GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

US EPA Method 8081 Chlorinated Pesticides on Equity-5

Applications | 2003 | MerckInstrumentation
GC, GC columns, Consumables
Industries
Environmental
Manufacturer
Merck

Summary

Significance of the Topic


The persistence and toxicity of chlorinated pesticides have driven stringent regulations and demand for accurate analysis methods. Gas chromatography with electron capture detection (GC/ECD) remains a cornerstone technique for monitoring these compounds in environmental and regulatory contexts.

Objectives and Study Overview


This application report evaluates the performance of a 5% phenyl methylpolysiloxane capillary column (Equity-5) under US EPA Method 8081 conditions. Twenty target pesticides and two surrogate standards were analyzed to assess chromatographic separation, peak quality, and system stability.

Methodology and Used Instrumentation


The analysis was conducted on a GC1777 system equipped with an ECD at 310°C. Key parameters:
  • Column: Equity-5, 30 m × 0.25 mm ID, 0.25 µm film thickness
  • Oven program: 100°C (2 min) to 160°C at 15°C/min, then to 300°C at 5°C/min (hold 10 min)
  • Injector: 225°C, splitless injection (2 µL, 0.5 min)
  • Carrier gas: Helium, constant flow at 30 cm/s (100°C reference)
  • Liner: 4 mm ID double taper
  • Sample: 50 ppb each of a 22-component chlorinated pesticide standard

Main Results and Discussion


The Equity-5 column provided excellent peak shapes and high resolution for all 20 pesticides and two surrogates within a 30-minute run. Baseline stability and low bleed were maintained throughout the temperature gradient, supporting reliable quantitation.

Benefits and Practical Applications


  • Enhanced separation efficiency for regulated chlorinated pesticides
  • Robust baseline and low column bleed suitable for trace-level detection
  • Compliance with US EPA Method 8081 requirements
  • Applicability to environmental monitoring, QA/QC, and contract laboratories

Future Trends and Potential Applications


Emerging column technologies and detection methods, such as GC–MS coupling and microfluidic GC, offer prospects for greater sensitivity, faster analysis, and reduced solvent usage. Automation and high-throughput workflows will further expand capabilities in monitoring legacy and emerging pollutants.

Conclusion


The Equity-5 capillary column demonstrates reliable performance under US EPA Method 8081 conditions for chlorinated pesticide analysis. Its combination of peak resolution, baseline stability, and low bleed makes it an effective tool for regulatory and environmental laboratories.

References


No specific literature references were listed in the original document.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
US EPA Method 8081 Chlorinated Pesticides on Equity-1701
Application Report 27 Author: J. Walbridge/K. Kiefer US EPA Method 8081 Chlorinated Pesticides on Equity-1701 Raw Data File Name: 1701\211BC015.D US EPA method 8081 describes the GC/ECD analysis of organochlorine pesticides and requires the use of a primary and confirmation…
Key words
bhc, bhcendrin, endrinendosulfan, endosulfanchlordane, chlordaneheptachlor, heptachlorids, idsmethoxychlor, methoxychloraldehyde, aldehydeepoxide, epoxidedieldrin, dieldrinaldrin, aldrinketone, ketonesulfate, sulfatewords, wordskey
Equity™ Capillary GC Columns
Equity™ Capillary GC Columns
2003|Merck|Brochures and specifications
SUPELCO EQUITY CAPILLARY GC COLUMNS Equity™ Capillary GC Columns The performance you demand... the service you deserve... from the company you trust. Updated with: ● NEW Equity-1701 columns ● New Applications 1 sigma-aldrich.com/supelco SUPELCO EQUITY CAPILLARY GC COLUMNS The performance…
Key words
equity, equitysupelco, supelcocapillary, capillarymin, mincolumns, columnscapseal, capsealexcellent, excellentbullet, bulletresponse, responsebleed, bleedshapes, shapesacetate, acetatemethyl, methylendosulfan, endosulfansupeltex
US EPA Method 608, 8081, OLM04.2 Organochlorine Pesticides on the SPB-608
Application Report 388 Author: Katherine Stenerson Acquisition System: 6249 Notebook Reference: 1569-016 US EPA Method 608, 8081, OLM04.2 Organochlorine Pesticides on the SPB-608 This is the analysis of a 22-component standard containing 20 pesticides and 2 surrogate compounds commonly analyzed…
Key words
bhc, bhcendrin, endrinendosulfan, endosulfanchlordane, chlordaneheptachlor, heptachlorids, idsmethoxychlor, methoxychloraldehyde, aldehydeepoxide, epoxidedieldrin, dieldrinaldrin, aldrinketone, ketonehexane, hexanesulfate, sulfatewords
US EPA Method 608, 8081, OLM04.2 Organochlorine Pesticides on the 20 m x 0.18 mm I.D., 0.36 μm SLB-5ms
Application Report 404 US EPA Method 608, 8081, OLM04.2 Organochlorine Pesticides on the 20 m x 0.18 mm I.D., 0.36 µm SLB-5ms Author: Katherine Stenerson Acquisition System: 9499 Notebook Reference: 1569-040 This is the analysis of a 22-component standard containing…
Key words
bhc, bhcendrin, endrinendosulfan, endosulfanchlordane, chlordaneheptachlor, heptachlorids, idsmethoxychlor, methoxychloraldehyde, aldehydeepoxide, epoxidedieldrin, dieldrinaldrin, aldrinketone, ketonesulfate, sulfatewords, wordskey
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike