applications
Application Report 391 Analysis of US EPA Method 8270D Semivolatiles Using SLB-5ms US EPA Method 8270D specifies a procedure for the determination of semivolatiles in solid wastes and ground waters. The suitability of the SLB-5ms for the separation of 72…
Key words
phthalate, phthalatebenzo, benzofluoranthene, fluorantheneanthracene, anthracenepyrene, pyrenebutylbenzyl, butylbenzylremainder, remaindernitrosodiphenylamine, nitrosodiphenylaminecarbazole, carbazolebenzidine, benzidinedibenzofuran, dibenzofuranazobenzene, azobenzenepropylamine, propylamineisophorone, isophoronenitroso
US EPA Method OLM04.2 SVOA (CLP Semivolatiles) by GC-MS on the Supelco SLB™-5ms
2008|Merck|Applications
Application Report 478 US EPA Method OLM04.2 SVOA (CLP Semivolatiles) by GC-MS on the Supelco SLB™-5ms Author: Katherine Stenerson Acquisition System: 5973 GC-MS Notebook Reference: 1569-084 The Contract Laboratory Program (CLP) is a nationwide network consisting of testing laboratories, contractors,…
Key words
phthalate, phthalatebenzo, benzofluoranthene, fluoranthenebenzyl, benzylanthracene, anthracenepyrene, pyrenebutyl, butylcaprolactam, caprolactamremainder, remaindernitrosodiphenylamine, nitrosodiphenylaminecarbazole, carbazoleazobenzene, azobenzenedibenzofuran, dibenzofuranacetophenone, acetophenonepropylamine
Analysis of US EPA Method 8270D Semivolatiles Using SLB-5ms
2005|Merck|Applications
Application Report 351 Author: Katherine Stenerson Acquisition System: 6890 GC / 5973 MSD Notebook Reference: 1509-098 Analysis of US EPA Method 8270D Semivolatiles Using SLB-5ms US EPA Method 8270D specifies a procedure for the determination of semivolatiles in solid wastes…
Key words
benzo, benzophthalate, phthalatefluoranthene, fluoranthenebenzidine, benzidineexcellent, excellentpentachlorophenol, pentachlorophenolanthracene, anthracenepyrene, pyrenebutylbenzyl, butylbenzylmillions, millionsremainder, remaindernitrosodiphenylamine, nitrosodiphenylaminecarbazole, carbazoledibenzofuran, dibenzofuranazobenzene
Shorter Analysis Time for Method 8270D on the SLB-5ms
2006|Merck|Applications
Application Report 398 Shorter Analysis Time for Method 8270D on the SLB-5ms Typical run times for US EPA Method 8270 range from 23 to 45 minutes. In this application, the high maximum operating temperature of the SLB-5ms was utilized to…
Key words
phthalate, phthalatebenzo, benzofluoranthene, fluorantheneanthracene, anthracenepyrene, pyrenebutylbenzyl, butylbenzylnitrosodiphenylamine, nitrosodiphenylaminecarbazole, carbazoleazobenzene, azobenzenedibenzofuran, dibenzofuranbenzidine, benzidinepropylamine, propylamineisophorone, isophoronenitroso, nitrosohexachlorocyclopentadiene