PAHs and phenols
Applications | 2011 | Agilent TechnologiesInstrumentation
Importance of the topic
The accurate separation and quantification of polyaromatic hydrocarbons (PAHs) and phenolic compounds is critical for environmental monitoring, industrial quality control, and public health assessments. These compounds, often arising from combustion processes and industrial effluents, pose significant toxicological risks. Fast and reliable analytical methods enable routine screening of complex matrices, ensuring regulatory compliance and timely risk management.
Objectives and study overview
This application study demonstrates the rapid separation of 19 PAHs and phenols using gas chromatography on an Agilent CP-Wax 52 CB capillary column. The goal is to achieve baseline resolution within a 22-minute run time, facilitating high sample throughput for environmental and industrial laboratories.
Methodology and instrumentation
Main results and discussion
The optimized temperature gradient ensured clear separation of all target analytes in under 22 minutes. Peak identification covered 19 compounds, including simple PAHs (naphthalene, fluorene, acenaphthene), alkylated homologues (methyl- and dimethylnaphthalenes), heterocycles (quinoline, isoquinoline), and cresol isomers. The method achieved sharp, symmetric peaks with adequate resolution between closely eluting species, demonstrating robust reproducibility.
Benefits and practical applications of the method
Future trends and potential applications
Advances in detector sensitivity and automation will further reduce analysis time and detection limits. Coupling with mass spectrometry would enable structural confirmation and trace-level quantitation. Integration with online sampling systems could support real-time monitoring of emissions and effluents in manufacturing and combustion facilities.
Conclusion
This application note demonstrates a fast, reliable GC-FID method for separating 19 PAHs and phenols using an Agilent CP-Wax 52 CB column. Its combination of speed, resolution, and ease of use makes it ideal for environmental laboratories and industrial QA/QC settings, ensuring accurate assessment of complex samples without extensive method development.
GC, GC columns, Consumables
IndustriesEnvironmental
ManufacturerAgilent Technologies
Summary
PAHs and Phenols Analysis Using GC with CP-Wax 52 CB Column
Importance of the topic
The accurate separation and quantification of polyaromatic hydrocarbons (PAHs) and phenolic compounds is critical for environmental monitoring, industrial quality control, and public health assessments. These compounds, often arising from combustion processes and industrial effluents, pose significant toxicological risks. Fast and reliable analytical methods enable routine screening of complex matrices, ensuring regulatory compliance and timely risk management.
Objectives and study overview
This application study demonstrates the rapid separation of 19 PAHs and phenols using gas chromatography on an Agilent CP-Wax 52 CB capillary column. The goal is to achieve baseline resolution within a 22-minute run time, facilitating high sample throughput for environmental and industrial laboratories.
Methodology and instrumentation
- Technique: Gas chromatography with capillary column.
- Column: Agilent CP-Wax 52 CB, 0.25 mm × 25 m, df = 0.2 μm (Part no. CP7713).
- Temperature Program: Start at 70 °C (4 min), ramp to 140 °C at 7 °C/min, then to 230 °C at 4 °C/min, hold for 15 min.
- Carrier Gas: Nitrogen at 85 kPa (0.85 bar, 12 psi).
- Injection: Split mode, split ratio 1:100, injection volume 0.2 μL.
- Detector: Flame ionization detector (FID).
Main results and discussion
The optimized temperature gradient ensured clear separation of all target analytes in under 22 minutes. Peak identification covered 19 compounds, including simple PAHs (naphthalene, fluorene, acenaphthene), alkylated homologues (methyl- and dimethylnaphthalenes), heterocycles (quinoline, isoquinoline), and cresol isomers. The method achieved sharp, symmetric peaks with adequate resolution between closely eluting species, demonstrating robust reproducibility.
Benefits and practical applications of the method
- High throughput: Complete analysis in less than 25 minutes allows screening of large sample batches.
- Comprehensive coverage: Simultaneous detection of both PAHs and phenolic compounds in a single run.
- Operational simplicity: Standard GC-FID setup with a widely available CP-Wax 52 CB column.
- Regulatory relevance: Suitable for routine environmental monitoring and industrial process verification.
Future trends and potential applications
Advances in detector sensitivity and automation will further reduce analysis time and detection limits. Coupling with mass spectrometry would enable structural confirmation and trace-level quantitation. Integration with online sampling systems could support real-time monitoring of emissions and effluents in manufacturing and combustion facilities.
Conclusion
This application note demonstrates a fast, reliable GC-FID method for separating 19 PAHs and phenols using an Agilent CP-Wax 52 CB column. Its combination of speed, resolution, and ease of use makes it ideal for environmental laboratories and industrial QA/QC settings, ensuring accurate assessment of complex samples without extensive method development.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Phenols
2011|Agilent Technologies|Applications
Phenols Application Note Materials Testing & Research Authors Introduction Agilent Technologies, Inc. Gas chromatography using an Agilent CP-Sil 43 CB column separates 14 phenols in about 50 minutes. Conditions Peak identification Technique : GC-capillary Column : Agilent CP-Sil 43 CB,…
Key words
phenols, phenolsprinted, printedinjector, injectorresearch, researchusa, usatesting, testingauthors, authorstechnique, techniquecarrier, carrieridentification, identificationmaterials, materialsdetector, detectornote, notepeak, peaktemperature
Phenols
2011|Agilent Technologies|Applications
Phenols Application Note Environmental Authors Introduction Agilent Technologies, Inc. GC separation of 12 phenols using an Agilent CP-Sil 19 CB column with FID is achieved in 15 minutes. Conditions Technique : GC Column : Agilent CP-Sil 19 CB, 0.32 mm…
Key words
phenols, phenolscourtesy, courtesyprinted, printedinjector, injectorusa, usaauthors, authorsenvironmental, environmentalsize, sizetechnique, techniquesample, samplecarrier, carrieridentification, identificationsolvent, solventdetector, detectornote
Analysis of Free Volatile Phenols in Smoke-Impacted Wines by SPME
2021|Agilent Technologies|Applications
Application Note Food Testing and Agriculture Analysis of Free Volatile Phenols in Smoke-Impacted Wines by SPME Authors Jessica Westland and Vanessa Abercrombie Agilent Technologies, Inc. Abstract Ever since the 2003 wildfires in Australia and British Columbia, smoke impact has been…
Key words
smoke, smokecresol, cresolwine, wineguaiacol, guaiacolgrapes, grapesspme, spmephenols, phenolsnoir, noirpinot, pinotfranzia, franziaimpact, impactloq, loqvolatile, volatilefree, freerelative
Phenols and cresols - Separation of isomers and aromatic alcohols on a chiral capillary column
2011|Agilent Technologies|Applications
Phenols and cresols Separation of isomers and aromatic alcohols on a chiral capillary column Application Note Environmental Authors Introduction Agilent Technologies, Inc. The Agilent CP-Chirasil-Dex CB column is not only suited for the separation of optical isomers, but has also…
Key words
cresols, cresolschirasil, chirasildex, dexphenols, phenolschiral, chiralcolumn, columnalcohols, alcoholscourtesy, courtesyseparation, separationisomers, isomersaromatic, aromaticsuited, suitedprinted, printedinjector, injectorusa