Analysis of Distilled Spirits Using an Agilent 8890 Gas Chromatograph System
Applications | 2018 | Agilent TechnologiesInstrumentation
Analysis of distilled spirits by gas chromatography is critical for maintaining consistent flavor profiles and product safety in the beverage industry. High water content poses column durability challenges and increases maintenance, making robust analytical workflows essential.
This study demonstrates the capability of an Agilent 8890 GC system with a J and W DB WAX Ultra Inert column to perform repeated injections of neat bourbon whiskey with high precision and minimal maintenance.
The workflow enables high throughput routine analysis of distilled spirits with minimal downtime for maintenance. It supports QA QC operations in distilleries and laboratories analyzing aqueous samples with complex matrices.
Integration with mass spectrometry for compound identification and quantitation automation can further enhance analysis depth. Emerging micro fast columns and greener carrier gas approaches promise even faster run times and lower environmental impact.
The Agilent 8890 GC and J and W DB WAX Ultra Inert column deliver robust reproducible analysis of water rich spirits. Method translation and use of hydrogen carrier gas significantly improve throughput and reduce operational costs.
GC
IndustriesFood & Agriculture
ManufacturerAgilent Technologies
Summary
Importance of the Topic
Analysis of distilled spirits by gas chromatography is critical for maintaining consistent flavor profiles and product safety in the beverage industry. High water content poses column durability challenges and increases maintenance, making robust analytical workflows essential.
Study Goals and Overview
This study demonstrates the capability of an Agilent 8890 GC system with a J and W DB WAX Ultra Inert column to perform repeated injections of neat bourbon whiskey with high precision and minimal maintenance.
Methods and Instrumentation
- GC system Agilent 8890 with flame ionization detector and split inlet in split mode
- Carrier gas helium at constant flow of 2.0 mL per minute; hydrogen in alternative mode at 1.2 mL per minute
- J and W DB WAX UI columns 30 m x 0.25 mm x 0.25 um and 20 m x 0.18 mm x 0.18 um
- Injection of neat Woodford Reserve bourbon whiskey in 2 mL vials using 1 uL sampling volume
- Oven temperature program from 40 deg C to 200 deg C yielding analysis times of 26 19 and 12.8 minutes
Main Results and Discussion
- Chromatograms show stable retention time and peak shape for key analytes including ethyl acetate methanol ethanol propanol butanol and acetic acid over 400 injections
- Use of Ultra Inert flowpath preserves column performance against water rich samples without frequent maintenance
- Method translation to smaller id column reduced run time from 26 to 19 minutes with helium and to 12.8 minutes with hydrogen while maintaining peak quality
Benefits and Practical Applications
The workflow enables high throughput routine analysis of distilled spirits with minimal downtime for maintenance. It supports QA QC operations in distilleries and laboratories analyzing aqueous samples with complex matrices.
Future Trends and Potential Applications
Integration with mass spectrometry for compound identification and quantitation automation can further enhance analysis depth. Emerging micro fast columns and greener carrier gas approaches promise even faster run times and lower environmental impact.
Conclusion
The Agilent 8890 GC and J and W DB WAX Ultra Inert column deliver robust reproducible analysis of water rich spirits. Method translation and use of hydrogen carrier gas significantly improve throughput and reduce operational costs.
Reference
- Analysis of Distilled Spirits Using an Agilent J and W DB WAX Ultra Inert Capillary GC Column Application Note 5991 6638EN 2016
- Ng L Lafontaine P Harnois J J Chromatogr A 873 1 29 38 2000
- MacNamara K Lee M Robbat Jr A J Chromatogr A 1217 1 136 142 2010
- Fitzgerald G et al J Chromatogr A 896 1 2 351 359 2000
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Analysis of Distilled Spirits Using an Agilent J&W DB-WAX Ultra Inert Capillary GC Column
2016|Agilent Technologies|Applications
Analysis of Distilled Spirits Using an Agilent J&W DB-WAX Ultra Inert Capillary GC Column Application Note Flavors and Fragrances, Food Authors Abstract Kenneth Lynam The Agilent J&W DB-WAX Ultra Inert GC column has excellent stability for Agilent Technologies, Inc distilled…
Key words
wax, waxspirits, spiritsflavor, flavorinert, inertcolumn, columninertness, inertnessquantification, quantificationalcohol, alcoholexcellent, excellentdistilled, distilledpeak, peakagilent, agilentstability, stabilityparameter, parametervalue
Agilent J&W DB-WAX Ultra Inert GC columns - Increase Your Analytical Confidence For Challenging Polar Compounds
2019|Agilent Technologies|Brochures and specifications
Increase Your Analytical Confidence For Challenging Polar Compounds Agilent J&W DB-WAX Ultra Inert GC columns Now You Can Achieve Better Peak Shape and Reproducibility for Challenging Polar Compounds GC columns with polyethylene glycol (PEG) stationary phases are commonly used for…
Key words
wax, waxinert, inertultra, ultrainertness, inertnessagilent, agilentltra, ltracolumn, columntightening, tighteningcolumns, columnsnut, nutmau, maupolar, polarplus, plusglycol, glycolultimetal
Analysis of Some Alcohols, Aldehydes, and Esters in Distilled Spirits with the Agilent 8860 Gas Chromatograph
2019|Agilent Technologies|Applications
Application Note Spirits Analysis Analysis of Some Alcohols, Aldehydes, and Esters in Distilled Spirits with the Agilent 8860 Gas Chromatograph Author Youjuan Zhang Agilent Technologies (Shanghai) Co. Ltd. Shanghai 200131 P. R. China Abstract The Agilent 8860 GC configured with…
Key words
liquor, liquorspirits, spiritschinese, chineseflavor, flavorethyl, ethylratio, ratiowere, wereisovaleraldehyde, isovaleraldehydeacetal, acetalhexanoate, hexanoateethanol, ethanolstandard, standarddistilled, distilledfid, fidacetate
WAX Column Technology Update and Recent Applications
2021|Agilent Technologies|Presentations
WAX Column Technology Update and Recent Applications Gustavo Serrano Izaguirre, Ph.D., Global Product Manager – GC Columns 1 March 29, 2021 DE44274.5728240741 WAX Columns • Also referred to as Polyethylene Glycol (PEG) columns • Used to analyze polar compounds •…
Key words
wax, waxconfidentiality, confidentialitytitle, titlelabel, labelheavywax, heavywaxfatwax, fatwaxacid, acidinert, inertacids, acidsultra, ultracompetitor, competitorinertness, inertnessdha, dhacolumn, columnxylene