Analysis of Impurities in o-xylene using Agilent J&W FactorFour VF-WAXms GC Columns
Applications | 2010 | Agilent TechnologiesInstrumentation
GC, GC columns, Consumables
IndustriesEnergy & Chemicals
ManufacturerAgilent Technologies
Key wordsxylene, waxms, jacobse, helena, factorfour, impurities, columns, author, fid, using, analysis, agilent, note, min, conditions, application
Similar PDF
Analysis of Aromatics using Agilent J&W FactorFour VF-WAXms GC Columns
2010|Agilent Technologies|Applications
Analysis of Aromatics using Agilent J&W FactorFour VF-WAXms GC Columns Application Note Author Helena Jacobse Agilent Technologies, Inc. Conditions Technique: Column: Temperature: Carrier Gas: Injector: Detector: Sample Size: Sample: GC-FID VF-WAXms 60 m x 0.25 mm df = 0.25 µm…
Key words
waxms, waxmsaromatics, aromaticsjacobse, jacobsehelena, helenafactorfour, factorfourcolumns, columnsfid, fidauthor, authorusing, usinganalysis, analysisagilent, agilentnote, notemin, minconditions, conditionsapplication
Fast Fingerprint Analysis of Perfume using Agilent J&W FactorFour VF-WAXms High Efficiency GC Columns
2010|Agilent Technologies|Applications
Fast Fingerprint Analysis of Perfume using Agilent J&W FactorFour VF-WAXms High Efficiency GC Columns Application Note Author Introduction Helena Jacobse Agilent Technologies, Inc. The VF-WAXms column shows excellent selectivity for the many volatiles present in perfumes. Use of the 0.15…
Key words
waxms, waxmsjacobse, jacobsehelena, helenafactorfour, factorfourperfume, perfumefingerprint, fingerprintvolatiles, volatilesmin, minauthor, authorfid, fidselectivity, selectivityefficiency, efficiencypresent, presentshows, showsexcellent
Analysis of Lavandin using Agilent J&W FactorFour VF-WAXms GC Columns
2010|Agilent Technologies|Applications
Analysis of Lavandin using Agilent J&W FactorFour VF-WAXms GC Columns Application Note Author Helena Jacobse Agilent Technologies, Inc. Conditions Technique: Column: Temperature: Carrier Gas: GC-FID VF-WAXms 30 m x 0.25 mm df = 0.25 µm (part number CP9205) 100 °C…
Key words
lavandin, lavandinwaxms, waxmsjacobse, jacobsehelena, helenafactorfour, factorfourcolumns, columnsfid, fidauthor, authorusing, usinganalysis, analysisagilent, agilentnote, notemin, minconditions, conditionsapplication
Stabilwax®-MS Columns
2013|Agilent Technologies|Applications
Stabilwax®-MS Columns Thermally Stable, High Polarity GC Columns for Flavor, Food, Fragrance, Industrial Chemical, and Solvent Analyses What’s Inside… New Stabilwax®-MS columns...................p. 2–3 Applications Fragrances........................................................... p. 4 Flavors and foods..........................................p. 5–6 Industrial chemicals.....................................p. 7–8 Cleaning solvents.............................................. p. 9 MS accessories...........................................p.…
Key words
stabilwax, stabilwaxleak, leakacetate, acetateglycol, glycolkit, kitrestek, restekcleaning, cleaningmin, minallergen, allergenyour, yourbleed, bleeddetector, detectorpeaks, peaksxylene, xyleneether