GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Use of Calibration Transfer Algorithms on a Mass Spectrometry Based Chemical Sensor - Preliminary Results

Applications | 2003 | GERSTELInstrumentation
GC/MSD, HeadSpace, GC/SQ
Industries
Food & Agriculture
Manufacturer
Agilent Technologies, GERSTEL

Summary

Significance of the Topic


The rapid and reliable classification of volatile samples is essential in food quality control, environmental monitoring, and process analytics. Mass spectrometry-based chemical sensors, or “electronic noses,” offer fast headspace analysis but demand robust calibration models. Frequent instrument adjustments—filament changes, tuning updates, and maintenance—can degrade model accuracy and drive up laboratory costs. Calibration transfer techniques can mitigate these effects by aligning new spectral data with existing models, reducing downtime and resource expenditure.

Objectives and Study Overview


This preliminary investigation evaluates calibration transfer algorithms on a GERSTEL Headspace ChemSensor coupled to an Agilent 5973N mass selective detector. Over ten weeks, three perturbations were introduced: (a) tuning algorithm changes, (b) filament replacements, and (c) ion source maintenance. Three data sets—camphor solutions, citrus oil headspaces, and limonene standards—were collected to assess classification performance under varying conditions and to compare chemometric approaches: k-nearest neighbors (KNN), SIMCA, and partial least squares (PLS) with direct standardization transfer.

Methodology and Instrumentation


Samples were prepared and headspace-analyzed under controlled temperature and equilibration times. Chemometric models were built on reference data and used to predict perturbed measurements. Transfer of calibration (TOC) was performed via direct standardization, using two to three transfer samples per class or concentration level.

Instrumentation Used


  • GERSTEL Headspace ChemSensor
  • Agilent 5973N Mass Selective Detector
  • PFTBA tuning compound with standard, BFB, and Autotune algorithms

Main Results and Discussion


Tuning study with camphor revealed minor ion abundance shifts among Autotune, BFB, and standard spectra tunes. Normalization aligned spectra but only KNN achieved 100% classification accuracy without transfer; SIMCA improved from 23–40% to 93–99% correct predictions using TOC.

Filament replacement experiments on citrus oils showed overall signal decrease with new filaments. Post-normalization KNN again delivered perfect classification. SIMCA accuracy rose from 50% to 75–78% with two to three transfer samples.

Limonene quantitation before and after ion source cleaning exhibited slight spectral changes. KNN maintained 100% class assignment. PLS regression models achieved a standard error of prediction (SEP) of 38 µg, which improved marginally to 37 µg using TOC. Hierarchical clustering confirmed reduced variance after source maintenance.

Benefits and Practical Applications


  • Minimized need for full recalibration following routine maintenance.
  • Maintained classification and quantitative accuracy with minimal transfer samples.
  • Reduced laboratory time and operational costs in QA/QC workflows.

Future Trends and Potential Applications


Extending calibration transfer to complex multi-sensor arrays, integrating adaptive algorithms for real-time drift correction, and exploring machine learning–based transfer approaches. Further studies should cover diverse matrices, longer monitoring periods, and automated transfer sample selection to enhance field deployability.

Conclusion


Calibration transfer via direct standardization effectively compensates for hardware-induced spectral variations in mass spectrometry–based chemical sensors. KNN classification proves inherently robust, while SIMCA and PLS models benefit significantly from transfer adjustments. Implementing these strategies streamlines maintenance cycles, sustains model reliability, and supports cost-effective routine analyses.

References


  • [1] Agilent Technologies. ChemStation Enhanced Data Analysis Software Help: Tuning the MSD (G1701CA, vC.00.00).
  • [2] Infometrix, Inc. Pirouette Chemometrics Software Help Menu (v3.11).

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Use of a Mass Spectral Based Chemical Sensor to Discriminate Food and Beverage Samples: Olive Oils and Wine as Examples
AppNote 1/2004 Use of a Mass Spectral Based Chemical Sensor to Discriminate Food and Beverage Samples: Olive Oils and Wine as Examples Vanessa R. Kinton, Jacqueline A. Whitecavage Gerstel, Inc., 701 Digital Drive, Suite J, Linthicum, MD 21090, USA Arnd…
Key words
chemsensor, chemsensortca, tcaolive, oliveoils, oilsabundance, abundancegerstel, gerstelunknown, unknowndegassed, degassedknn, knnpure, pureppb, ppbwine, winefaster, fasterppt, pptwere
Analysis of Packaging Materials using a Mass Spectral Based Chemical Sensor
AppNote 2/2004 Analysis of Packaging Materials using a Mass Spectral Based Chemical Sensor Vanessa R. Kinton Gerstel, Inc., Caton Research Center, 1510 Caton Center Drive, Suite H, Baltimore, MD 21227, USA Arnd C. Heiden, Carlos Gil Gerstel GmbH & Co.KG,…
Key words
chemsensor, chemsensorpackaging, packagingtpgda, tpgdagerstel, gerstelclassify, classifysensor, sensorsamples, samplesdetect, detectodor, odorincubation, incubationcartons, cartonsclassification, classificationobjective, objectivemilk, milknearest
Wine Discrimination using a Mass Spectral Based Chemical Sensor
AppNote 2/2003 Wine Discrimination using a Mass Spectral Based Chemical Sensor Vanessa R. Kinton, Edward A. Pfannkoch Gerstel, Inc., Caton Research Center, 1510 Caton Center Drive, Suite H, Baltimore, MD 21227, USA M. Abdul Mabud, Sumer M. Dugar Alcohol &…
Key words
wines, winesvarietal, varietalabundance, abundancemerlot, merlotwine, winechemsensor, chemsensorpure, puregerstel, gerstelheadspace, headspaceobtained, obtainedmultivariate, multivariatepca, pcaprincipal, principalcabernet, cabernetfingerprint
Fast Analysis of Beverages using a Mass Spectral Based Chemical Sensor
AppNote 4/2003 Fast Analysis of Beverages using a Mass Spectral Based Chemical Sensor Vanessa R. Kinton, Robert J. Collins Gerstel, Inc., Caton Research Center, 1510 Caton Center Drive, Suite H, Baltimore, MD 21227, USA Bita Kolahgar Gerstel GmbH & Co.…
Key words
koenig, koenigpilsener, pilsenerblend, blendgerstel, gerstelmerlot, merlotabundance, abundancechemsensor, chemsensorjuice, juiceorange, orangesamples, sampleswine, winediacetyl, diacetylcabernet, cabernetmodel, modelprojection
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike