Industrial stack emissions often contain semivolatile organic compounds, including polynuclear aromatic hydrocarbons (PAHs), which pose health and environmental risks. Reliable sampling and analysis methods are essential to quantify these contaminants at very low levels and to ensure regulatory compliance. The choice of adsorbent and analytical conditions directly affects detection limits, background interference, and overall data quality.
This work evaluates the performance of Supelpak-2, a purified Amberlite XAD-2 adsorbent, for sampling semivolatile compounds from stack gases under US EPA SW-846 Modified Method 5 conditions. Key goals include verifying the adsorbent’s cleanliness, assessing chromatographable organic background, and demonstrating its suitability for PAH analysis by capillary gas chromatography.
Supelpak-2 adsorbent, when cleaned and handled according to EPA SW-846 Modified Method 5, provides an exceptionally low background for semivolatile compound sampling. Its performance ensures accurate quantification of PAHs from stack emissions, supporting regulatory compliance and environmental monitoring. Continued innovation in adsorbent chemistry and analytical integration will further enhance trace-level semivolatile analysis.
GC, Consumables
IndustriesEnvironmental
ManufacturerMerck
Summary
Importance of the Topic
Industrial stack emissions often contain semivolatile organic compounds, including polynuclear aromatic hydrocarbons (PAHs), which pose health and environmental risks. Reliable sampling and analysis methods are essential to quantify these contaminants at very low levels and to ensure regulatory compliance. The choice of adsorbent and analytical conditions directly affects detection limits, background interference, and overall data quality.
Study Objectives and Overview
This work evaluates the performance of Supelpak-2, a purified Amberlite XAD-2 adsorbent, for sampling semivolatile compounds from stack gases under US EPA SW-846 Modified Method 5 conditions. Key goals include verifying the adsorbent’s cleanliness, assessing chromatographable organic background, and demonstrating its suitability for PAH analysis by capillary gas chromatography.
Methodology
- Adsorbent Preparation: Supelpak-2 resin cleaned according to EPA SW-846 Method 0010 purity criteria.
- Sampling Train: Glass cartridges packed with Supelpak-2 and assembled into Modified Method 5 train for collecting gaseous and particulate semivolatiles at flow rates above 20 L/min.
- Extraction: Cartridges extracted with methylene chloride, spiked with a surrogate standard (2-fluorobiphenyl) to monitor recovery.
- Analysis: Concentrated extracts analyzed by capillary GC with flame ionization detection (GC/FID) under a temperature program from 40 °C to 300 °C.
Instrumentation Used
- Gas Chromatograph: Capillary GC equipped with SPB-5 column (30 m × 0.53 mm ID, 0.50 µm film).
- Detector: Flame ionization detector set at 320 °C.
- Carrier Gas: Helium at 6 cc/min with nitrogen makeup gas at 40 cc/min.
- Adsorbent Cartridges: Glass holders fitted with Supelpak-2 resin.
Main Results and Discussion
- Background Organic Content: Supelpak-2 exhibited a total chromatographable organic (TCO) level of only 0.06 µg/g, significantly lower than other cleaned XAD-2 materials (~18 µg/g).
- Surrogate Recovery: Consistent recovery of 2-fluorobiphenyl confirmed efficient extraction and minimal loss.
- Chromatographic Performance: The selected GC program effectively resolved target PAHs and allowed clear identification of reference compounds (e.g., perylene-d12) used for quantification.
- Method Compliance: Supelpak-2 meets or exceeds EPA SW-846 requirements, which specify a maximum background of 4 µg/g and total semivolatile content under 10 µg/g.
Benefits and Practical Applications of the Method
- High Purity Adsorbent: Reduces background interference, enabling lower detection limits for trace semivolatiles.
- Reproducibility: Standardized cleaning and handling yield consistent results across sampling campaigns.
- Versatility: Applicable to both source emissions testing and ambient/indoor air monitoring of PAHs and other semivolatiles.
- Regulatory Compliance: Directly supports EPA SW-846 Modified Method 5 and related protocols for incinerator and industrial stack testing.
Future Trends and Opportunities
- Advanced Detection: Integration with mass spectrometric detectors (GC/MS) to expand target analyte scope and improve specificity.
- Miniaturized Sampling: Development of lower-flow or passive sampling approaches using Supelpak derivatives for broader environmental monitoring.
- Custom Adsorbent Formulations: Tailored resin chemistries to capture emerging contaminants, such as oxygenated PAHs and halogenated semivolatiles.
- Automation: Coupling adsorbent traps with on-line thermal desorption units to streamline sample introduction and reduce solvent use.
Conclusion
Supelpak-2 adsorbent, when cleaned and handled according to EPA SW-846 Modified Method 5, provides an exceptionally low background for semivolatile compound sampling. Its performance ensures accurate quantification of PAHs from stack emissions, supporting regulatory compliance and environmental monitoring. Continued innovation in adsorbent chemistry and analytical integration will further enhance trace-level semivolatile analysis.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Analyzing Stack Gas Semivolatiles, Using Supelpak-2 Adsorbent and Capillary GC (Modified Method 5, US EPA SW-846)
1997|Merck|Applications
Application Note 86 Analyzing Stack Gas Semivolatiles, Using Supelpak-2 Adsorbent and Capillary GC (Modified Method 5, US EPA SW-846) The demanding detection limits required for air sampling by Modified Method 5 (US EPA SW-846, Method 0010) necessitates extensive cleaning and…
Key words
adsorbent, adsorbentheptane, heptaneincinerator, incineratorcustom, customwilling, willingmeticulous, meticulouscontact, contactnecessitates, necessitatespolynuclear, polynuclearair, airour, ourfulfill, fulfillpolyaromatic, polyaromaticmin, minsemivolatiles
Versatile Amberlite XAD-2 Resin Now Available
1999|Merck|Applications
TheReporter Reprinted from Volume 16, No. 1, 1997 T297021 © 1999 Sigma-Aldrich Co. For more information, or current prices, contact your nearest Supelco subsidiary listed below. To obtain further contact information, visit our website (www.sigma-aldrich.com), see the Supelco catalog, or…
Key words
bead, beadsupelco, supelcoamberlite, amberliteadsorbate, adsorbatechromatographable, chromatographablehydrophobic, hydrophobicmicrospheres, microspheresagglomeration, agglomerationaqueous, aqueousthereporter, thereporterpolynuclear, polynuclearpolyaromatic, polyaromatictail, tailbiphenyls, biphenylsorganic
Analyze Stack Emissions, Using VOST Air Sampling Tubes and Capillary GC
1998|Merck|Technical notes
TheReporter Reprinted from Volume 15, No. 4, 1996 T296034 © 1999 Sigma-Aldrich Co. For more information, or current prices, contact your nearest Supelco subsidiary listed below. To obtain further contact information, visit our website (www.sigma-aldrich.com), see the Supelco catalog, or…
Key words
vost, vosttenax, tenaxtubes, tubessupelco, supelcocharcoal, charcoalpuffilter, puffilterglasswool, glasswoolcontainer, containerarnhem, arnhemenka, enkapuf, pufcartridge, cartridgestorage, storagespecifications, specificationsglass
Dioxin & PCB Analysis
2007|Merck|Brochures and specifications
Dioxin & PCB Analysis Dibenzo-p-dioxins, Dibenzofurans, Polychlorinated Biphenyls Sample Clean up GC Analysis Air Monitoring Resins Solvents 2 Introduction Introduction Figure 1. Dioxin / Furan skeletal structure, can be chlorinated at any of the suitable positions on the aromatic ring…
Key words
dioxin, dioxinpcb, pcbaldrich, aldrichsigma, sigmalayer, layerpkg, pkgsilica, silicadioxins, dioxinspcbs, pcbspolychlorinated, polychlorinatedreversible, reversibleair, airclean, cleanprep, prepflorisil