Fast Fingerprint Analysis of Perfume using Agilent J&W FactorFour VF-WAXms High Efficiency GC Columns
Applications | 2010 | Agilent TechnologiesInstrumentation
GC, GC columns, Consumables
IndustriesOthers
ManufacturerAgilent Technologies
Key wordswaxms, jacobse, helena, factorfour, perfume, fingerprint, volatiles, min, author, fid, selectivity, efficiency, present, shows, excellent, many, fast, columns, agilent, note, conditions, application, high, column, introduction, using, analysis
Similar PDF
Analysis of Ylang Oil using Agilent J&W FactorFour VF-WAXms GC Columns
2010|Agilent Technologies|Applications
Analysis of Ylang Oil using Agilent J&W FactorFour VF-WAXms GC Columns Application Note Author Helena Jacobse Agilent Technologies, Inc. Conditions Technique: Sample: Sample Size: Column: Carrier Gas: Injector: Temperature: Detection: GC-FID Ylang oil, 0.1 % (acetone)…
Key words
ylang, ylangwaxms, waxmsjacobse, jacobsehelena, helenafactorfour, factorfouroil, oilcolumns, columnsauthor, authorfid, fidusing, usinganalysis, analysisagilent, agilentnote, notemin, minconditions
Analysis of Fragrance and Allergens using an Agilent J&W FactorFour VF-WAXms GC Column
2010|Agilent Technologies|Applications
Analysis of Fragrance and Allergens using an Agilent J&W FactorFour VF-WAXms GC Column Application Note Author Introduction John Oostdijk Agilent Technologies, Inc. Allergic reactions to perfumes and the individual components responsible for these reactions have been studied since the late…
Key words
benzyl, benzyleugenol, eugenolmethyl, methylalcohol, alcoholfarnesol, farnesolcinnamyl, cinnamylcinnamic, cinnamicwaxms, waxmsamyl, amylaldehyde, aldehydeoctin, octinisomer, isomercarbonate, carbonateanisic, anisiccoumarine
Analysis of Lavandin using Agilent J&W FactorFour VF-WAXms GC Columns
2010|Agilent Technologies|Applications
Analysis of Lavandin using Agilent J&W FactorFour VF-WAXms GC Columns Application Note Author Helena Jacobse Agilent Technologies, Inc. Conditions Technique: Column: Temperature: Carrier Gas: GC-FID VF-WAXms 30 m x 0.25 mm df = 0.25 µm (part number CP9205) 100 °C…
Key words
lavandin, lavandinwaxms, waxmsjacobse, jacobsehelena, helenafactorfour, factorfourcolumns, columnsfid, fidauthor, authorusing, usinganalysis, analysisagilent, agilentnote, notemin, minconditions, conditionsapplication
Analysis of Aromatics using Agilent J&W FactorFour VF-WAXms GC Columns
2010|Agilent Technologies|Applications
Analysis of Aromatics using Agilent J&W FactorFour VF-WAXms GC Columns Application Note Author Helena Jacobse Agilent Technologies, Inc. Conditions Technique: Column: Temperature: Carrier Gas: Injector: Detector: Sample Size: Sample: GC-FID VF-WAXms 60 m x 0.25 mm df = 0.25 µm…
Key words
waxms, waxmsaromatics, aromaticsjacobse, jacobsehelena, helenafactorfour, factorfourcolumns, columnsfid, fidauthor, authorusing, usinganalysis, analysisagilent, agilentnote, notemin, minconditions, conditionsapplication