Optimized Method Development of Large Volume Injection for GC/MS/MS of Food Pesticides
Applications | 2012 | Agilent TechnologiesInstrumentation
The accurate and sensitive detection of pesticide residues in food is critical for public health and regulatory compliance.
Large volume injection (LVI) enhances analyte mass on-column, achieving lower detection limits and improved signal-to-noise ratios compared with traditional splitless injections.
The optimized LVI approach provides robust multi-residue pesticide screening in complex food matrices with enhanced sensitivity and improved peak quality.
It supports compliance with increasingly stringent regulatory limits, including low MRLs in baby food analysis, and extends column and ion source life by reducing solvent load.
Optimized large volume injection on GC/MS/MS, combined with inert flow paths and targeted inlet conditions, significantly improves pesticide residue analysis in food.
This method achieves lower detection limits, better chromatographic performance for early eluters, and reliable quantitative repeatability, offering a valuable tool for food safety testing and regulatory monitoring.
GC/MSD, GC/MS/MS, GC/QQQ
IndustriesFood & Agriculture
ManufacturerAgilent Technologies
Summary
Significance of the Topic
The accurate and sensitive detection of pesticide residues in food is critical for public health and regulatory compliance.
Large volume injection (LVI) enhances analyte mass on-column, achieving lower detection limits and improved signal-to-noise ratios compared with traditional splitless injections.
Objectives and Study Overview
- Develop and optimize an LVI-based GC/MS/MS method for trace-level pesticide analysis in food matrices.
- Evaluate key injection parameters to minimize solvent effects and preserve chromatographic performance.
- Compare the optimized LVI approach with hot and cold splitless injections in terms of sensitivity and peak quality.
- Demonstrate method performance using a pepper matrix prepared via QuEChERS.
Methodology
- Sample Preparation: QuEChERS extraction of food matrices using acetonitrile acidified with 1% acetic acid.
- LVI Optimization: Employed Agilent Multimode Inlet solvent vent mode to adjust vent flow, vent pressure, inlet temperature, vent time, and injection rate.
- Injection Volume: 5 μL large volume vs. 1 μL in splitless modes.
- Parameter Optimization: Vent flow set to 100 mL/min; vent pressure 2.5 psi; inlet temperature 75 °C; vent time ~0.085 min; calculated injection rate ~69 μL/min.
Instrumentation
- GC System: Agilent 7890 Series GC with Agilent 7693B autosampler.
- Inlet: Agilent Multimode Inlet (MMI) equipped with Ultra Inert deactivated liner with wool and comparison dimple liner.
- Column: Agilent J&W HP-5ms Ultra Inert, 0.25 mm × 15 m, 0.25 μm film.
- Detection: Agilent 7000 Series Triple Quadrupole GC/MS/MS in MRM mode with backflushing capability.
Main Results and Discussion
- The optimized LVI method achieved base peak shape improvements for early eluting, low-volatility pesticides by reducing solvent-induced distortion.
- Sensitivity was enhanced, lowering detection limits to 1 ng/mL for all 33 studied pesticides, compared to higher limits in splitless modes.
- Matrix validation in pepper extracts demonstrated clear chromatographic profiles at trace levels and acceptable repeatability (RSD <15% for most compounds).
- Frequent liner replacement and thorough sample cleanup were identified as necessary to mitigate matrix accumulation from larger injection volumes.
Benefits and Practical Applications
The optimized LVI approach provides robust multi-residue pesticide screening in complex food matrices with enhanced sensitivity and improved peak quality.
It supports compliance with increasingly stringent regulatory limits, including low MRLs in baby food analysis, and extends column and ion source life by reducing solvent load.
Future Trends and Potential Applications
- Integration of software-driven calculators and automated inlet control for streamlined LVI method setup.
- Development of advanced inert liners and surface coatings to further reduce analyte adsorption and matrix effects.
- Application of LVI to other challenging analyte classes and coupling with high-resolution mass spectrometry for non-targeted screening.
- Adoption of miniaturized or multiplexed systems for high-throughput routine and regulatory laboratories.
Conclusion
Optimized large volume injection on GC/MS/MS, combined with inert flow paths and targeted inlet conditions, significantly improves pesticide residue analysis in food.
This method achieves lower detection limits, better chromatographic performance for early eluters, and reliable quantitative repeatability, offering a valuable tool for food safety testing and regulatory monitoring.
References
- Agilent Multimode Inlet Large Volume Injection Tutorial, Agilent Technologies, Inc., Part G3510-90020 (2009).
- B. Wilson, C.-K. Meng, Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI), Agilent Application Note 5990-4169EN (2009).
- L. Zhao, D. Mao, Analysis of Pesticides in Food by GC/MS/MS Using the Ultra Inert Liners with Wool, Agilent Application Note 5990-7706EN (2011).
- L. Zhao, C.-K. Meng, Quantitative and Repeatability Analysis of Trace Level Pesticides in Plantation Food by GC/MS/MS, Agilent Application Note 5990-9317EN (2011).
- M.J. Szelewski, B. Quimby, New Tools for Rapid Pesticide Analysis in High Matrix Samples, Agilent Application Note 5989-1716EN (2011).
- C.-K. Meng, Improving Productivity and Extending Column Life with Backflush, Agilent Application Note 5989-6018EN (2006).
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Analysis of Trace Level Pesticides in Fruits and Vegetable by GC/MS/MS Using Agilent Ultra Inert Liners with Wool
2011|Agilent Technologies|Posters
Analysis of Trace Level Pesticides in Fruits and Vegetable by GC/MS/MS Using Agilent Ultra Inert Liners with Wool FPRW 2011 Poster P-75 Agilent Technologies Inc., 2850 Centerville Road, Wilmington, DE 19808 USA Other features of Agilent Ultra Inert Liners •…
Key words
wool, woolomenthoate, omenthoateinert, inertpepper, pepperendrin, endrinrelative, relativeultra, ultraliners, linersdimenthoate, dimenthoatehsl, hslliner, linerlvi, lvicsl, cslpesticides, pesticidesdichlorfluanid
Making a Grand Entrance: Techniques for Efficient Sample Introduction, Inlet Types, and Maintenance
2020|Agilent Technologies|Presentations
Making a Grand Entrance: Techniques for Efficient Sample Introduction, Inlet Types, and Maintenance Mark Sinnott – Application Engineer Alexander Ucci - Application Engineer March 19, 2019 1 March 29, 2019 Techniques for Efficient Sample Introduction Agilent Restricted Sample Injection Goals…
Key words
restricted, restrictedefficient, efficienttechniques, techniquessplitless, splitlessagilent, agilentsplit, splitsample, sampleintroduction, introductioninlet, inletliner, linervent, ventcolumn, columndiscrimination, discriminationsolvent, solventseptum
Understanding the GC Inlet: Which Type is Most Appropriate for your Method?
2021|Agilent Technologies|Presentations
Understanding the GC Inlet: Which Type is Most Appropriate for your Method? Mark Sinnott Agilent Technologies Application Engineer April 22, 2021 1 DE44305-5966666667 Sample Injection Goals •Introduce sample into the column •Reproducible •Minimize efficiency losses •Representative of sample Page 2…
Key words
splitless, splitlesssplit, splitinlet, inletliner, linervent, ventsolvent, solventpulsed, pulsedseptum, septumcolumn, columninjections, injectionscold, coldinjection, injectionliners, linerswool, woolpurge
Understanding the Inlets - How to Choose the Right One!
2013|Agilent Technologies|Presentations
Understanding the Inlets How to Choose the Right One! Abby Folk Application Engineer Agilent Technologies, Inc. October 2, 2013 Types of Inlets Purged Packed Split / Splitless Agilent Inert Flow Path Solutions!!! Cool On Column Programmable Temperature Vaporization Volatiles Interface…
Key words
splitless, splitlessinlet, inletsplit, splitinjections, injectionssolvent, solventcoc, cocpulsed, pulseddiscrimination, discriminationvent, ventcold, coldliner, linerinjection, injectioncolumn, columnpulse, pulsemmi