Nitrosamines
Applications | 2011 | Agilent TechnologiesInstrumentation
Nitrosamines are potent carcinogenic contaminants that can form during various chemical and industrial processes. Accurate and rapid detection of these compounds in environmental and pharmaceutical samples is crucial for regulatory compliance and public health protection.
This application note presents a method for the simultaneous analysis of nine nitrosamines using gas chromatography. The primary goal was to achieve baseline separation and quantification within a concise runtime of 22 minutes.
The method successfully separated nine nitrosamines with clear peak resolution. Analytes included N-nitrosodimethylamine, N-nitrosodiethylamine, and other N-nitroso derivatives ranging from small aliphatic amines to diphenylamine. The optimized parameters provided consistent retention times and reproducible detector responses, demonstrating the robustness of the VF-1301ms column for volatile nitrosamine analysis.
Ongoing developments may include coupling with mass spectrometry for enhanced sensitivity and selectivity. Miniaturized and automated gas chromatography systems could further streamline nitrosamine testing in field and on-site applications.
This method offers a rapid, reliable approach for nitrosamine analysis in various matrices. The efficient separation achieved on the Agilent VF-1301ms column makes it a valuable tool for laboratories requiring timely and accurate contaminant screening.
No references were provided in the original document.
GC, GC columns, Consumables
IndustriesEnvironmental
ManufacturerAgilent Technologies
Summary
Importance of Nitrosamine Analysis
Nitrosamines are potent carcinogenic contaminants that can form during various chemical and industrial processes. Accurate and rapid detection of these compounds in environmental and pharmaceutical samples is crucial for regulatory compliance and public health protection.
Objectives and Study Overview
This application note presents a method for the simultaneous analysis of nine nitrosamines using gas chromatography. The primary goal was to achieve baseline separation and quantification within a concise runtime of 22 minutes.
Methodology and Instrumentation
- Technique: Gas chromatography with capillary column
- Column: Agilent FactorFour VF-1301ms, 0.25 mm × 30 m, 0.25 µm film
- Temperature program: 45 °C (3 min) to 280 °C at 10 °C/min
- Carrier gas: Helium at 60 kPa
- Injection: Split mode (1:100), 1 µL sample volume
- Detector: Flame ionization detector
Main Results and Discussion
The method successfully separated nine nitrosamines with clear peak resolution. Analytes included N-nitrosodimethylamine, N-nitrosodiethylamine, and other N-nitroso derivatives ranging from small aliphatic amines to diphenylamine. The optimized parameters provided consistent retention times and reproducible detector responses, demonstrating the robustness of the VF-1301ms column for volatile nitrosamine analysis.
Benefits and Practical Applications
- Fast analysis time suitable for high-throughput laboratories
- High resolution ensures reliable identification and quantification
- Applicable to environmental monitoring and quality control in pharmaceutical production
Future Trends and Applications
Ongoing developments may include coupling with mass spectrometry for enhanced sensitivity and selectivity. Miniaturized and automated gas chromatography systems could further streamline nitrosamine testing in field and on-site applications.
Conclusion
This method offers a rapid, reliable approach for nitrosamine analysis in various matrices. The efficient separation achieved on the Agilent VF-1301ms column makes it a valuable tool for laboratories requiring timely and accurate contaminant screening.
References
No references were provided in the original document.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Nitrosamines - Analysis of nitrosamines to EPA 8270
2011|Agilent Technologies|Applications
Nitrosamines Analysis of nitrosamines to EPA 8270 Application Note Environmental Authors Introduction Agilent Technologies, Inc. Using GC/MS, an Agilent FactorFour VF-200ms column separates nine nitrosamines according to EPA 8270 in less than 20 minutes. Conditions Technique : GC Column :…
Key words
nitroso, nitrosomethylethylamine, methylethylaminepyrrolidine, pyrrolidinepiperidine, piperidinemorpholine, morpholinedimethylamine, dimethylaminebutylamine, butylaminediethylamine, diethylaminepropylamine, propylaminediphenylamine, diphenylaminenitrosamines, nitrosaminescourtesy, courtesyprinted, printedinjector, injectorusa
Nitrosamines
2011|Agilent Technologies|Applications
Nitrosamines Application Note Environmental Authors Introduction Agilent Technologies, Inc. Separation of nine nitrosamines using Agilent VF-1701ms in 20 minutes. Conditions Technique : GC-capillary Column : Agilent FactorFourVF-1701ms, 0.25 mm x 30 m fused silica (df= 0.25 μm) (Part no. CP9151)…
Key words
nitroso, nitrosomethylethylamine, methylethylaminepyrrolidine, pyrrolidinepiperidine, piperidinemorpholine, morpholinedimethylamine, dimethylaminebutylamine, butylaminediethylamine, diethylaminepropylamine, propylaminediphenylamine, diphenylaminenitrosamines, nitrosaminescourtesy, courtesyprinted, printedinjector, injectorusa
Nitrosamines
2011|Agilent Technologies|Applications
Nitrosamines Application Note Environmental Authors Introduction Agilent Technologies, Inc. GC separation of 13 basic aromatic compounds uses the stabilized 50% phenyl PDMS phase of an Agilent VF-17ms column. Conditions Technique : GC Column : Agilent VF-17ms, 0.25 mm x 30…
Key words
nitroso, nitrosonitoso, nitosomethylethylamine, methylethylaminepyrrolidine, pyrrolidinepiperidine, piperidinemorpholine, morpholinedimethylamine, dimethylaminebutylamine, butylaminediethylamine, diethylaminepropylamine, propylaminediphenylamine, diphenylaminenitrosamines, nitrosaminescourtesy, courtesyprinted, printedinjector
Nitrosamines - Analysis of EPA 8270 nitrosamines
2011|Agilent Technologies|Applications
Nitrosamines Analysis of EPA 8270 nitrosamines Application Note Environmental Authors Introduction Agilent Technologies, Inc. GC analysis of nine EPA 8270 nitrosamines on a 0.53 mm wide bore Agilent VF-5ms capillary column takes only 20 minutes. Conditions Technique : GC Column…
Key words
nitroso, nitrosonitoso, nitosomethylethylamine, methylethylaminepyrrolidine, pyrrolidinepiperidine, piperidinemorpholine, morpholinedimethylamine, dimethylaminebutylamine, butylaminediethylamine, diethylaminepropylamine, propylaminediphenylamine, diphenylaminenitrosamines, nitrosaminesprinted, printedinjector, injectorusa