Semivolatiles Retention Time Locked (RTL) Deconvolution Databases for Agilent GC/MSD Systems
Applications | 2008 | Agilent TechnologiesInstrumentation
Environmental analysis of semivolatile organic compounds in complex matrices requires reliable identification and quantitation. Retention time locking combined with spectral deconvolution reduces analysis time and false positives, ensuring consistent results across instruments and laboratories. These capabilities are critical for regulatory compliance and high-throughput monitoring.
This study presents the G1677AA Semivolatiles Retention Time Locked database and its integration with Agilent Deconvolution Reporting Software. It covers separate libraries for wastewater (EPA 8270) and drinking water (EPA 525) methods, aiming to accelerate confirmation of environmental contaminants using full-scan deconvolution and locked retention times.
The RTL databases enable rapid confirmation of 273 semivolatile compounds (EPA 8270 plus 30 additional) and 119 compounds (EPA 525) in complex environmental matrices. Retention time locking enhances reproducibility, supports automated exclusion of out-of-window peaks, and removes the need for manual SIM window adjustment. Two workflows for systems without RTL are proposed: manual calibration file editing or automated AMDIS database updates.
Anticipated advances include expansion of RTL libraries to emerging pollutants, integration with high-resolution mass spectrometry, machine-learning-enhanced deconvolution, cloud-based library sharing, and hybrid full-scan/SIM acquisition to optimize sensitivity and specificity.
The G1677AA Semivolatiles Retention Time Locked database with Agilent Deconvolution Reporting Software streamlines semivolatile contaminant screening in environmental samples. By combining retention time locking, full-scan deconvolution, and flexible quantitation, it provides a robust platform for regulatory compliance and efficient laboratory workflows.
GC/MSD, GC/SQ, Software
IndustriesEnvironmental
ManufacturerAgilent Technologies
Summary
Importance of the Topic
Environmental analysis of semivolatile organic compounds in complex matrices requires reliable identification and quantitation. Retention time locking combined with spectral deconvolution reduces analysis time and false positives, ensuring consistent results across instruments and laboratories. These capabilities are critical for regulatory compliance and high-throughput monitoring.
Objectives and Study Overview
This study presents the G1677AA Semivolatiles Retention Time Locked database and its integration with Agilent Deconvolution Reporting Software. It covers separate libraries for wastewater (EPA 8270) and drinking water (EPA 525) methods, aiming to accelerate confirmation of environmental contaminants using full-scan deconvolution and locked retention times.
Methodology and Instrumentation
- Software: MSD ChemStation Rev E.02 and later, DRS G1716AA, AMDIS with NIST spectral library
- Gas chromatograph: Agilent 6890N or 7890A with splitless or programmable temperature vaporization inlet
- Mass spectrometer: Agilent 5975 MSD with autotune, mass range 35–500 amu
- Columns: 20 m DB-5.625 (0.18 mm × 0.36 µm) for splitless, 30 m HP-5MSi (0.25 mm × 0.25 µm) for PTV large-volume injection
- RTL anchor compound: phenanthrene-d10 locked at 9.500 min (splitless) or 12.700 min (PTV)
- Acquisition: full-scan for deconvolution and optional SIM for targeted quantitation
Key Results and Discussion
The RTL databases enable rapid confirmation of 273 semivolatile compounds (EPA 8270 plus 30 additional) and 119 compounds (EPA 525) in complex environmental matrices. Retention time locking enhances reproducibility, supports automated exclusion of out-of-window peaks, and removes the need for manual SIM window adjustment. Two workflows for systems without RTL are proposed: manual calibration file editing or automated AMDIS database updates.
Benefits and Practical Applications
- Unified reporting through combined AMDIS deconvolution, NIST library search, and ChemStation quantitation
- Adaptable methods for different inlet types and laboratory requirements
- Library extensibility by user addition of compounds and spectra
- Decreased data review time and lower false positive rate in environmental testing
Future Trends and Opportunities
Anticipated advances include expansion of RTL libraries to emerging pollutants, integration with high-resolution mass spectrometry, machine-learning-enhanced deconvolution, cloud-based library sharing, and hybrid full-scan/SIM acquisition to optimize sensitivity and specificity.
Conclusion
The G1677AA Semivolatiles Retention Time Locked database with Agilent Deconvolution Reporting Software streamlines semivolatile contaminant screening in environmental samples. By combining retention time locking, full-scan deconvolution, and flexible quantitation, it provides a robust platform for regulatory compliance and efficient laboratory workflows.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
7890-5975 MSD DRS Semivolatiles Analyzer, Minimizing Start-up Time
2010|Agilent Technologies|Presentations
7890-5975 MSD DRS Semivolatiles Analyzer, Analyzer Minimizing Start-up Time Mike Szelewski 2010.09.28 Hardware, Software and Methods Details SP 7890-0459 What is an Analyzer ? 1. A complete system designed for an application 2. Analyzers available with GC only, GC-MSD and…
Key words
amdis, amdisdrs, drssemivolatiles, semivolatilesanalyzer, analyzercheckout, checkoutmmi, mmisplitless, splitlessmsd, msdrestrictor, restrictorspectra, spectrattrained, ttrainedbleeder, bleederquant, quantcold, coldrtlock
Screening for Hazardous Chemicals in Homeland Security and Environmental Samples Using a GC/MS/ECD/FPD with a 731 Compound DRS Database
2006|Agilent Technologies|Applications
Screening for Hazardous Chemicals in Homeland Security and Environmental Samples Using a GC/MS/ECD/FPD with a 731 Compound DRS Database Application Note Homeland Security, Environmental Authors Bruce Quimby Mike Szelewski Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE 19808 UASA Abstract…
Key words
methyl, methylfpd, fpdamdis, amdissim, simester, esterphthalate, phthalatemsd, msdsplit, splitscan, scanecd, ecddfpd, dfpdsplitter, splitterhazardous, hazardousparathion, parathionepc
Screening for 926 Pesticides and Endocrine Disruptors by GC/MS with Deconvolution Reporting Software and a New Pesticide Library
2006|Agilent Technologies|Applications
Screening for 926 Pesticides and Endocrine Disruptors by GC/MS with Deconvolution Reporting Software and a New Pesticide Library Application Note Food and Environmental Authors USA endocrine disrupters in about two minutes per sample. Deconvolution helps identify pesticides that are buried…
Key words
methyl, methylester, esterdrs, drsphthalate, phthalatesulfone, sulfoneamdis, amdisoxon, oxonethyl, ethylisomer, isomeragilent, agilentdatabase, databasedeconvolution, deconvolutionpesticide, pesticidelibrary, librarycas
Reducing Analysis Time Using GC/MSD and Deconvolution Reporting Software
2007|Agilent Technologies|Applications
Reducing Analysis Time Using GC/MSD and Deconvolution Reporting Software Application Food and Flavors Authors Mike Grady, Steve Morrison, and Bob Deets Campbell Soup Company Campbell Place Camden, NJ 08103 USA Mike Szelewski Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE…
Key words
msd, msddrs, drswashes, washessolv, solvcampbell, campbellpermethrin, permethrindeconvolution, deconvolutionfewest, fewestcryo, cryolocked, lockednegatives, negativespositives, positivespostinj, postinjpreinj, preinjvent