Analysis of Fragrance Allergens
Applications | 2023 | ShimadzuInstrumentation
The reliable identification and quantification of fragrance allergens is essential for consumer safety, regulatory compliance and quality control in cosmetics and personal care products. Fragrance ingredients can elicit contact dermatitis and other allergic reactions, making the monitoring of regulated substances critical under EU Regulation EC 1223/2009 and IFRA guidelines.
This study demonstrates a robust GC-MS method for the simultaneous separation and detection of 57 common fragrance allergens. The goal is to provide a validated analytical protocol that meets EU labeling requirements and offers high sensitivity, reproducibility and throughput for routine laboratory use.
The analytical protocol uses a split injection GC-MS system with the following parameters:
Mass spectrometric detection is performed in full-scan mode with:
The optimized method achieved baseline separation of all 57 target fragrance compounds including monoterpenes, aldehydes, alcohols, esters and macrocyclic musks. Retention times ranged from 2.5 min for α-pinene to 30 min for high-boiling lactones. Two internal standards ensured precise quantitation across a broad volatility range. Key observations:
Reproducibility tests yielded relative standard deviations below 5 % for retention times and peak areas, confirming method robustness.
This GC-MS approach offers laboratories a single-run solution for compliance testing of fragrance allergens. Advantages include:
It supports cosmetic manufacturers, contract testing labs and regulatory bodies in meeting labeling obligations and ensuring product safety.
Advances likely to enhance fragrance allergen analysis include:
The presented GC-MS method on an SH-I-17 column provides a validated, high-throughput platform for fragrance allergen analysis. Its robustness, sensitivity and regulatory alignment make it a valuable tool in quality assurance and safety assessment of consumer products.
GC/MSD, GC/SQ, Consumables, GC columns
IndustriesFood & Agriculture
ManufacturerShimadzu
Summary
Importance of the Topic
The reliable identification and quantification of fragrance allergens is essential for consumer safety, regulatory compliance and quality control in cosmetics and personal care products. Fragrance ingredients can elicit contact dermatitis and other allergic reactions, making the monitoring of regulated substances critical under EU Regulation EC 1223/2009 and IFRA guidelines.
Objectives and Study Overview
This study demonstrates a robust GC-MS method for the simultaneous separation and detection of 57 common fragrance allergens. The goal is to provide a validated analytical protocol that meets EU labeling requirements and offers high sensitivity, reproducibility and throughput for routine laboratory use.
Methodology and Instrumentation
The analytical protocol uses a split injection GC-MS system with the following parameters:
- Column: SH-I-17 capillary (30 m × 0.25 mm I.D., 0.25 µm film thickness)
- Carrier Gas: Helium at a linear velocity of 40 cm/s
- Temperature Program: 80 °C (1 min); ramp 10 °C/min to 135 °C (2 min); ramp 3 °C/min to 170 °C (1 min); ramp 10 °C/min to 280 °C (2 min)
- Injection: Split, 1 µL at 280 °C
Mass spectrometric detection is performed in full-scan mode with:
- Ion source temperature: 200 °C
- Interface temperature: 280 °C
- Emission current: 20 µA
Main Results and Discussion
The optimized method achieved baseline separation of all 57 target fragrance compounds including monoterpenes, aldehydes, alcohols, esters and macrocyclic musks. Retention times ranged from 2.5 min for α-pinene to 30 min for high-boiling lactones. Two internal standards ensured precise quantitation across a broad volatility range. Key observations:
- Mono- and sesquiterpenes eluted within the first 10 min with sharp peaks and minimal co-elution.
- Aromatic aldehydes and alcohols showed strong mass spectral responses, facilitating low-µg/L detection limits.
- Macrocyclic musks such as galaxolide and tonalide were resolved into distinct isomers (52-a, 52-b).
Reproducibility tests yielded relative standard deviations below 5 % for retention times and peak areas, confirming method robustness.
Benefits and Practical Applications
This GC-MS approach offers laboratories a single-run solution for compliance testing of fragrance allergens. Advantages include:
- Comprehensive scope covering regulated and non-regulated compounds.
- High sensitivity and accuracy for trace analysis in complex matrices.
- Efficient run time allowing over 30 samples per day.
It supports cosmetic manufacturers, contract testing labs and regulatory bodies in meeting labeling obligations and ensuring product safety.
Future Trends and Opportunities
Advances likely to enhance fragrance allergen analysis include:
- Integration of two-dimensional GC for even greater separation capacity.
- Automated data processing and AI-driven spectral deconvolution.
- Miniaturized GC-MS systems for on-site or field testing.
- Development of hybrid detectors for simultaneous structural and quantitative information.
Conclusion
The presented GC-MS method on an SH-I-17 column provides a validated, high-throughput platform for fragrance allergen analysis. Its robustness, sensitivity and regulatory alignment make it a valuable tool in quality assurance and safety assessment of consumer products.
Použitá instrumentace
- GC-MS System: Shimadzu GCMS-QP2020 NX
- Column: SH-I-17 (30 m × 0.25 mm I.D., 0.25 µm; P/N 221-75907-30)
- Injection Method: Split, 1 µL at 280 °C
- Carrier Gas: He, linear velocity control
- MS Conditions: Ion source 200 °C, Interface 280 °C, Emission current 20 µA
Reference
- Shimadzu Corporation. Application News 01-00526 (JP, ENG), First Edition Sep. 2023.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Analysis of Fragrance Allergens - No. 476
2023|Shimadzu|Applications
ERAS-1000-0476 GC-MS SH Series SH-1 476 Analysis of Fragrance Allergens Keywords: EC 1223/2009, G/TBT/N/EU/ 924, IFRA 18-a, 19 1,5 3 4 2 8 2.5 67 10 15 11 9 12, 17 13 IS-1 5.0 7.5 16 1418-b20 21 24 27…
Key words
damascone, damasconebenzyl, benzylsalicylate, salicylateacetate, acetatealcohol, alcoholsantalol, santalolcinnamaldehyde, cinnamaldehydepinene, pineneamyl, amyltetramethylacetyloctahydronaphthalene, tetramethylacetyloctahydronaphthalenedimethylbenzylcarbinyl, dimethylbenzylcarbinylhexadecanolactone, hexadecanolactonemethylpropional, methylpropionalamylcinnamyl, amylcinnamylbenzenepropanol
Highly Sensitive Analysis of Fragrance Allergens in Cosmetics Using Triple Quadrupole GCMS
2023|Shimadzu|Applications
GC-MS GCMS-TQ™8040 NX Application News Highly Sensitive Analysis of Fragrance Allergens in Cosmetics Using Triple Quadrupole GCMS Yuto Nakasuji User Benefits Fragrance allergens in cosmetics can be analyzed with high sensitivity using the MRM mode of the triple quadrupole…
Key words
damascone, damasconebenzyl, benzylsalicylate, salicylatemrm, mrmacetate, acetatecosmetics, cosmeticsfragrance, fragrancesantalol, santalolalcohol, alcoholnews, newscinnamaldehyde, cinnamaldehydegeranyl, geranylhair, hairallergens, allergenssim
Quantitative Analysis of 57 Fragrance Allergens in Cosmetics Using Twin Line MS System
2023|Shimadzu|Applications
GC-MS GCMS-QP2020 NX Application News Quantitative Analysis of 57 Fragrance Allergens in Cosmetics Using Twin Line MS System Yuto Nakasuji and Takahide Hiramatsu User Benefits The twin line MS system enables efficient analysis of fragrance allergens in cosmetics. …
Key words
デフォルト, デフォルトfragrance, fragrancetwin, twinsalicylate, salicylatearea, areaallergens, allergenshair, hairdamascone, damasconecosmetics, cosmeticsamyl, amylneral, neralnews, newsbenzyl, benzylcitronellol, citronellolline
Analysis of Allergens in Fragrance Samples Using a Comprehensive GCxGC in Combination with a High-Resolution Mass Spectrometry
2025|Agilent Technologies|Posters
Poster Reprint ASMS 2025 Poster number MP 353 Analysis of Allergens in Fragrance Samples Using a Comprehensive GCxGC in Combination with a High-Resolution Mass Spectrometry Sofia Nieto; Matthew Curtis and Nick Harden Agilent Technologies, Santa Clara, CA Introduction Fragrances are…
Key words
benzyl, benzylsalicylate, salicylateallergens, allergensalcohol, alcoholsantalol, santaloldamascone, damasconegcxgc, gcxgcacetate, acetatepinene, pinenefid, fidsplitter, splitterdmbca, dmbcafragrances, fragranceshexadecanolactone, hexadecanolactonerfm