Others | 2016 | Agilent TechnologiesInstrumentation
GC columns, Consumables
Industries
Manufacturer
Agilent Technologies

Summary

Significance of the Topic


Reliable analysis of polar compounds is critical across food quality, environmental monitoring and industrial quality control. Adsorption in the GC flow path leads to peak tailing, loss of sensitivity and repeated analyses, impacting productivity, cost and data integrity.

Objectives and Study Overview


This application note evaluates the performance of Agilent J&W DB-WAX Ultra Inert GC columns for challenging polar analytes. Key goals include comparing inertness and longevity against standard WAX phases, illustrating peak shape improvements and demonstrating workflow benefits.

Methodology and Instrumentation


Gas chromatographic tests employed DB-WAX Ultra Inert columns installed in an Agilent Inert Flow Path GC/MS system. Inertness was assessed using a nine-component QC test mix containing strong probe analytes such as decanal, propionic acid, 2-ethylhexanoic acid and ethyl maltol. Thermal exposure at 250 °C extended up to 50 hours evaluated long-term adsorption effects. A separate free fatty acid mixture was analyzed to examine acidic compound peak shapes.

Main Results and Discussion


Even after 50 hours at 250 °C, Ultra Inert columns maintained sharp, symmetric peaks with minimal response loss, whereas competitive columns showed significant tailing and reduced signals. Retention time stability remained high, with reproducibility of peak areas and detection limits preserved over repeated temperature cycles. Analysis of free fatty acids confirmed excellent resolution and reproducible quantitation without the need for a specialized FFAP phase.

Benefits and Practical Applications


  • Reduced troubleshooting and reruns: Enhanced inertness delivers reliable peak shape and consistent reproducibility for polar and acidic analytes.
  • Lower operational costs: Extended column lifetime withstands repeated temperature cycles, reducing replacement frequency.
  • Out-of-the-box performance: Prequalified inertness ensures consistent results without individual column qualification.
  • Seamless method transfer: Identical selectivity to standard DB-WAX phases allows easy upgrade without library redevelopment.

Future Trends and Opportunities


Demand for even higher inertness will drive further optimization of flow path materials and coatings. Integration with automated sampling and data analytics will enhance throughput. Miniaturized and high-throughput GC platforms paired with ultra inert columns will expand applications in metabolomics, lipidomics and trace level contaminant analysis.

Conclusion


Agilent J&W DB-WAX Ultra Inert GC columns significantly increase analytical confidence for polar compounds by minimizing adsorption, improving peak shape stability and extending column life. Laboratories benefit from reduced downtime, lower costs and straightforward method implementation.

References


  • No literature references were provided in the source document

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Agilent J&W DB-WAX Ultra Inert GC columns - Increase Your Analytical Confidence For Challenging Polar Compounds
Increase Your Analytical Confidence For Challenging Polar Compounds Agilent J&W DB-WAX Ultra Inert GC columns Now You Can Achieve Better Peak Shape and Reproducibility for Challenging Polar Compounds GC columns with polyethylene glycol (PEG) stationary phases are commonly used for…
Key words
wax, waxinert, inertultra, ultrainertness, inertnessagilent, agilentltra, ltracolumn, columntightening, tighteningcolumns, columnsnut, nutmau, maupolar, polarplus, plusultimetal, ultimetalglycol
A New PEG GC Column with Improved Inertness Reliability and Column Lifetime
A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column Competitive Comparison Authors Introduction Ngoc-A Dang and Allen K. Vickers Current demanding GC and GC/MS applications have an increased focus…
Key words
wax, waxinertness, inertnessstabilwax, stabilwaxmaltol, maltolactive, activecolumn, columndecanal, decanalmodified, modifiedagilent, agilenttest, testgrob, grobprobes, probesbenchmarking, benchmarkingdicyclohexylamine, dicyclohexylaminesignificant
Agilent Inert Flow Path Solutions - Quick Reference Guide
Quick Reference Guide Agilent Inert Flow Path Solutions Agilent’s 7890B, 8890, and 8860 Inert Flow Path Split/Splitless Inlet option ensures the inertness of flow path surfaces, allowing analytes to safely pass from injector to detector. For best trace level analysis,…
Key words
intuvo, intuvoinert, inertfilm, filmlength, lengthtemp, tempultra, ultralimits, limitsferrule, ferrulegold, goldultimetal, ultimetalagilent, agilentflexible, flexiblemetal, metalwool, woolpath
Detect Every Peak and Minimize Degradative Buildup in Your GC Flow Path - Agilent Inert Flow Path solutions
Detect Every Peak and Minimize Degradative Buildup in Your GC Flow Path Agilent Inert Flow Path solutions Ensuring an Inert Flow Path from Injection Through Detection Is Critical—and Now, Easy to Achieve As regulatory agencies drive limits of detection lower…
Key words
inert, inertagilent, agilentultra, ultrapath, pathliners, linersultimetal, ultimetalplus, plusflow, flowinlet, inletinertness, inertnessdeactivation, deactivationyour, yourmetal, metalflexible, flexiblegold
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike