Detection Limits of EPA Method 8260 with Static and Dynamic Headspace GC/MS Analysis
Aplikace | 2015 | Teledyne LABSInstrumentation
GC/MSD, HeadSpace, GC/IT
IndustriesŽivotní prostředí
ManufacturerTeledyne LABS
Key wordstemp, static, dynamic, time, headspace, platen, pressurize, desorb, sweep, fill, mode, inject, epa, detection, analyzer, heat, tic, loop, mix, setting, either, valve, chromatograms, limits, oven, excellent, transfer, total, sample, line, provides, both, each, conclusion, rate, instrument, concentration, experimental, compounds, ion, references, flow, standard, conditions, method, results, analysis
Similar PDF
A Survey of Residual Solvents in Various Inks used in Consumer Product Packaging
2011|Thermo Fisher Scientific|Aplikace
A Survey of Residual Solvents in Various Inks used in Consumer Product Packaging Application Note Abstract Food manufacturers use various printing inks on their consumer product packaging. These inks are typically used on the outside of the package, but are…
Key words
residual, residualstatic, staticdynamic, dynamiccrisping, crispingvocs, vocstemp, tempinks, inksconsumer, consumerpackaging, packagingsandwich, sandwichmicrowavable, microwavabletop, topprinting, printingtetrachloroethane, tetrachloroethanedsq
Using the Teledyne Tekmar HT3TM Headspace Analyzer to Meet the Requirements of the New Korean Standard Method for Water Pollution, ES04602.1, for Bromoform, Vinyl Chloride and Acrylonitrile
2011|Agilent Technologies|Aplikace
Using the Teledyne Tekmar HT3TM Headspace Analyzer to Meet the Requirements of the New Korean Standard Method for Water Pollution, ES04602.1, for Bromoform, Vinyl Chloride and Acrylonitrile Application Note Abstract The Ministry of Environment of the Republic of Korea recently…
Key words
temp, temppreheat, preheattrap, trapacrylonitrile, acrylonitriletime, timepressurize, pressurizemixing, mixingbake, bakedesorb, desorbloop, loopmixer, mixerkorean, koreanequil, equilsweep, sweepplaten
Using the Teledyne Tekmar HT3TM Headspace Analyzer to Meet the Requirements of the Korean Standard Method for Drinking Water, ES05602.3, for 1,4-Dioxane
2011|Agilent Technologies|Aplikace
Using the Teledyne Tekmar HT3TM Headspace Analyzer to Meet the Requirements of the Korean Standard Method for Drinking Water, ES05602.3, for 1,4-Dioxane Application Note Abstract The Ministry of Environment of the Republic of Korea recently updated the Korean Standard Method…
Key words
pressurize, pressurizeloop, loopkorean, koreanequil, equilmdl, mdltemp, temptime, timestatic, staticfill, fillmixing, mixingseven, sevendrinking, drinkingsim, simstandard, standardheadspace
Evaluating Food Products for Furan and Other Volatile Organic Compounds
2011|Thermo Fisher Scientific|Aplikace
Evaluating Food Products for Furan and Other Volatile Organic Compounds Application Note Abstract The US Food and Drug Administration (FDA) published the results of a survey of furan in canned and jarred foods that undergo heat treatment in 2004. In…
Key words
furan, furanfda, fdatemp, tempstatic, staticheadspace, headspacedecaffeinated, decaffeinatedfood, foodamt, amtregular, regularplaten, platenbroth, brothdynamic, dynamicsample, samplefoods, foodschicken