Analysis of tocopherol isomer mixture
Applications | 2016 | Trajan ScientificInstrumentation
GC, GC columns, Consumables
IndustriesManufacturerTrajan Scientific
Key wordsSimilar PDF
Analysis of polychlorinated dibenzofurans
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of polychlorinated dibenzofurans BPX5 Column Part Number 054114 Phase BPX5 Rate 3 5°C/min to 330°C Column 50 m x 0.22 mm x 0.25 μm Final temperature 330°C Initial temperature 180°C, 2 min Carrier gas He, 30 psi…
Key words
dibenzofurans, dibenzofuranspolychlorinated, polychlorinatedheptachlorodibenzofurans, heptachlorodibenzofuranshexachlorodibenzofurans, hexachlorodibenzofuranspentachlorodibenzofurans, pentachlorodibenzofuranstetrachlorodibenzofurans, tetrachlorodibenzofuransoctachlorodibenzofurans, octachlorodibenzofuransmin, minnote, notetemperature, temperatureapplication, applicationfinal, finalcolumn, columninitial, initialpart
Analysis of polychlorinated p-dibenzodioxins
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of polychlorinated p-dibenzodioxins BPX5 Column Part Number 054114 Phase BPX5 Rate 3 5°C/min to 330°C Column 50 m x 0.22 mm x 0.25 μm Final temperature 330°C, 6 min Initial temperature 80°C, 2 min Detector MS Rate…
Key words
dibenzodioxins, dibenzodioxinspolychlorinated, polychlorinatedheptachlorodibenzodioxins, heptachlorodibenzodioxinshexachlorodibenzodioxins, hexachlorodibenzodioxinsoctachlorodibenzodioxins, octachlorodibenzodioxinspentachlorodibenzodioxins, pentachlorodibenzodioxinstetrachlorodibenzodioxins, tetrachlorodibenzodioxinsnote, notetemperature, temperatureapplication, applicationfinal, finalcolumn, columninitial, initialpart, partanalysis
Analysis of aniline impurities
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of aniline impurities BPX5 Column part number 054127 Phase BPX5 Rate 2 20°C/min Column 12 m x 0.32 mm x 1.0 μm Final temperature 2 330°C, 10 min Initial temperature 50°C, 1 min Detector FID, 380°C Rate…
Key words
aniline, anilineimpurities, impuritiesinjector, injectorcolumn, columninitial, initialsplit, splitpart, partcomponents, componentscarrier, carrierdetector, detectornumber, numberphase, phasenote, notetemperature, temperaturegas
Analysis of USEPA 502.2 mix
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of USEPA 502.2 mix BPX5 Column part number 054122 Phase BPX5 Carrier gas flow 1.8 mL/min Column 30 m x 0.25 mm x 1.0 μm Constant flow On Sample 200 ppm in methanol Average linear velocity 35…
Key words
xylene, xylenebutylbenzene, butylbenzenebenzene, benzenetemperature, temperatureisopropyltoluene, isopropyltolueneinjection, injectiondibromomethane, dibromomethanebromobenzene, bromobenzeneisopropylbenzene, isopropylbenzenetetrachloroethene, tetrachloroethenetrichloroethene, trichloroethenecarrier, carrierpropylbenzene, propylbenzenedibromochloromethane, dibromochloromethanebromodichloromethane