GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Using RTL and 3-Way Splitter to Identify Unknown in Strawberry Extract

Applications | 2006 | Agilent TechnologiesInstrumentation
GC, GC/MSD, GC/SQ
Industries
Food & Agriculture
Manufacturer
Agilent Technologies

Summary

Importance of the Topic


Fruit and vegetable extracts present complex matrices requiring sensitive and selective detection of pesticide residues at trace levels. Implementing retention time locking and a three way splitter enhances simultaneous monitoring with multiple detectors while preserving chromatographic fidelity.

Study Objectives and Overview


The application brief aims to demonstrate the identification of an unknown pesticide in strawberry extract by combining an inert three way splitter with retention time locked gas chromatography and selective detectors. The approach enables up to four parallel signals from a single injection for comprehensive screening.

Methodology and Instrumentation


The analytical setup includes an Agilent 7890A gas chromatograph with split splitless inlet, a three way splitter directing effluent to micro electron capture detector and dual flame photometric detector monitoring sulfur and phosphorus channels, alongside a 5975C mass selective detector. Retention time locking ensures reproducible elution times matched against the RTL pesticide database. Deconvolution Reporting Software processes SIM and full scan data for confirmation.

Main Results and Discussion


An unknown peak at approximately 41 minutes exhibited responses in the ECD and FPD channels but was absent in the full scan total ion chromatogram. Searching the RTL pesticide library within a 0.5 minute window identified temephos as a candidate. Extracted ion chromatograms of the target ion 466 and qualifier ions 125 93 and 109 confirmed co elution at the locked retention time despite low signal intensity.

Benefits and Practical Applications


  • Simultaneous multi detector acquisition increases confidence in trace residue screening
  • Retention time locking streamlines library matching without full scan spectra
  • Enhanced throughput for high matrix samples through single injection workflows
  • Applicable to routine pesticide monitoring in food safety and environmental laboratories

Future Trends and Applications


Emerging developments include expansion of RTL libraries with broader compound coverage high resolution mass spectrometry integration and advanced deconvolution algorithms. Automation of data processing and cloud based spectral matching will further accelerate routine screening in quality assurance and regulatory compliance.

Conclusion


The combination of a three way splitter with retention time locked gas chromatography and selective detectors provides a robust platform for identifying unknown trace pesticides in complex matrices. This approach enhances sensitivity reliability and throughput in pesticide residue analysis.

Instrumentation


  • Agilent 7890A gas chromatograph with split splitless inlet
  • Three way capillary flow splitter
  • Micro electron capture detector
  • Dual flame photometric detector for sulfur and phosphorus channels
  • Agilent 5975C mass selective detector

References


  • Chin Kai Meng and Bruce Quimby Identifying Pesticides with Full Scan SIM ECD and FPD from a Single Injection Application Note 5989 3299 July 2005
  • Mike Szelewski and Bruce Quimby New Tools for Rapid Pesticide Analysis in High Matrix Samples Application Note 5989 1716 October 2004

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Capillary Flow Technology: Splitters
Capillary Flow Technology: Splitters
2013|Agilent Technologies|Brochures and specifications
Capillary Flow Technology: Splitters GET MORE INFORMATION IN LESS TIME A time-saving alternative to running samples on multiple GCs Analyzing complex samples may require different types of specific GC detectors in order to meet detection limits, overcome matrix interferences, or…
Key words
splitter, splitterepc, epcaux, auxmakeup, makeupbackflush, backflushway, waydetectors, detectorscolumn, columngas, gassplitters, splitterspcm, pcmtwo, twodfpd, dfpdagilent, agilenteffluent
Screening for Hazardous Chemicals in Homeland Security and Environmental Samples Using a GC/MS/ECD/FPD with a 731 Compound DRS Database
Screening for Hazardous Chemicals in Homeland Security and Environmental Samples Using a GC/MS/ECD/FPD with a 731 Compound DRS Database Application Note Homeland Security, Environmental Authors Bruce Quimby Mike Szelewski Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE 19808 UASA Abstract…
Key words
methyl, methylfpd, fpdamdis, amdissim, simester, esterphthalate, phthalatemsd, msdsplit, splitscan, scanecd, ecddfpd, dfpdsplitter, splitterhazardous, hazardousparathion, parathionepc
Replacing Multiple 50-Minute GC and GC-MS/SIM Analyses with One 15-Minute Full-Scan GC-MS Analysis for Nontargeted Pesticides Screening and >10x Productivity Gain
Replacing Multiple 50-Minute GC and GC-MS/SIM Analyses with One 15-Minute Full-Scan GC-MS Analysis for Nontargeted Pesticides Screening and >10x Productivity Gain Application Food Safety Author Introduction Chin-Kai Meng and Mike Szelewski Agilent Technologies 2850 Centerville Road Wilmington, DE 19808 To…
Key words
cfsan, cfsanµecd, µecddeconvolution, deconvolutionfda, fdasplitter, splitteramdis, amdisspectrum, spectrumtid, tidpeach, peachginseng, ginsengagilent, agilentfpd, fpdthree, threelibrary, libraryflow
Excellent choices for environmental applications
Excellent choices for environmental applications
2009|Agilent Technologies|Guides
Solutions that meet your demands for: speed accuracy productivity Excellent choices for environmental applications Productivity Tools Applications > Return to Table of Contents > Search entire document Integrated Second Peristaltic Pump for Improved Sample Throughput and Reduced Matrix Effects Technical…
Key words
rtl, rtlpressure, pressuretime, timecolumn, columnaed, aedmethod, methodlocking, lockingagilent, agilentrtlock, rtlockretention, retentionicp, icpinlet, inletcan, canmsd, msdflow
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike