Analysis of Aromatics using Agilent J&W FactorFour VF-WAXms GC Columns
Applications | 2010 | Agilent TechnologiesInstrumentation
GC, GC columns, Consumables
IndustriesEnergy & Chemicals
ManufacturerAgilent Technologies
Key wordswaxms, aromatics, jacobse, helena, factorfour, columns, author, fid, using, analysis, agilent, note, min, conditions, application
Similar PDF
Analysis of Impurities in o-xylene using Agilent J&W FactorFour VF-WAXms GC Columns
2010|Agilent Technologies|Applications
Analysis of Impurities in o-xylene using Agilent J&W FactorFour VF-WAXms GC Columns Application Note Injector: Detector: Sample Size: Sample: 250 °C, split 75 mL/min 275 °C, FID 0.1 µL o-xylene oxylene Temperature: Carrier Gas: GC-FID VF-WAXms 60 m x 0.25…
Key words
xylene, xylenewaxms, waxmsjacobse, jacobsehelena, helenaimpurities, impuritiesfactorfour, factorfourcolumns, columnsauthor, authorfid, fidusing, usinganalysis, analysisagilent, agilentnote, notemin, minconditions
Analysis of Ylang Oil using Agilent J&W FactorFour VF-WAXms GC Columns
2010|Agilent Technologies|Applications
Analysis of Ylang Oil using Agilent J&W FactorFour VF-WAXms GC Columns Application Note Author Helena Jacobse Agilent Technologies, Inc. Conditions Technique: Sample: Sample Size: Column: Carrier Gas: Injector: Temperature: Detection: GC-FID Ylang oil, 0.1 % (acetone)…
Key words
ylang, ylangwaxms, waxmsjacobse, jacobsehelena, helenafactorfour, factorfouroil, oilcolumns, columnsauthor, authorfid, fidusing, usinganalysis, analysisagilent, agilentnote, notemin, minconditions
Analysis of Lavandin using Agilent J&W FactorFour VF-WAXms GC Columns
2010|Agilent Technologies|Applications
Analysis of Lavandin using Agilent J&W FactorFour VF-WAXms GC Columns Application Note Author Helena Jacobse Agilent Technologies, Inc. Conditions Technique: Column: Temperature: Carrier Gas: GC-FID VF-WAXms 30 m x 0.25 mm df = 0.25 µm (part number CP9205) 100 °C…
Key words
lavandin, lavandinwaxms, waxmsjacobse, jacobsehelena, helenafactorfour, factorfourcolumns, columnsauthor, authorfid, fidusing, usinganalysis, analysisagilent, agilentnote, notemin, minconditions, conditionsapplication
Fast Fingerprint Analysis of Perfume using Agilent J&W FactorFour VF-WAXms High Efficiency GC Columns
2010|Agilent Technologies|Applications
Fast Fingerprint Analysis of Perfume using Agilent J&W FactorFour VF-WAXms High Efficiency GC Columns Application Note Author Introduction Helena Jacobse Agilent Technologies, Inc. The VF-WAXms column shows excellent selectivity for the many volatiles present in perfumes. Use of the 0.15…
Key words
waxms, waxmsjacobse, jacobsehelena, helenafactorfour, factorfourperfume, perfumefingerprint, fingerprintvolatiles, volatilesmin, minauthor, authorfid, fidselectivity, selectivityefficiency, efficiencypresent, presentshows, showsexcellent