Significance of the Topic


The accurate analysis of volatile organic compounds (VOCs) in water and solvent matrices is critical for environmental monitoring, industrial hygiene and quality control. In particular, compounds such as dichloromethane and 1,2-dichloropropane have attracted attention due to their potential carcinogenicity in printing‐process environments. Reliable separation and quantification of these trace‐level analytes support risk assessment, regulatory compliance and efficient process control.

Study Objectives and Overview


This work presents a comparative evaluation of three GL Sciences capillary GC columns—InertCap AQUATIC, InertCap AQUATIC-2 and InertCap 624—in the separation of 33 common water- and solvent‐borne VOCs. The aim was to identify the column offering optimal inertness, peak resolution and analysis speed for routine monitoring of trace organic contaminants in industrial and environmental samples.

Methodology and Instrumentation


Gas chromatography with flame ionization detection (GC-FID) was employed for all experiments.
  • Columns tested: InertCap AQUATIC, InertCap AQUATIC-2 and InertCap 624 (0.25 mm I.D. × 60 m, df = 1.0 μm).
  • Carrier gas: Helium at 200 kPa.
  • Injection: Split mode, 80 mL/min, 0.2 μL analyte solution in methanol.
  • Oven program: 60 °C initial, ramp 4 °C/min to 150 °C, hold 3 min.
  • Detector: FID, range 10^0.

Key Results and Discussion


Chromatographic data showed that InertCap AQUATIC provided the best overall performance in terms of peak shape, inertness and resolution for a 33-component VOC mixture. All target compounds eluted within approximately 24 minutes, with baseline separation of critical isomeric pairs. InertCap AQUATIC-2 and InertCap 624 achieved acceptable separation but exhibited broader peaks and minor tailing for reactive analytes. The superior inert surface of the AQUATIC phase minimized adsorption losses and improved quantitative reproducibility.

Benefits and Practical Applications


Adoption of the InertCap AQUATIC column delivers:
  • Enhanced reliability for trace‐level VOC quantification in water and solvent samples.
  • Robust performance under routine analytical conditions, reducing downtime for column conditioning.
  • Compatibility with existing GC-FID workflows in contract laboratories, printing industry QA/QC and environmental testing.

Future Trends and Applications


Emerging directions include the development of next-generation inert stationary phases with tailored surface chemistries to further reduce analyte–surface interactions. Integration of GC with mass spectrometry (GC-MS) and miniaturized, portable GC systems will expand on-site VOC monitoring capabilities. Additionally, evolving regulatory frameworks may demand validated methods for previously unregulated compounds like 1,2-dichloropropane, driving further application development.

Conclusion


This comparative study demonstrates that the InertCap AQUATIC column outperforms alternative phases for the separation of a broad range of water-soluble and solventborne VOCs using GC-FID. Its high inertness, resolution and analysis speed make it an excellent choice for environmental, industrial and QA/QC laboratories focusing on trace organic contaminant analysis.

Reference


No external literature references were cited in the original application data.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Artificial Photosynthesis -Photocatalyst Characterization and Product Quantification
C10G-E104 Analytical Solutions for Artificial Photosynthesis -Photocatalyst Characterization and Product Quantification- Toward a Carbon Neutral Society What’s Artificial Photosynthesis Artificial photosynthesis is a technology that artificially performs photosynthesis using photocatalysts and sunlight. It is expected to be a next-generation renewable…
Key words
chromatograph, chromatographphotoreaction, photoreactionphotosynthesis, photosynthesisフォトン, フォトンreaction, reactiongas, gasmeasurement, measurementlightway, lightwayquantum, quantumスペクトル, スペクトルphotons, photonshydrogen, hydrogenproduct, productサービス, サービスmicropacked
TurboVap (Safety Translations)
TurboVap (Safety Translations)
2019|Biotage|Manuals
TurboVap ® Safety Translations Contents TurboVap ® Safety Translations CONTENTS 1 3 6 9 12 15 2 安全 安全性について Sécurité Seguridad Sicherheitshinweise Sicurezza TurboVap Safety Translations | © Biotage 2019 ® 安全 安全 注意:这是英语版“TurboVap Installation and Safety”文档中 “Safety”一章的翻译。如有任何出入,以英语原版为准。 ® 使用目的…
Key words
システム, システムbiotage, biotagesistema, sistemadel, deldes, desund, undsystème, systèmeles, lesder, derturbovap, turbovapdie, dierohs, rohslas, lassie, siecon
Inlet Liner Removal Tool (MANUAL)
ERAD-0001-9083A P/N:227-35032-01 Inlet Liner Removal Tool INSTRUCTION MANUAL The Inlet Liner Removal Tool is designed to simplify and efficiently facilitate the removal of gas chromatography (GC) inlet liners. Applicable liner outer diameter : 5 mm Recommended operating temperature : Room…
Key words
インサート, インサートリング, リングインジェクションポート, インジェクションポートツール, ツールliner, linerインサートリムーバルツール, インサートリムーバルツールピンセット, ピンセットplease, pleasetweezers, tweezersring, ringport, portremoval, removalcareful, carefulガスクロマトグラフ, ガスクロマトグラフガラスインサー
GC Columns Installation Guide
Innovative Chromatography Solutions GC Columns Installation Guide GC Column Installation 气相色谱柱安装指南 Instructions pour l’installation d’une colonne capillaire Einbau einer GC-Kapillarsäule Istruzioni per l’installazione di una colonna capillare Instalación de Columnas Capilares GCカラム取付け手順 www.restek.com/gc 2 GC Column Installation Instructions The Restek…
Key words
カラム, カラムcolonna, colonnacolonne, colonnedella, dellarestek, restekcolumna, columnader, derpour, pouruna, unapara, paradel, delキャリヤガス, キャリヤガスcapillaire, capillaireフェルール, フェルールtempérature
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike