Base neutrals
Applications | 2011 | Agilent TechnologiesInstrumentation
Analysis of base neutrals is critical in environmental monitoring to assess contamination by semi-volatile organic compounds. These analytes, often by-products of industrial processes, impact water and soil quality. Fast, reliable screening methods enable regulatory compliance and support quality control in laboratories.
This application note describes a gas chromatographic method for the separation and quantification of 14 base neutral compounds. Using an Agilent VF-200ms column, the method achieves baseline resolution within 28 minutes, illustrating its suitability for routine environmental analysis.
Technique and instrumentation details:
The optimized conditions delivered clear separation of 14 target compounds, including nitrosamines, phthalates, halogenated ethers, and phenyl ethers. Retention times were reproducible, and peak shapes were sharp, demonstrating the column's high selectivity for a diverse set of base neutrals. The FID provided stable response factors across this compound class.
This rapid GC-FID protocol offers several practical advantages:
Future developments may include coupling this separation with mass spectrometric detection for enhanced sensitivity and specificity. Advances in column technology and programming flexibility could further reduce run times. Integration into automated platforms will support high-throughput environmental screening and real-time monitoring.
The described GC-FID method on an Agilent VF-200ms column delivers fast, reliable separation of 14 base neutrals, making it a valuable tool for environmental analysis and routine quality control. Its simplicity and performance facilitate adoption in diverse laboratory settings.
GC, GC columns, Consumables
IndustriesEnvironmental
ManufacturerAgilent Technologies
Summary
Význam tématu
Analysis of base neutrals is critical in environmental monitoring to assess contamination by semi-volatile organic compounds. These analytes, often by-products of industrial processes, impact water and soil quality. Fast, reliable screening methods enable regulatory compliance and support quality control in laboratories.
Cíle a přehled studie / článku
This application note describes a gas chromatographic method for the separation and quantification of 14 base neutral compounds. Using an Agilent VF-200ms column, the method achieves baseline resolution within 28 minutes, illustrating its suitability for routine environmental analysis.
Použitá metodika a instrumentace
Technique and instrumentation details:
- Gas chromatography with flame ionization detection (GC-FID)
- Column: Agilent FactorFour VF-200ms, 0.25 mm × 30 m, film thickness 0.25 µm
- Temperature program: initial 45 °C, ramp 10 °C/min to 325 °C
- Carrier gas: helium at ~1.0 mL/min, constant pressure 60 kPa
- Injector: split mode, split ratio 1:100
- Sample volume: 1 µL in methylene chloride (2000 µg/mL)
Hlavní výsledky a diskuse
The optimized conditions delivered clear separation of 14 target compounds, including nitrosamines, phthalates, halogenated ethers, and phenyl ethers. Retention times were reproducible, and peak shapes were sharp, demonstrating the column's high selectivity for a diverse set of base neutrals. The FID provided stable response factors across this compound class.
Přínosy a praktické využití metody
This rapid GC-FID protocol offers several practical advantages:
- High throughput with sub-half-hour analysis time
- Robust resolution of structurally similar base neutrals
- Ease of implementation in routine environmental or QA/QC labs
- Cost‐effective instrumentation and consumables
Budoucí trendy a možnosti využití
Future developments may include coupling this separation with mass spectrometric detection for enhanced sensitivity and specificity. Advances in column technology and programming flexibility could further reduce run times. Integration into automated platforms will support high-throughput environmental screening and real-time monitoring.
Závěr
The described GC-FID method on an Agilent VF-200ms column delivers fast, reliable separation of 14 base neutrals, making it a valuable tool for environmental analysis and routine quality control. Its simplicity and performance facilitate adoption in diverse laboratory settings.
Reference
- Agilent Technologies, Inc. Application Note A02200, "Base neutrals GC analysis," October 2011.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Base neutrals
2011|Agilent Technologies|Applications
Base neutrals Application Note Environmental Authors Introduction Agilent Technologies, Inc. Agilent VF-1701ms columns separate 14 base neutrals in 37 minutes. Conditions Technique : GC-capillary Column : Agilent FactorFourVF-1701ms, 0.25 mm x 30 m fused silica (df= 0.25 μm) (Part no.…
Key words
neutrals, neutralscourtesy, courtesybase, baseprinted, printedinjector, injectorusa, usaauthors, authorsenvironmental, environmentalsize, sizetechnique, techniquecarrier, carrieridentification, identificationdetector, detectornote, notepeak
Base neutrals
2011|Agilent Technologies|Applications
Base neutrals Application Note Environmental Authors Introduction Agilent Technologies, Inc. Analysis of 14 base neutrals by gas chromatography using an Agilent FactorFour VF-1301ms column in less than 40 minutes. Conditions Technique : GC-capillary Column : Agilent FactorFour VF-1301ms, 0.25 mm…
Key words
neutrals, neutralscourtesy, courtesybase, baseprinted, printedinjector, injectorusa, usaauthors, authorsenvironmental, environmentaltechnique, techniquecarrier, carrieridentification, identificationdetector, detectornote, notepeak, peaktemperature
Base neutrals
2011|Agilent Technologies|Applications
Base neutrals Application Note Environmental Authors Introduction Agilent Technologies, Inc. The Agilent VF-17ms GC column separates 14 base neutrals in 28 minutes. Conditions Technique : GC Column : Agilent VF-17ms, 0.25 mm x 30 m fused silica (df = 0.25…
Key words
neutrals, neutralsbase, baseprinted, printedinjector, injectorusa, usaauthors, authorsenvironmental, environmentalsize, sizetechnique, techniquecarrier, carrieridentification, identificationdetector, detectornote, notepeak, peaktemperature
EPA 8270 Semi-volatile Analysis on an Agilent J&W FactorFour VF-5ms GC Column
2010|Agilent Technologies|Applications
EPA 8270 Semi-volatile Analysis on an Agilent J&W FactorFour VF-5ms GC Column Application Note Author Introduction Laura Provoost Agilent Technologies, Inc. U.S. Environmental Protection Agency (EPA) method 8270D, Semivolatile Organic Compounds By Gas Chromatography/Mass Spectrometry (GC/MS), is a challenging method.…
Key words
fluoranthene, fluoranthenebenzo, benzominutes, minuteschrysene, chryseneanthracene, anthracenebenz, benzpyrene, pyrenephthalate, phthalatebutyl, butylprovoost, provoostoctylphthalate, octylphthalatelaura, lauradiethylphthalate, diethylphthalatedimethylphthalate, dimethylphthalatenitrosodi