Agilent JetClean self-cleaning ion source

Brochures and specifications | 2019 | Agilent TechnologiesInstrumentation
GC/MSD, GC/SQ, GC/QQQ
Industries
Manufacturer
Agilent Technologies

Summary

Significance of the Topic


Gas chromatography–mass spectrometry (GC/MS) is essential for trace-level and complex sample analysis, but ion source contamination can impair data quality and reduce instrument availability. Automated self-cleaning technology addresses these issues by minimizing downtime and ensuring consistent performance.

Objectives and Study Overview


This work introduces the Agilent JetClean self-cleaning ion source and evaluates its capacity to reduce or eliminate manual cleaning on Agilent single and triple quadrupole GC/MS systems, assessing impacts on data reproducibility and laboratory efficiency.

Instrumentation Used


  • Agilent single and triple quadrupole GC/MS with JetClean self-cleaning ion source
  • Controlled hydrogen flow mechanism for in situ contamination removal
  • Electron ionization (EI) and chemical ionization (CI) operational modes

Methodology and Protocols


The JetClean system maintains source cleanliness via a regulated hydrogen purge, operating in two modes: clean-only (between runs) and acquire-and-clean (simultaneous analysis and cleaning). Performance was demonstrated through soil extract injections and a five-day, 200-injection evaluation of polyaromatic hydrocarbons (PAHs) in palm oil following a simple toluene extraction.

Main Results and Discussion


  • After hundreds of soil extract injections, sources with JetClean showed no visible deposits, whereas conventional sources accumulated contamination that affected response stability.
  • PAH analysis in palm oil yielded area RSDs below 5% over five days and calibration linearity with R² values above 0.997, indicating high precision and robustness.
  • In a high-throughput metabolomics laboratory, manual source cleanings decreased from 24 to 1 per year—a 90% reduction—substantially improving instrument uptime and reducing operator workload.

Benefits and Practical Applications


  • Increased instrument uptime and productivity through fewer manual maintenance interventions
  • Consistent data quality and run-to-run reproducibility via continuous source cleanliness
  • Enhanced operator convenience and flexible workflows with automated, in situ cleaning
  • Broad applicability across food safety, environmental testing, energy and chemicals, materials science, clinical research, and metabolomics

Future Trends and Opportunities


Integration of automated cleaning with process analytical technology (PAT), predictive maintenance, and remote monitoring can further streamline laboratory workflows. Extending self-cleaning concepts to other mass spectrometry platforms and developing alternative cleaning chemistries may spur future innovations.

Conclusion


The Agilent JetClean self-cleaning ion source effectively minimizes manual maintenance, preserves data integrity, and delivers significant time and cost savings across diverse GC/MS applications.

References


  • Agilent Technologies. 2019. JetClean Self-Cleaning Ion Source Application Note (5991-6873EN Rev. 2.0).

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Agilent JetClean self-cleaning ion source for GC/MS
Turn Cleaning Time into Productive Time Agilent JetClean self-cleaning ion source for GC/MS Remove Matrix Deposits from the Ion Source— Without Removing the Ion Source If your lab runs GC/MS analyses, manually cleaning the ion source is a time-consuming reality.…
Key words
jetclean, jetcleancleaning, cleaningyearly, yearlysource, sourcerevenue, revenuecleanings, cleaningsself, selfper, perion, ionbenzo, benzowage, wagewages, wagesagilent, agilentyour, yourtime
How Much Could Your Lab Save by Cutting Cleaning Time up to 90%?
How Much Could Your Lab Save by Cutting Cleaning Time up to 90%? See for yourself Plug in the numbers that are relevant to your lab and see the actual impact the Select your currency Agilent JetClean self-cleaning ion source…
Key words
jetclean, jetcleancleaning, cleaningyearly, yearlyrevenue, revenuecleanings, cleaningsper, perwage, wagewages, wagesdowntime, downtimesavings, savingscost, costevent, eventloss, lossyour, yoursee
Significant Robustness Improvements of PAHs Analysis in Palm Oil Using the JetClean Self-Cleaning Ion Source in a GC/MS/MS System
Significant Robustness Improvements of PAHs Analysis in Palm Oil Using the JetClean Self-Cleaning Ion Source in a GC/MS/MS System ASMS 2016 Poster WP 209 Michel Lesieur1; Elizabeth Almasi2; Terry Sheehan2; 1Agilent Technologies, Les Ulis, France; 2Agilent Technologies, Santa Clara, CA…
Key words
cleaning, cleaningpalm, palmjetclean, jetcleantoluene, tolueneblank, blankpahs, pahsself, selfsource, sourceoil, oilremained, remainedcounts, countsion, ionoïl, oïlprudently, prudentlycount
JetClean Self cleaning ion source
JetClean Self cleaning ion source
2016|Agilent Technologies|Presentations
ANY ANALYTE, ANY METHOD, ONE PARTNER ONLY AGILENT COVERS ALL YOUR MASS SPEC NEEDS July 13, 2016 Page 1 JetClean Self-cleaning ion source Elizabeth Almasi Applications Manager June 9, 2016 What are your plans for the weekend? Cleaning is a…
Key words
jetclean, jetcleancleaning, cleaningjanuary, januaryoctober, octoberapril, aprilaugust, augustseptember, septembernovember, novembermarch, marchfebruary, februaryjune, juneclean, cleandecember, decemberself, selfsource
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike