Purity Test of Calcium Polystyrene Sulfonate, with reference to the Japanese Pharmacopoeia, 16th Edition - Comparisons of Chromosorb Series and Uniport Series of Siliceous Soil Support
Applications | | GL SciencesInstrumentation
Calcium polystyrene sulfonate is a cardiovascular agent used to reduce elevated blood potassium levels in hyperkalemia. Ensuring the absence of residual monomers such as styrene is critical for patient safety and therapeutic efficacy. Compliance with pharmacopeial purity standards via reliable analytical methods underpins quality assurance in pharmaceutical production.
This study evaluates and compares two siliceous earth GC carriers, Chromosorb WAW DMCS and Uniport HP, for their performance in the Japanese Pharmacopoeia 16th edition purity test for calcium polystyrene sulfonate. The primary objectives are to assess system suitability parameters, chromatographic behavior, and repeatability using styrene as the test impurity.
The prescribed GC method employs direct injection of analyte solutions in acetone. Key conditions include:
System performance with 10 µg/mL styrene standard:
Emerging developments may include ultra-fast GC columns to reduce analysis time, coupling with mass spectrometric detection for comprehensive impurity profiling, novel inert support chemistries to further improve chromatographic performance, and automated sample preparation systems to enhance throughput.
Both Chromosorb WAW DMCS and Uniport HP carriers satisfy the Japanese Pharmacopeia 16th edition purity test for calcium polystyrene sulfonate, delivering high theoretical plate counts, optimal peak symmetry, and low variability. This validates their suitability for pharmaceutical quality control applications.
Japanese Pharmacopoeia, 16th Edition, Purity Test for Calcium Polystyrene Sulfonate
GC
IndustriesPharma & Biopharma
ManufacturerGL Sciences
Summary
Significance of Topic
Calcium polystyrene sulfonate is a cardiovascular agent used to reduce elevated blood potassium levels in hyperkalemia. Ensuring the absence of residual monomers such as styrene is critical for patient safety and therapeutic efficacy. Compliance with pharmacopeial purity standards via reliable analytical methods underpins quality assurance in pharmaceutical production.
Study Objectives and Overview
This study evaluates and compares two siliceous earth GC carriers, Chromosorb WAW DMCS and Uniport HP, for their performance in the Japanese Pharmacopoeia 16th edition purity test for calcium polystyrene sulfonate. The primary objectives are to assess system suitability parameters, chromatographic behavior, and repeatability using styrene as the test impurity.
Methodology
The prescribed GC method employs direct injection of analyte solutions in acetone. Key conditions include:
- Stationary phase: 15% PEG 20M coated on either Chromosorb WAW DMCS or Uniport HP (80/100 mesh), packed in a 2 m × 3 mm I.D. stainless steel column
- Oven temperature: 90 °C
- Injector temperature: 250 °C; injection volume: 5 µL
- Detector: Flame ionization detector (FID) at 250 °C, auto range
- Carrier gas: Nitrogen at 180 kPa
- Analytes: Styrene standards at 1 µg/mL and 10 µg/mL, plus blank runs
Instrumentation
- Gas chromatograph with FID
- Chromosorb WAW DMCS and Uniport HP diatomaceous earth supports treated by washing, acid treatment, and silanization
- Precision injector and temperature-controlled oven
- Nitrogen supply system for carrier gas
Main Results and Discussion
System performance with 10 µg/mL styrene standard:
- Chromosorb WAW DMCS: 3 502 theoretical plates, symmetry factor 1.05
- Uniport HP: 3 715 theoretical plates, symmetry factor 1.05
- Chromosorb WAW DMCS: RSD 2.58%
- Uniport HP: RSD 2.74%
Benefits and Practical Applications
- Reliable separation and quantification of styrene ensure robust purity checks for calcium polystyrene sulfonate.
- Uniport HP’s advanced silanization enhances inertness, minimizing peak tailing and adsorption effects.
- The method can be implemented in routine pharmaceutical QC for similar polymeric drug substances.
Future Trends and Potential Applications
Emerging developments may include ultra-fast GC columns to reduce analysis time, coupling with mass spectrometric detection for comprehensive impurity profiling, novel inert support chemistries to further improve chromatographic performance, and automated sample preparation systems to enhance throughput.
Conclusion
Both Chromosorb WAW DMCS and Uniport HP carriers satisfy the Japanese Pharmacopeia 16th edition purity test for calcium polystyrene sulfonate, delivering high theoretical plate counts, optimal peak symmetry, and low variability. This validates their suitability for pharmaceutical quality control applications.
Reference
Japanese Pharmacopoeia, 16th Edition, Purity Test for Calcium Polystyrene Sulfonate
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Supelco Columns for USP Methods
2014|Merck|Posters
Supelco Columns for USP Methods The official pharmaceutical analysis monographs in the United States Pharmacopeia (USP) detail the methods used by pharmaceutical manufacturers for quality control of bulk drug substances and dosage form preparations. Each method specifies a particular high…
Key words
supelcosil, supelcosilglycol, glycolchromosorb, chromosorbhayesep, hayesepastec, asteccopolymer, copolymerdivinylbenzene, divinylbenzenesuccinate, succinateascentis, ascentissupelcogel, supelcogelporapak, porapakresin, resinbonded, bondedadipate, adipatestyrene
Purity Test and Fatty Acid Content Ratio Test of Polysorbate 80 - Supplement II to the Japanese Pharmacopoeia, 16th Edition
|GL Sciences|Applications
GC Technical Note GT086 GL Sciences Inc. Purity Test and Fatty Acid Content Ratio Test of Polysorbate 80 - Supplement II to the Japanese Pharmacopoeia, 16th Edition A harmonized test was agreed for Polysorbate 80 in the three pharmacopoeias of…
Key words
uvolt, uvoltmethyl, methyltest, testfatty, fattysciences, sciencesspecified, specifiedmyristate, myristateanalyte, analytesuitability, suitabilityadvice, advicemin, minconditions, conditionsheptane, heptanetime, timesystem
Purity Test of Sucralose, Pharmaceutical Excipients Standard 2018
|GL Sciences|Applications
GC Technical Note Purity Test of Sucralose, Pharmaceutical Excipients Standard 2018 GT115 GL Sciences Inc. Sucralose is an artificial sweetener used as an excipient in pharmaceuticals. The purity test for sucralose listed in the Pharmaceutical Excipients Standard 2013 original required…
Key words
standard, standardstock, stockuvolts, uvoltssucralose, sucraloseinternal, internalheadspace, headspacesciences, sciencestest, testtechnical, technicalamended, amendedfid, fidsolution, solutionmethanol, methanolnote, noteautosampler
Analysis of memantine hydrochloride in accordance with the USP
|GL Sciences|Applications
GC Technical Note Analysis of memantine hydrochloride in accordance with the USP GT101 GL Sciences Inc. Memantine hydrochloride is used to treat moderate to severe dementia (Alzheimer‘s type). In this application note analysis was made in accordance with the United…
Key words
uvolts, uvoltsmin, minsciences, sciencestime, timetechnical, technicalmemantine, memantineconditions, conditionsnote, notestandard, standardrelative, relativedistributors, distributorshydrochloride, hydrochloridecarrier, carrieranalyte, analyteaccordance