Agilent J&W DB-WAX Ultra Inert GC columns - Increase Your Analytical Confidence For Challenging Polar Compounds
Brochures and specifications | 2019 | Agilent TechnologiesInstrumentation
The reliable analysis of polar compounds by gas chromatography is critical across food, flavor, fragrance, environmental, pharmaceutical, and industrial quality control laboratories. Traditional PEG (WAX) stationary phases often suffer from active site adsorption, leading to poor peak shape, inconsistent retention times, and increased repeat analyses. The development of Ultra Inert (UI) DB-WAX columns addresses these challenges by minimizing flow-path activity and enhancing method robustness.
This work evaluates the performance of Agilent J&W DB-WAX Ultra Inert GC columns relative to standard WAX and competitive brands. Key goals include demonstrating:
The UI columns feature a Durabond PEG stationary phase with proprietary deactivation and processing. Inertness was probed using demanding test mixes containing polar acids, alcohols, glycols, and flavor probes. Comparative studies included:
Instrumentation employed varied by application, typically:
Inertness testing revealed that DB-WAX UI columns deliver superior peak shapes and reproducibility for active analytes such as propionic acid, ethyl maltol, glycols, and free fatty acids. Key findings include:
Implementing DB-WAX UI columns enables laboratories to:
Advancements in column inertness and high-temperature PEG phases are expected to further enhance trace-level detection of active compounds. Integration with automated sample preparation, capillary flow technology for backflush, and advanced MS detectors will expand capabilities in metabolomics, petrochemical QA/QC, and regulatory laboratories. Ongoing development of ultra-inert hardware throughout the GC flow path promises end-to-end activity control for the most demanding analyses.
Agilent J&W DB-WAX Ultra Inert GC columns significantly improve analytical confidence for polar and active compounds, delivering exceptional peak shape, inertness, and method compatibility. Their adoption streamlines workflows, lowers operational costs, and supports robust quantitative and qualitative results across diverse applications.
GC columns, Consumables
IndustriesManufacturerAgilent Technologies
Summary
Significance of the Topic
The reliable analysis of polar compounds by gas chromatography is critical across food, flavor, fragrance, environmental, pharmaceutical, and industrial quality control laboratories. Traditional PEG (WAX) stationary phases often suffer from active site adsorption, leading to poor peak shape, inconsistent retention times, and increased repeat analyses. The development of Ultra Inert (UI) DB-WAX columns addresses these challenges by minimizing flow-path activity and enhancing method robustness.
Study Objectives and Overview
This work evaluates the performance of Agilent J&W DB-WAX Ultra Inert GC columns relative to standard WAX and competitive brands. Key goals include demonstrating:
- Improved inertness and peak shapes for challenging polar analytes
- Reproducibility of column-to-column and temperature-cycling stability
- Compatibility with existing DB-WAX methods and compound libraries
Methodology and Used Instrumentation
The UI columns feature a Durabond PEG stationary phase with proprietary deactivation and processing. Inertness was probed using demanding test mixes containing polar acids, alcohols, glycols, and flavor probes. Comparative studies included:
- DB-WAX UI vs. standard DB-WAX and competitor WAX columns
- Temperature cycling up to 250 °C over extended time
- Trace-level and complex matrix analyses (spirits, toothpaste, essential oils, BTEX, FAMEs)
Instrumentation employed varied by application, typically:
- Agilent 7890/7800 series GC with 5977A MSD or FID detection
- 7683B autosampler, split/splitless inlet (250 °C) with Ultra Inert liner and gold seal
- Carrier gases: hydrogen (41 cm/s) or helium (constant flow)
- Oven programs from isothermal 130 °C to temperature ramps reaching 290 °C for high-temperature testing
Main Results and Discussion
Inertness testing revealed that DB-WAX UI columns deliver superior peak shapes and reproducibility for active analytes such as propionic acid, ethyl maltol, glycols, and free fatty acids. Key findings include:
- Consistent inertness out of the box, eliminating prequalification
- Minimal retention time shifts after 50 h at 250 °C versus competitor WAX columns
- Enhanced responses for trace diethylene and ethylene glycol in toothpaste matrices
- Stable, aqueous injections and robust performance for whiskey volatile profiling
- Identical selectivity to standard DB-WAX for FAMEs, BTEX, and essential oil components, enabling straightforward method transfer
Benefits and Practical Applications
Implementing DB-WAX UI columns enables laboratories to:
- Reduce troubleshooting and reruns due to adsorption effects
- Extend column lifetime and lower per-analysis costs through temperature cycling resistance
- Easily upgrade existing DB-WAX methods without revalidation of selectivity or libraries
- Broadly apply a single column type across food and beverage QC, environmental solvent screening, fragrance profiling, and forensic ethanol/blood alcohol analysis
Future Trends and Potential Applications
Advancements in column inertness and high-temperature PEG phases are expected to further enhance trace-level detection of active compounds. Integration with automated sample preparation, capillary flow technology for backflush, and advanced MS detectors will expand capabilities in metabolomics, petrochemical QA/QC, and regulatory laboratories. Ongoing development of ultra-inert hardware throughout the GC flow path promises end-to-end activity control for the most demanding analyses.
Conclusion
Agilent J&W DB-WAX Ultra Inert GC columns significantly improve analytical confidence for polar and active compounds, delivering exceptional peak shape, inertness, and method compatibility. Their adoption streamlines workflows, lowers operational costs, and supports robust quantitative and qualitative results across diverse applications.
References
- Agilent Technologies. A New PEG GC Column with Improved Inertness Reliability and Column Lifetime. Application Note 5991-6683EN.
- Agilent Technologies. Analysis of Glycols in Toothpaste Using Agilent J&W DB-WAX Ultra Inert Capillary GC Column. Application Note 5991-6637EN.
- Agilent Technologies. Analysis of Distilled Spirits Using Agilent J&W DB-WAX Ultra Inert Capillary GC Column. Application Note 5991-6638EN.
- Agilent Technologies. Analysis of Lavender Essential Oil by Agilent J&W DB-WAX Ultra Inert Capillary GC Columns. Application Note 5991-6635EN.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Detect Every Peak and Minimize Degradative Buildup in Your GC Flow Path - Agilent Inert Flow Path solutions
2020|Agilent Technologies|Brochures and specifications
Detect Every Peak and Minimize Degradative Buildup in Your GC Flow Path Agilent Inert Flow Path solutions Ensuring an Inert Flow Path from Injection Through Detection Is Critical—and Now, Easy to Achieve As regulatory agencies drive limits of detection lower…
Key words
inert, inertagilent, agilentultra, ultrapath, pathliners, linersultimetal, ultimetalplus, plusflow, flowinlet, inletinertness, inertnessdeactivation, deactivationyour, yourmetal, metalflexible, flexiblegold
Agilent J&W DB-WAX Ultra Inert GC columns
2016|Agilent Technologies|Others
INCREASE YOUR ANALYTICAL CONFIDENCE FOR POLAR COMPOUNDS Agilent J&W DB-WAX Ultra Inert GC columns For increasingly active polar analytes, you cannot afford adsorption caused by flow path activity. Having to repeat or verify suspect analyses wastes resources, hinders productivity, and…
Key words
wax, waxinert, inertacid, acidultra, ultrapropionic, propionicshape, shapecolumns, columnsinertness, inertnessexcellent, excellentyour, yourdeliver, deliverpath, pathmix, mixevery, everydodecanoate
WAX Column Technology Update
2018|Agilent Technologies|Presentations
WAX Column Technology Update Mark Sinnott August 14, 2018 1 August 14, 2018 Agilent J&W DB-HeavyWAX WAX Column Update • What is a WAX column? • Traditional WAX Phases • • • • • • 2 DB-WAX HP-INNOWAX VF-WAX MS…
Key words
heavywax, heavywaxwax, waxfatwax, fatwaxagilent, agilentcolumn, columnacids, acidsinert, inertcompetitor, competitordha, dhaacid, acidfame, famebleed, bleedffap, ffapultra, ultratraditional
GC Analysis of Glycols in Toothpaste
2016|Agilent Technologies|Applications
GC Analysis of Glycols in Toothpaste Using Agilent J&W DB-Wax Ultra Inert Capillary GC Columns Application Note Flavors and Fragrances, Consumer Products Author Abstract Yun Zou This application note demonstrates the excellent inertness performance of Agilent Technologies, Ltd an Agilent…
Key words
wax, waxdeg, degtoothpaste, toothpasteagilent, agilentglycerin, glycerininert, inertcolumn, columnultra, ultrainertness, inertnessmin, minglycol, glycolglycols, glycolstime, timestandards, standardscolumns