Nitrosamines - Analysis of nitrosamines to EPA 8270
Applications | 2011 | Agilent TechnologiesInstrumentation
Nitrosamines are a class of potent carcinogens that can form during industrial processes, in drinking water treatment, and in food packaging. Their presence at trace levels poses serious health risks, making accurate detection and quantification essential for environmental monitoring, regulatory compliance, and public safety.
This application note illustrates a rapid and reliable procedure to separate and identify nine nitrosamine compounds defined by EPA Method 8270. The goal is to achieve complete resolution in under 20 minutes using GC/MS on a specialized column.
The analysis utilizes gas chromatography coupled with mass spectrometry. Key parameters include:
The method achieves baseline separation of all nine nitrosamines—including N-nitrosodimethylamine through N-nitrosodiphenylamine—within a 20-minute runtime. Retention times and mass spectral data confirm identity, while reproducible peak areas demonstrate method precision. The FactorFour VF-200ms column’s selectivity contributes to sharp, well-defined peaks and minimal interferences.
Ongoing developments in column technology and high-resolution mass analyzers promise further reductions in analysis time and improved detection limits. Automation of sample preparation and implementation of portable GC/MS units may extend on-site monitoring capabilities in water treatment plants, chemical manufacturing, and environmental field studies.
This GC/MS method provides a fast, precise, and sensitive assay for nine EPA 8270 nitrosamines. Its robustness and compliance with regulatory standards make it a valuable tool for laboratories conducting environmental and public health analyses.
GC/MSD, GC columns, Consumables
IndustriesEnvironmental
ManufacturerAgilent Technologies
Summary
Analysis of Nitrosamines by GC/MS According to EPA 8270
Significance of the topic
Nitrosamines are a class of potent carcinogens that can form during industrial processes, in drinking water treatment, and in food packaging. Their presence at trace levels poses serious health risks, making accurate detection and quantification essential for environmental monitoring, regulatory compliance, and public safety.
Objectives and Study Overview
This application note illustrates a rapid and reliable procedure to separate and identify nine nitrosamine compounds defined by EPA Method 8270. The goal is to achieve complete resolution in under 20 minutes using GC/MS on a specialized column.
Methodology and Instrumentation
The analysis utilizes gas chromatography coupled with mass spectrometry. Key parameters include:
- Column: Agilent FactorFour VF-200ms, 0.25 mm × 30 m, film thickness 1.0 μm
- Temperature program: 45 °C initial (3 min), ramp 10 °C/min to 325 °C
- Carrier gas: Helium at ~1.0 mL/min, 60 kPa pressure program
- Injector: Split mode (1:100), injection volume 1 μL of methylene chloride solution (2000 μg/mL)
- Detector: Mass spectrometer operating in selected ion monitoring for enhanced sensitivity
Main Results and Discussion
The method achieves baseline separation of all nine nitrosamines—including N-nitrosodimethylamine through N-nitrosodiphenylamine—within a 20-minute runtime. Retention times and mass spectral data confirm identity, while reproducible peak areas demonstrate method precision. The FactorFour VF-200ms column’s selectivity contributes to sharp, well-defined peaks and minimal interferences.
Benefits and Practical Applications
- High throughput suitable for routine environmental and industrial screening
- Excellent resolution and reproducibility under EPA 8270 conditions
- Detection sensitivity aligned with stringent regulatory limits
- Efficient workflow using standard solvents and injection protocols
Future Trends and Potential Applications
Ongoing developments in column technology and high-resolution mass analyzers promise further reductions in analysis time and improved detection limits. Automation of sample preparation and implementation of portable GC/MS units may extend on-site monitoring capabilities in water treatment plants, chemical manufacturing, and environmental field studies.
Conclusion
This GC/MS method provides a fast, precise, and sensitive assay for nine EPA 8270 nitrosamines. Its robustness and compliance with regulatory standards make it a valuable tool for laboratories conducting environmental and public health analyses.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Nitrosamines - Analysis of EPA 8270 nitrosamines
2011|Agilent Technologies|Applications
Nitrosamines Analysis of EPA 8270 nitrosamines Application Note Environmental Authors Introduction Agilent Technologies, Inc. GC analysis of nine EPA 8270 nitrosamines on a 0.53 mm wide bore Agilent VF-5ms capillary column takes only 20 minutes. Conditions Technique : GC Column…
Key words
nitroso, nitrosonitoso, nitosomethylethylamine, methylethylaminepyrrolidine, pyrrolidinepiperidine, piperidinemorpholine, morpholinedimethylamine, dimethylaminebutylamine, butylaminediethylamine, diethylaminepropylamine, propylaminediphenylamine, diphenylaminenitrosamines, nitrosaminesprinted, printedinjector, injectorusa
Nitrosamines
2011|Agilent Technologies|Applications
Nitrosamines Application Note Environmental Authors Introduction Agilent Technologies, Inc. Analysis of nine nitrosamines by gas chromatography using an Agilent FactorFour VF-1301ms column in 22 minutes. Conditions Technique : GC-capillary Column : Agilent FactorFour VF-1301ms, 0.25 mm x 30 m fused…
Key words
nitroso, nitrosonitrosamines, nitrosaminesmethylethylamine, methylethylaminepyrrolidine, pyrrolidinefactorfour, factorfourpiperidine, piperidinemorpholine, morpholinedimethylamine, dimethylaminebutylamine, butylaminediethylamine, diethylaminepropylamine, propylaminediphenylamine, diphenylaminenine, ninecourtesy, courtesygas
Nitrosamines
2011|Agilent Technologies|Applications
Nitrosamines Application Note Environmental Authors Introduction Agilent Technologies, Inc. GC analysis of nitrosamines according to EPA 8270 uses the stabilized 50% phenyl PDMS of an Agilent VF-17ms column. Conditions Technique : GC Column : Agilent VF-17ms, 0.53 mm x 30…
Key words
nitroso, nitrosonitoso, nitosomethylethylamine, methylethylaminepyrrolidine, pyrrolidinepiperidine, piperidinemorpholine, morpholinedimethylamine, dimethylaminebutylamine, butylaminediethylamine, diethylaminepropylamine, propylaminediphenylamine, diphenylaminenitrosamines, nitrosaminescourtesy, courtesyprinted, printedinjector
Base neutrals - Base neutrals to EPA 8270
2011|Agilent Technologies|Applications
Base neutrals Base neutrals to EPA 8270 Application Note Environmental Authors Introduction Agilent Technologies, Inc. Using GC/MS, an Agilent FactorFour VF-200ms column separates 13 base neutrals according to EPA8270 in 20 minutes. Conditions Technique : GC Column : Agilent FactorFour…
Key words
neutrals, neutralscourtesy, courtesybase, baseprinted, printedinjector, injectorusa, usaauthors, authorsprogram, programenvironmental, environmentalsize, sizetechnique, techniquecarrier, carrieridentification, identificationpressure, pressuresolvent