Agilent Inert Flow Path Solutions - Quick Reference Guide
Guides | 2021 | Agilent TechnologiesInstrumentation
Maintaining an inert flow path in gas chromatography is essential for trace-level analysis of active and thermally labile compounds. Inert surfaces prevent adsorption, decomposition, and carryover, ensuring accurate quantitation and reliable retention times. Agilent’s Inert Flow Path components are engineered to deliver high reproducibility, low bleed, and robust performance in demanding analytical applications.
This guide presents Agilent’s portfolio of inert inlet liners, seals, ferrules, ferrule washers, upgrade kits, and J&W Ultra Inert GC columns. It aims to help laboratories optimize their GC systems (7890B, 8890, 8860) for maximal inertness and minimal analyte interaction.
Agilent Inert Flow Path is built around four main component categories:
Agilent’s inert components collectively reduce active sites, leading to improved peak symmetry, higher signal-to-noise ratios, and enhanced repeatability. The touchless packaging for liners and ferrules preserves surface inertness prior to installation. The UltiMetal Plus treatments and gold plating minimize metal-induced catalytic effects. When retrofitted or specified at system purchase, these components deliver consistent performance across a broad range of analytes, from pesticides to volatile organics.
Implementing an inert flow path supports:
Advances in surface coatings and additive manufacturing may yield even more inert pathways. Integration of smart keys and digital diagnostics will simplify maintenance tracking. Emerging applications—such as real-time process monitoring and micro-GC—will benefit from miniaturized inert flow components. Ongoing development of low-bleed, high-temperature phases will expand the scope of GC analyses into novel compound classes.
Agilent’s Inert Flow Path solutions offer a comprehensive approach to minimizing analyte–surface interactions in gas chromatography. By selecting appropriate liners, seals, ferrules, and columns, laboratories can achieve superior sensitivity, reproducibility, and system uptime. Strategic upgrades and best practices ensure sustained performance for a wide spectrum of analytical challenges.
None provided in source document.
Consumables
IndustriesManufacturerAgilent Technologies
Summary
Importance of Inert Flow Path Solutions
Maintaining an inert flow path in gas chromatography is essential for trace-level analysis of active and thermally labile compounds. Inert surfaces prevent adsorption, decomposition, and carryover, ensuring accurate quantitation and reliable retention times. Agilent’s Inert Flow Path components are engineered to deliver high reproducibility, low bleed, and robust performance in demanding analytical applications.
Objectives and Overview
This guide presents Agilent’s portfolio of inert inlet liners, seals, ferrules, ferrule washers, upgrade kits, and J&W Ultra Inert GC columns. It aims to help laboratories optimize their GC systems (7890B, 8890, 8860) for maximal inertness and minimal analyte interaction.
Methodology and Used Instrumentation
Agilent Inert Flow Path is built around four main component categories:
- Ultra Inert Inlet Liners: Single- and double-taper liners, wool-packed, fritted, and dimpled designs for split and splitless inlets, including special liners for headspace and SPME.
- Seals and Washers: Gold seals paired with nonstick O-rings to ensure leak-free connections and minimal surface activity.
- Flexible Metal Ferrules: UltiMetal Plus and gold-plated ferrules in various internal diameters, sized to match 0.10–0.53 mm fused silica tubing, eliminating column breakage and reactive sites.
- GC Columns: J&W Ultra Inert phases (DB-1ms, DB-5ms, DB-35ms, HP-1ms, DB-WAX, DB-FATWAX, DB-BAC, DB-624, DB-UI 8270D) engineered for low bleed, wide temperature range, and enhanced inertness.
Main Findings and Discussion
Agilent’s inert components collectively reduce active sites, leading to improved peak symmetry, higher signal-to-noise ratios, and enhanced repeatability. The touchless packaging for liners and ferrules preserves surface inertness prior to installation. The UltiMetal Plus treatments and gold plating minimize metal-induced catalytic effects. When retrofitted or specified at system purchase, these components deliver consistent performance across a broad range of analytes, from pesticides to volatile organics.
Benefits and Practical Applications
Implementing an inert flow path supports:
- Trace-level quantitation in environmental, petrochemical, and forensic analyses.
- Analysis of reactive or polar compounds without peak tailing or loss.
- Routine QA/QC in pharmaceutical and food testing with high uptime.
- Seamless integration into 7890B, 8890, and 8860 GC systems, including retrofit kits (G3970A) and accessory options.
Future Trends and Opportunities
Advances in surface coatings and additive manufacturing may yield even more inert pathways. Integration of smart keys and digital diagnostics will simplify maintenance tracking. Emerging applications—such as real-time process monitoring and micro-GC—will benefit from miniaturized inert flow components. Ongoing development of low-bleed, high-temperature phases will expand the scope of GC analyses into novel compound classes.
Conclusion
Agilent’s Inert Flow Path solutions offer a comprehensive approach to minimizing analyte–surface interactions in gas chromatography. By selecting appropriate liners, seals, ferrules, and columns, laboratories can achieve superior sensitivity, reproducibility, and system uptime. Strategic upgrades and best practices ensure sustained performance for a wide spectrum of analytical challenges.
References
None provided in source document.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Detect Every Peak and Minimize Degradative Buildup in Your GC Flow Path - Agilent Inert Flow Path solutions
2020|Agilent Technologies|Brochures and specifications
Detect Every Peak and Minimize Degradative Buildup in Your GC Flow Path Agilent Inert Flow Path solutions Ensuring an Inert Flow Path from Injection Through Detection Is Critical—and Now, Easy to Achieve As regulatory agencies drive limits of detection lower…
Key words
inert, inertagilent, agilentultra, ultrapath, pathliners, linersultimetal, ultimetalplus, plusflow, flowinlet, inletinertness, inertnessdeactivation, deactivationyour, yourmetal, metalflexible, flexiblegold
Optimizing the performance of your Shimadzu gc with agilent columns & Supplies
2015|Agilent Technologies|Brochures and specifications
Optimizing the perfOrmance Of yOur Shimadzu gc with agilent cOlumnS & SupplieS Agilent gC SupplieS for ShimAdzu table of contents introduction...........................................................................3 improve the performance of your Shimadzu Qp2010 with agilent gc Supplies..................4 inert flow path components .............................................5 Ultra Inert Inlet…
Key words
ptfe, ptfeshimadzu, shimadzuagilent, agilentsilicone, siliconepolypropylene, polypropyleneunit, unitsepta, septacolumns, columnsfilm, filmlength, lengthdescription, descriptiontemp, tempitalicized, italicizedclosures, closuresinert
GC AND GC/MS - Your Essential Resource for Columns & Supplies
2016|Agilent Technologies|Brochures and specifications
Buy online: www.agilent.com/chem/store Contact us: www.agilent.com/chem/contactus THE ESSENTIAL CHROMATOGRAPHY & SPECTROSCOPY CATALOG For more information This information is subject to change without notice. © Agilent Technologies, Inc. 2014 Printed in Canada October XX, 2014 5991-5213EN GC AND GC/MS Your Essential…
Key words
agilent, agilentsupplies, suppliescolumns, columnslength, lengthparts, partscrosslab, crosslabcolumn, columnfilm, filmsuggested, suggesteddescription, descriptionrinsable, rinsableoem, oemultimetal, ultimetaltips, tipsnut
Agilent GC AND GC/MS Columns Catalog
2016|Agilent Technologies|Others
Buy online: www.agilent.com/chem/store Contact us: www.agilent.com/chem/contactus THE ESSENTIAL CHROMATOGRAPHY & SPECTROSCOPY CATALOG For more information This information is subject to change without notice. © Agilent Technologies, Inc. 2016 Printed in Canada March 8, 2016 5991-5213EN GC AND GC/MS Your Essential…
Key words
agilent, agilentcolumns, columnslength, lengthfilm, filmrinsable, rinsableultimetal, ultimetalltm, ltmitalicized, italicizedcolumn, columnbonded, bondedchromosorb, chromosorbtest, testdescriptions, descriptionslinked, linkedmesh