A Highly Sensitive and Specific GC-PCI-MS/MS Method for the Analysis of Fluorinated Alkyl Compounds
Posters | 2011 | Agilent TechnologiesInstrumentation
Perfluorinated alkyl compounds (PFCs) and fluorotelomer alcohols (FTOHs) are pervasive in industrial and environmental systems. Their unique physicochemical properties enable wide use in polymer manufacturing, surface treatments and fire-fighting foams. However, environmental persistence, potential for atmospheric and biological degradation to toxic intermediates and global distribution raise concerns about human exposure and ecological impact. Sensitive and selective analytical methods are essential to track fate, transport and transformation pathways of these compounds in complex matrices.
The presented study aimed to develop and validate a highly sensitive and specific gas chromatography method using positive chemical ionization tandem mass spectrometry (GC-PCI-MS/MS) for trace-level determination of twelve fluorotelomer alcohols and two sulfonamidoethanols in heavy bio-solid matrices. A secondary objective evaluated gas chromatography coupled to quadrupole time of flight mass spectrometry (GC-Q-TOF) as an alternative approach to overcome thermal degradation and matrix interferences. The overall goal was to enable robust quantification and improved understanding of degradation pathways in environmental samples.
The analytical workflow combined cold splitless injection, cryogenic focusing and post-column backflush to maximize sensitivity and maintain chromatographic integrity. Bio-solid extracts from wastewater treatment plant biosolids were prepared by methyl tert-butyl ether extraction, lime treatment, centrifugation and solid phase clean-up. Key instrumental parameters included:
GC-PCI-MS/MS achieved detection limits in the low femtogram to sub-picogram on-column range with matrix-matched calibration and signal-to-noise criteria ≥10:1. Precision at 50 pg on column showed relative standard deviations of 2.3–6.9% in biosolid spikes. Post-column backflush effectively removed high-boiling interferences and stabilized retention times within ±0.02 min. GC-Q-TOF demonstrated mass accuracy typically better than 2 ppm and enabled full scan profiling of target analytes with comparable sensitivity. Preliminary method detection limits via Q-TOF ranged from 2 fg to 100 fg on column.
The developed GC-PCI-MS/MS method offers high selectivity through optimized MRM transitions, reduces thermal degradation of labile FTOHs via cold injection and improves throughput with fast backflush cycles. It is well suited for environmental monitoring of PFC precursors in sludge, soil and sediment. The GC-Q-TOF workflow provides a complementary approach for non-target screening and compound confirmation by exact mass.
Ongoing developments may integrate comprehensive two-dimensional GC for enhanced separation of isomeric fluorochemicals and coupling to high-resolution mass spectrometers for suspect screening. Automated sample preparation using dispersive solid phase extraction and microextraction techniques could further streamline analyses. Combined modeling of environmental fate, transformation kinetics and human exposure assessment will expand understanding of PFC lifecycle and inform regulatory strategies.
A robust GC-PCI-MS/MS method has been established for trace determination of fluorotelomer alcohols in complex biosolid matrices, achieving low detection limits, high precision and minimized matrix effects. GC-Q-TOF offers an effective complementary tool for accurate mass analysis and method validation. These advances support environmental monitoring, toxicological studies and remediation efforts for persistent fluorinated pollutants.
GC/MSD, GC/MS/MS, GC/HRMS, GC/Q-TOF
IndustriesEnvironmental
ManufacturerAgilent Technologies
Summary
Significance of the Topic
Perfluorinated alkyl compounds (PFCs) and fluorotelomer alcohols (FTOHs) are pervasive in industrial and environmental systems. Their unique physicochemical properties enable wide use in polymer manufacturing, surface treatments and fire-fighting foams. However, environmental persistence, potential for atmospheric and biological degradation to toxic intermediates and global distribution raise concerns about human exposure and ecological impact. Sensitive and selective analytical methods are essential to track fate, transport and transformation pathways of these compounds in complex matrices.
Study Objectives and Overview
The presented study aimed to develop and validate a highly sensitive and specific gas chromatography method using positive chemical ionization tandem mass spectrometry (GC-PCI-MS/MS) for trace-level determination of twelve fluorotelomer alcohols and two sulfonamidoethanols in heavy bio-solid matrices. A secondary objective evaluated gas chromatography coupled to quadrupole time of flight mass spectrometry (GC-Q-TOF) as an alternative approach to overcome thermal degradation and matrix interferences. The overall goal was to enable robust quantification and improved understanding of degradation pathways in environmental samples.
Methodology and Instrumentation
The analytical workflow combined cold splitless injection, cryogenic focusing and post-column backflush to maximize sensitivity and maintain chromatographic integrity. Bio-solid extracts from wastewater treatment plant biosolids were prepared by methyl tert-butyl ether extraction, lime treatment, centrifugation and solid phase clean-up. Key instrumental parameters included:
- Gas Chromatograph: Dual column configuration with HP-INNOWax fused silica capillaries, pulsed cold splitless inlet, programmable temperature ramp from 45°C to 250°C and purified helium carrier gas.
- MS/MS: Positive chemical ionization with methane reagent gas, optimized collision energies for multiple reaction monitoring (MRM) transitions, nitrogen collision gas and helium quench.
- GC-Q-TOF: Backflush configuration using purged union, 0.7 m restrictor capillary, electronic pressure control and accurate mass acquisition for high resolving power.
Main Results and Discussion
GC-PCI-MS/MS achieved detection limits in the low femtogram to sub-picogram on-column range with matrix-matched calibration and signal-to-noise criteria ≥10:1. Precision at 50 pg on column showed relative standard deviations of 2.3–6.9% in biosolid spikes. Post-column backflush effectively removed high-boiling interferences and stabilized retention times within ±0.02 min. GC-Q-TOF demonstrated mass accuracy typically better than 2 ppm and enabled full scan profiling of target analytes with comparable sensitivity. Preliminary method detection limits via Q-TOF ranged from 2 fg to 100 fg on column.
Benefits and Practical Applications
The developed GC-PCI-MS/MS method offers high selectivity through optimized MRM transitions, reduces thermal degradation of labile FTOHs via cold injection and improves throughput with fast backflush cycles. It is well suited for environmental monitoring of PFC precursors in sludge, soil and sediment. The GC-Q-TOF workflow provides a complementary approach for non-target screening and compound confirmation by exact mass.
Future Trends and Applications
Ongoing developments may integrate comprehensive two-dimensional GC for enhanced separation of isomeric fluorochemicals and coupling to high-resolution mass spectrometers for suspect screening. Automated sample preparation using dispersive solid phase extraction and microextraction techniques could further streamline analyses. Combined modeling of environmental fate, transformation kinetics and human exposure assessment will expand understanding of PFC lifecycle and inform regulatory strategies.
Conclusion
A robust GC-PCI-MS/MS method has been established for trace determination of fluorotelomer alcohols in complex biosolid matrices, achieving low detection limits, high precision and minimized matrix effects. GC-Q-TOF offers an effective complementary tool for accurate mass analysis and method validation. These advances support environmental monitoring, toxicological studies and remediation efforts for persistent fluorinated pollutants.
Reference
- Nakayama SF, Macherone A, Tadele K, Mills MA. Application of GC-MS/MS for volatile fluoroalkyl compound analysis. Dioxin 2010, Marriott Rivercenter, San Antonio, TX; September 12–17, 2010.
- Larsen BS, Stachur P, Szostek B, Bachmura SF, Rowand RC, Prickett KB, Korzeniowski SH, Buck RC. Journal of Chromatography A 1110(1-2):117, 2006.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Analysis of Fluorinated Alkyl Compounds in Bio-solid Matrix by GC/Q-TOF Mass Spectrometry
2011|Agilent Technologies|Posters
Analysis of Fluorinated Alkyl Compounds in Bio-solid Matrix by GC/Q-TOF Mass Spectrometry FPRW 2011 Anthony Macherone2, Tom Doherty2, Shoji F. Nakayama1, 3, Sofia Aronova2, Kidus Tadele1, 4, Marc A. Mills1 1 U.S. Environmental Protection Agency, National Risk Management Research Laboratory;…
Key words
target, targetmefose, mefoseetfose, etfosepfcs, pfcsacronym, acronymdppm, dppmfluorinated, fluorinatedfluorotelomers, fluorotelomersbio, biofacilitated, facilitateddegradation, degradationabund, abundmass, massloss, lossethyl
High Mass Accuracy Provides Enhanced Selectivity for the GC/MS Analysis of Pesticides in Food
2011|Agilent Technologies|Posters
High Mass Accuracy Provides Enhanced Selectivity for the GC/MS Analysis of Pesticidees in Food ASMS 2011 WP 070 Th Thomas P P. D Doherty; h t Phil W Wylie; li Ch Chris i Sandy; S d Bill R Russ; A…
Key words
andd, anddoff, offastragalus, astragalusmass, masschamomile, chamomilefigure, figureeic, eicifi, ifiith, ithmasses, massesregion, regionmasshunter, masshuntertemp, tempcalculator, calculatornoise
Highly Sensitive and Specific GC-MS/MS Method for the Analysis of Boron in Drinking Water and Other Beverages
2011|Agilent Technologies|Posters
Hi hl Sensitive Highly S i i andd Specific S ifi GC GC--MS/MS Method M h d for f the h Analysis A l i off B Boron iin Drinking D i ki Water W andd Other O h Beverages…
Key words
andd, anddboron, boronteb, tebbackflush, backflushmatrixspike, matrixspikemmi, mmimatrix, matrixcal, caloff, offditi, ditimrm, mrmvegetable, vegetableifi, ificollision, collisionturn
Quantitation Target Compound Ion Extraction Matched with Unknowns Analysis Component Perception
2011|Agilent Technologies|Posters
Quantitation Target Compound Ion Extraction Matched with Unknowns Analysis Componnent Perception ASMS 2011 MP23 404 L i TTao, Li S Lei Sun, Vadim V di Kalmeyer, K l Y hi Yoshimasa T Tsunoi, i M Marc Tischler, Ti hl andd…
Key words
target, targetunknowns, unknownsandd, anddtargets, targetsquant, quantnon, nonhits, hitsfigure, figureith, ithwellll, wellllkfl, kfloff, offanalysis, analysishit, hitdeconvolution