Analyze Stack Emissions, Using VOST Air Sampling Tubes and Capillary GC
Technical notes | 1998 | MerckInstrumentation
Volatile organic compounds in hazardous waste stack emissions pose serious environmental and health risks. Accurate sampling and analysis methods are critical to monitor and control these pollutants in compliance with regulatory standards such as EPA SW-846.
This work demonstrates the use of Supelco VOST sampling tubes for the volatile organic sampling train in stack gas emissions. It aims to validate the tube design, sampling procedure, and analytical performance under EPA SW-846 Method 0030 and subsequent GC/MS analysis by Method 5041.
The VOST tubes showed consistently low background interference and high adsorbent purity. Calibration at 20 ng and surrogate spikes confirmed efficient capture and recovery of target compounds. The two-stage trap effectively retained both volatile and semivolatile organics while minimizing moisture carryover during thermal desorption.
Emerging developments include integration with automated sampling systems, expansion of analyte libraries to include more polar compounds, and coupling with high-resolution mass spectrometry. Novel adsorbent materials may enhance selectivity, capacity, and moisture resistance for complex emission matrices.
Supelco VOST sampling tubes provide a validated and robust method for measuring volatile organics in industrial stack emissions. Their low background, strong QA/QC performance, and compatibility with established EPA methods make them well suited for both regulatory compliance and research applications.
GC, Consumables
IndustriesEnvironmental
ManufacturerMerck
Summary
Significance of the Topic
Volatile organic compounds in hazardous waste stack emissions pose serious environmental and health risks. Accurate sampling and analysis methods are critical to monitor and control these pollutants in compliance with regulatory standards such as EPA SW-846.
Objectives and Study Overview
This work demonstrates the use of Supelco VOST sampling tubes for the volatile organic sampling train in stack gas emissions. It aims to validate the tube design, sampling procedure, and analytical performance under EPA SW-846 Method 0030 and subsequent GC/MS analysis by Method 5041.
Methodology and Instrumentation
- Sampling system: serial pairing of VOST 100 (Tenax TA) and VOST 200 (Tenax TA plus petroleum charcoal) tubes to capture compounds boiling between 30 and 100 °C.
- Sample volume: 5–20 L per tube pair at 250–1000 mL/min; up to six pairs can be used sequentially for extended sampling.
- Thermal desorption: heating and inert gas purge with transfer to a purge-and-trap water system to protect downstream instrumentation from moisture.
- Analysis: capillary GC/MS following EPA Method 5041; GC conditions include an SPB-624 column, helium carrier gas, and FID detection at 300 °C.
- Quality assurance: background levels below 20 ng per component, surrogate recoveries between 50–150 %, and pressure drop under 8 inches water at 50 cc/min.
Main Results and Discussion
The VOST tubes showed consistently low background interference and high adsorbent purity. Calibration at 20 ng and surrogate spikes confirmed efficient capture and recovery of target compounds. The two-stage trap effectively retained both volatile and semivolatile organics while minimizing moisture carryover during thermal desorption.
Benefits and Practical Applications
- Reliable compliance monitoring of hazardous waste incinerator emissions under EPA SW-846.
- Low detection limits with consistent recoveries across a broad range of volatile organics.
- Customizable tube configurations and adsorbent choices to fit specific sampling needs.
- Reusability after inert gas conditioning, offering cost savings over time.
Future Trends and Applications
Emerging developments include integration with automated sampling systems, expansion of analyte libraries to include more polar compounds, and coupling with high-resolution mass spectrometry. Novel adsorbent materials may enhance selectivity, capacity, and moisture resistance for complex emission matrices.
Conclusion
Supelco VOST sampling tubes provide a validated and robust method for measuring volatile organics in industrial stack emissions. Their low background, strong QA/QC performance, and compatibility with established EPA methods make them well suited for both regulatory compliance and research applications.
Reference
- EPA SW-846 Method 0030: Volatile Organic Sampling Train (VOST).
- EPA Method 5041: Protocol for Analysis of Sorbent Cartridges from VOST.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Analysis of Stack Emissions Using VOST Air Sampling Tubes and Capillary GC
1997|Merck|Applications
Application Note 104 Analysis of Stack Emissions Using VOST Air Sampling Tubes and Capillary GC United States EPA SW-846, Method 0030, Volatile Organic Sampling Train (VOST), describes the sampling of emissions for volatile compounds from hazardous waste incinerator stacks. Supelco’s…
Key words
vost, vosttubes, tubestenax, tenaxemissions, emissionspuf, pufcontainer, containerstack, stackstorage, storageglass, glassmay, mayvolatile, volatilebepolyurethane, bepolyurethaneincinerator, incineratorcompounds, compoundsarnhem
Thermal Desorption Applications Guide for Model 890/891 Thermal Desorption Unit and Dynamic Thermal Stripper
1996|Merck|Guides
Bulletin 873A Thermal Desorption Applications Guide for Model 890/891 Thermal Desorption Unit and Dynamic Thermal Stripper When you use a Supelco Thermal Desorption Unit in combination with a Supelco Dynamic Thermal Stripper, your samples can exist in any physical state…
Key words
thermal, thermaldesorption, desorptionsupelco, supelcostripping, strippingfid, fidmin, minweathered, weatheredstripper, stripperchromatography, chromatographyapplications, applicationsthermally, thermallyadsorbent, adsorbentsparged, spargedtube, tubedesorbed
Purge-and-Trap System Guide
1997||Guides
Bulletin 916 Purge-and-Trap System Guide When determining a problem in your purge-and-trap/GC system, methodical troubleshooting is a must. By following this simple, yet comprehensive process for finding and fixing purge-and-trap problems, you can quickly get your GC system back up…
Key words
purge, purgetrap, trapsupelco, supelcotraps, trapsbtextrap, btextrapdry, drywear, wearthermal, thermalstripper, stripperyour, yourwater, waterdescription, descriptionconcentrator, concentratordesorb, desorbproblem
Adsorbent Trap for GC Analyses of Volatile Organic Compounds in Wastewater
1995|Merck|Applications
Application Note 30 Adsorbent Trap for GC Analyses of Volatile Organic Compounds in Wastewater Adsorbents used in VOCARB purge traps offer superior adsorption/desorption characteristics, thermal stability, and hydrophobicity for monitoring volatile organic compounds (VOCs) in water. Response factors for compounds…
Key words