GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Analysis of aniline impurities

Applications | 2016 | Trajan ScientificInstrumentation
GC, GC columns, Consumables
Industries
Manufacturer
Trajan Scientific
Key words
Downloadable PDF for viewing
 

Similar PDF

Toggle
Analysis of USEPA 8270 mix
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of USEPA 8270 mix BPX5 Column part number 054101 Phase BPX5 Carrier gas flow 1.1 mL/min Column 30 m x 0.25 mm x 0.25 μm Constant flow On Sample 5 ppm solution Injection mode Splitless Initial temperature…
Key words
phthalate, phthalatefluoranthene, fluoranthenebenzo, benzoanthracene, anthracenepyrene, pyrenebutyl, butylpressure, pressurepurge, purgediethylphthalate, diethylphthalatefinal, finalnitrosodiphenylamine, nitrosodiphenylaminecarbazole, carbazoletemperature, temperatureinjection, injectionbenzidine
Analysis of organophosphorous pesticides (USEPA 622)
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of organophosphorous pesticides (USEPA 622) BPX5 Column part number 054142 Phase BPX5 Detector MS Column 30 m x 0.22 mm x 0.25 μm Injection mode Splitless, 0.25 min Initial temperature 50°C, 1 min Carrier gas He, 30…
Key words
chlorpyriphos, chlorpyriphosmethyl, methylstirophos, stirophostokuthion, tokuthionmerphos, merphostrichloronate, trichloronateronnel, ronnelsulprofos, sulprofosfensulfothion, fensulfothiondisulfoton, disulfotonazinphos, azinphoscoumaphos, coumaphosfenthion, fenthionparathion, parathionquad
Analysis of plant sterols
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of plant sterols BPX5 Column part number 054142 Phase BPX5 Detector FID, 360°C Column 30 m x 0.22 mm x 0.25 μm Injection mode Split (100:1) Initial temperature 280°C, 1 min Carrier gas He, 20 psi Rate…
Key words
sterols, sterolsplant, planttemperature, temperatureinjection, injectionfinal, finalinitial, initialcolumn, columnpart, partcarrier, carriercomponents, componentsdetector, detectornumber, numbermode, modevolume, volumerate
Analysis of polychlorinated p-dibenzodioxins
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of polychlorinated p-dibenzodioxins BPX5 Column Part Number 054114 Phase BPX5 Rate 3 5°C/min to 330°C Column 50 m x 0.22 mm x 0.25 μm Final temperature 330°C, 6 min Initial temperature 80°C, 2 min Detector MS Rate…
Key words
dibenzodioxins, dibenzodioxinspolychlorinated, polychlorinatedheptachlorodibenzodioxins, heptachlorodibenzodioxinshexachlorodibenzodioxins, hexachlorodibenzodioxinsoctachlorodibenzodioxins, octachlorodibenzodioxinspentachlorodibenzodioxins, pentachlorodibenzodioxinstetrachlorodibenzodioxins, tetrachlorodibenzodioxinsnote, notetemperature, temperatureapplication, applicationfinal, finalcolumn, columninitial, initialpart, partanalysis
Other projects
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike